GÜNIŞIĞI-YAPAY IŞIK ENTEGRASYONUNU SAĞLAYAN IŞIK RAFI SİSTEMİNİN İNCELENMESİ. Duygu ÇETEGEN, Dilek ENARUN, Alpin KÖKNEL YENER, Alp BATMAN

Ebat: px
Şu sayfadan göstermeyi başlat:

Download "GÜNIŞIĞI-YAPAY IŞIK ENTEGRASYONUNU SAĞLAYAN IŞIK RAFI SİSTEMİNİN İNCELENMESİ. Duygu ÇETEGEN, Dilek ENARUN, Alpin KÖKNEL YENER, Alp BATMAN"

Transkript

1 GÜNIŞIĞI-YAPAY IŞIK ENTEGRASYONUNU SAĞLAYAN IŞIK RAFI SİSTEMİNİN İNCELENMESİ Duygu ÇETEGEN, Dilek ENARUN, Alpin KÖKNEL YENER, Alp BATMAN Investigation of the Light Shelf System Accomplishing The Integration of Daylight And Artificial Light Intelligent daylight utilisation in buildings by using innovative daylighting systems in combination with daylight responsive control of electric lighting positively effects both human response and cost evaluation of the lighting system, and increases energy efficiency. In this study, Light Shelf System is examined under the geographical and climatic conditions of Istanbul. Since the sun elevation in Istanbul is high compared with the northern latitudes, and the building, where the Light Shelf System is installed, has a horizontal extension, the amount of daylight entering the offices is limited. In spite of these disadvantages, The Light Shelf System improves the distribution of daylight in the test room. In order to save energy, the artificial light sources in the test room are dimmed by the automatic control system. The investigations indicate that using the Light Shelf System and the automatic control system, the energy savings are 25% in spring and autumn, 19.5% in winter and 11.4% in summer. Anahtar Sözcükler: Aydınlatma, Gelişmiş Doğal Aydınlatma Sistemleri, Işık Rafı Sistemi, Enerji Tasarrufu 1. GİRİŞ İnsanın evrimleşme tarihi incelendiğinde, insanların yerleşik sistemde yapay aydınlatma kullanarak yaşadıkları sürenin, ilk insanlardan günümüze dek geçen süreye oranla oldukça az olduğu görülür. Yerleşik yaşama geçişin sonucu olarak, kalıcı konutlar inşa etmeye başlayan insanoğlu, doğal ışıktan mümkün olduğunca fazla faydalanabileceği şekilde bina yapısını düzenlemiştir. Fenerler, tepe pencereleri kullanılmışlardır. Elektriğin ve yapay ışık kaynaklarının icadının ardından, hacimlerde doğal ışıktan mümkün olduğunca faydalanma özeninden, uzaklaşılmaya başlanmıştır. Yapay ışığın istenen hacimde istenen düzeyde aydınlatma sağlayabilmesinin sonucu olarak, zaman içinde doğal ışığın aydınlatma amacıyla kullanılması neredeyse unutulmuştur. Doğal ışığın insan fizyolojisi ve psikolojine sağladığı olumlu etkiler ve geleceği açıkça görülen enerji krizi sebebiyle, günümüzde doğal aydınlatmaya dönüş yaşanmaktadır. Doğal ışığın yapay ışık ile desteklenerek hacimlerin aydınlatmasında kullanılmasını sağlayan tren istasyonları, ticari binalar, okullar ve iş merkezlerinde uygulanan gelişmiş aydınlatma sistemleri mevcuttur [1,2]. Doğal aydınlatma sistemlerinin, bölgenin coğrafyasına ve iklim koşullarına uygun seçilmesine dikkat edilmelidir. Yerel şartlara uygun olmayan sistemler kullanıldığında, sistemden sağlanacak verim düşük olacaktır. Seçilmiş günışığı sistemleri ve elektronik kontrol sistemlerinin farklı iklim bölgeleri için optimizasyonuna ve geliştirilmelerine ilişkin çalışmalar yapılmaktadır. Bu amaç doğrultusunda, Berlin Teknik Üniversitesi ve Siteco nun katkıları ile İstanbul Teknik Üniversitesinde, Işık Rafı Sistemi (IRS) ve otomatik kontrol düzenekleri ile donatılmış bir deney odası ve karşılaştırma yapabilmek amacıyla bir referans oda tesis edilmiştir. Bu çalışmanın amacı, IRS ve otomatik kontrol sisteminin enerji tasarrufu analizini yapmaktır. Yapılan analizlerde, test odasında şebekeden çekilen güç baz alınmıştır.

2 2. TEST HACİMLERİNİN TANIMLANMASI Deney amacıyla kullanılan referans oda ve test odası bitişik hacimler olup, kuzey enlemi ve doğu boylamında bulunan İTÜ Ayazağa kampüsü Elektrik-Elektronik Fakültesi binasının üçüncü katındadırlar. Hacimler güneyden 10 lik sapma açısıyla güneybatı doğrultusunda yer almaktadırlar. Şekil 1-3 de, şehir merkezi ile çevrelenmiş düz açık alanda bulunan deney hacimlerinin, dış cephe ve iç hacim görüntüleri verilmiştir. Binayı çevreleyen açık alan çimenle kaplı olup, kışın toplam iki haftayı geçmeyen süre boyunca karla kaplanmaktadır. Test odası ve referans oda başlangıçta birbirlerinin aynı iki hacim iken, test odasında tavanın alçaltılması ve pencerelerin üst kısımlarını IRS nin kapatması sonucu, hacimlerin özellikleri farklılaşmıştır. Hacimlerde ölçümler tek noktada yapıldığından ve aydınlık düzeyinin dağılımı incelenmediği için bu durum bu çalışmada herhangi bir sakınca oluşturmamaktadır. Test odası ve referans odanın uzunlukları 7.3 m ve genişlikleri 3.35 m dir. Test odasının yüksekliği 3 m olup, referans odanın yüksekliği, fakülte binasındaki standart hacim yüksekliği olan 4 m dir. Tavan gelişmiş doğal aydınlatma sisteminin bir parçasıdır ve tavanın IRS nin ikincil yansıtıcısı olarak kullanılabilmesi için test odasında tadilat yapılmıştır. Referans oda ve test odasındaki pencere alanları sırasıyla, 3 m 2 ve 1.6 m 2 dir. Şekil 1. Güneye bakan cephenin dış görünüşü

3 Şekil 2. Test odası Şekil 3. Referans oda IRS, pencerelerin üst bölümlerine monte edilen, içerisinde hem doğal ışık yansıtıcılarını hem de yapay ışık kaynaklarını barındıran bir sistemdir. Doğal ışık yansıtıcıları, pencerenin üst bölümünden gelen ışığı tavana yansıtıp, doğal ışığı tavandan hacmin daha derin bölgelerine iletmektedir. Sistemin içinde yer alan yapay ışık kaynaklarının ışıkları da benzer bir yöntemle endirekt olarak çalışma düzlemine erişmektedirler. Amaç, çalışma düzleminde istenen aydınlık düzeyine ulaşmak için, mevcut doğal ışığı, yapay ışık ile desteklemektir. Test odası ve referans odaya ait yansıtma katsayıları ölçülmüştür ve aşağıdaki değerler bulunmuştur. Test odası ve referans odanın beyaz tavan ve duvarlarının yansıtma katsayıları %85 dir. Test odasının zemini açık gri renkli halı ile kaplanmış olup, yansıtma katsayısı %35; referans odanın zeminini kaplayan açık yeşil halının yansıtma katsayısı ise %15 dir. Her iki hacimde de yansıtma katsayıları %18 olan çalışma masaları bulunmaktadır. Test odası ve referans odada kullanılan mobilyaların yansıtma katsayıları sırasıyla, %10-%15 ve %15- %35 arasında değişmektedir.

4 2.1. Yapay Aydınlatma Sistemi Test odasında yapay aydınlatma 4 adet 58 W, 6510 lm lik sıcak beyaz ışık renkli fluoresan lamba ile sağlanmaktadır. Pencereden 2.5 m uzaklıkta ve çalışma düzleminde bulunan ölçme noktasındaki aydınlık düzeyi, doğal ışık olmadığında ve yapay ışık kaynakları tam kapasite ile çalıştıklarında sağlanan 500 lx dür. Referans odadaki yapay aydınlatma 12 adet 40 W lık fluoresan lamba ile sağlanmaktadır. Yapay ışık kaynaklarının referans odada yatay aydınlık düzeyinin ölçüldüğü noktada sağladıkları ortalama aydınlık düzeyi 500 lx dür Ölçme Düzeni Test odasında 4 adet algılayıcı kullanılmıştır. 1 numaralı algılayıcı hacim içinde insan varlığını algılayıp bilgisayara, pencere duvarından 2.5 m uzaklıkta tavana yerleştirilmiş olan 2 numaralı algılayıcı, çalışma düzlemindeki parıltıyı algılayıp, kontrol sistemine iletir. 3 numaralı algılayıcı pencere duvarından 2.5 m uzaklıkta çalışma düzlemine yerleştirilmiştir ve çalışma düzlemindeki aydınlık düzeyini algılayıp bilgisayara iletir. 4 numaralı algılayıcı ise cephedeki düşey aydınlık düzeyi bilgisini bilgisayara ulaştırır. Tüm ölçümler 2 dakikada bir alınmıştır. Referans odada kullanılan 3 adet algılayıcının hepsi verilerini bilgisayara iletmektedirler. Pencere duvarından 2.5 m uzaklığa ve zeminden 3 m yüksekliğe yerleştirilen 5 numaralı algılayıcı, hacimdeki lambaların açık olup olmadıklarını algılayabilmek için, lambalara yakın bir yükseklikteki aydınlık düzeyini ölçer. Çalışma düzleminde pencere duvarından 2.5 m uzaklığa yerleştirilen 6 numaralı algılayıcı ise, çalışma düzlemindeki aydınlık düzeyi ölçümünü yapmaktadır. 7 numaralı algılayıcı hacim içinde insan varlığını algılayıp bilgisayara iletmektedir. Şekil 4. Test odasındaki ölçme düzeneği

5 2.3. Otomatik Kontrol Sistemi Şekil 5. Referans odadaki ölçme düzeneği IRS nin kontrolünde European Instabus Integral Tipi Kontrol Sistemi (EIB) kullanılmıştır. Loşlaştırma birimi loşlaştırma sinyalini 1-10 V arasında alır. Bu sistem bir grup yapay ışık kaynağını tek bir sistem olarak kabul ederek, doğal aydınlık düzeyine göre kontrol sağlar. Bir EIB yazılımı ile programlanır ve kalibrasyonu yapılır. Kontrol sisteminin ışık algılayıcısı filtre edilmiş BPW21R tipi Si-Diyottur [3]. 3. YÖNTEM Bu araştırmada çalışma saatleri 8:00-18:00 arası kabul edilmiştir. İki dakikada bir ölçüm yapılmıştır. Sekiz algılayıcının her birinden alınan veri kullanılmıştır. Toplam veriden hatalı 9900 adet veri kullanılmayıp değerlendirme dışı bırakılmıştır. Referans odada yapay ışık kullanımına ilişkin yapılan incelemelerde aşağıdaki sonuçlar elde edilmiştir. Hacim çalışanlarca kullanılmadığında ve/veya çalışma düzleminde referans aydınlık düzeyi doğal aydınlatma ile sağlanmasına rağmen, yapay aydınlatma kullanılmıştır. Şekil 6 da referans odaya ait, 09/04/2003 tarihli ölçüm sonuçları verilmektedir. Çalışma düzlemindeki doğal ve yapay aydınlık düzeyi, doğal aydınlık düzeyi, hacmin kullanımına ilişkin bilgi, yapay ışık kaynaklarının kullanılma süreleri ve referans aydınlık düzeyi olan 500 lx şekilde grafik halinde verilmiştir. Günün başında çalışma düzlemindeki aydınlık düzeyi 1050 lx olmasına rağmen, ışıklar yakılmış ve ancak akşam mesai bitiminde oda terk edilirken kapatılmışlardır.

6 Şekil 6. Referans oda ölçüm sonuçları, 09/04/2003 Referans oda ile test odası enerji kullanımı bakımından karşılaştırılırken, referans oda çalışma düzlemindeki doğal aydınlık düzeyi 500 lx den az olduğunda yapay ışık kullanılacağı varsayımı yapılmıştır. Böyle bir varsayım yapılmasının birden fazla nedeni vardır. Örneğin üniversitemizde çalışan kişiler sıklıkla doğal aydınlatmadan kaynaklanan aydınlık düzeyine dikkat etmeden, sabahleyin odaya girdiklerinde ışıkları açmaktalar ve bu ışıklar akşam oda terk edilene kadar açık kalmaktadırlar. Ayrıca, referans odada çalışan kişiler bir laboratuarda da çalışmak mecburiyetinde olduklarından, bazı günler odayı kimse kullanmamaktadır. Referans odada yapay aydınlatma için, 40W +9 W gücünde 12 adet fluoresan lamba kullanılmaktadır. Referans odada şebekeden çekilmesi muhtemel enerji Wh cinsinden hesaplanmıştır. Test odasında lambaların kontrol gerilimleri ölçülmektedir. Kontrol gerilimi ile şebekeden çekilen güç arasında lineer kabul edilebilecek bir bağıntı mevcuttur. 10 V luk kontrol gerilimi şebekeden çekilen 360 W a karşılık gelmektedir. Bu bilgiden yola çıkılarak, test odasında sistemin harcadığı enerji Wh cinsinden hesaplanmıştır. Şekil 7. Kontrol sisteminin standart loşlaştırma eğrisi, şebekeden çekilen bağıl güce karşılık ışık kaynaklarının verdiği bağıl ışık akısı [3]

7 3. DENEY SONUÇLARI VE DEĞERLENDİRİLMESİ Yapılan incelemeler sonucu elde edilen sonuçlar Şekil 8 de verilmiştir. Referans odaya ilişkin değerler siyah, test odasına ait değerler gri çubuklarla gösterilmiştir. Tablo 1 ve 2 de verilen 10, 11, 12. ay verileri 2002 yılına, 1-9 aylarının verileri 2003 yılına aittirler. Aralık ayına ait 15 günlük veri, ayın diğer yarısında benzer değerler beklendiği için tüm aya tamamlanmıştır. Tablo 1 ve 2 de verilen referans odaya ait değerler, referans odada aydınlatma için yapılan varsayım altında, harcanması öngörülen aylık toplam enerji miktarlarıdır. Test odası değerleri, test odasında aydınlatma amacıyla harcanan aylık toplam enerji miktarlarıdır. Tasarruf olarak ifade edilen oran, test odasındaki sistemin, referans odaya göre sağladığı enerji tasarrufudur [4]. Tablo 1. Referans oda ve test odasına ait enerji değerleri, yılın ilk altı ayı için, Wh cinsinden [4] referans oda test odası tasarruf [%] Tablo 2. Referans oda ve test odasına ait enerji değerleri, yılın ikinci altı için, Wh cinsinden [4] referans oda test odası tasarruf [%] Tablo 3. Mevsimlere göre ve yıllık ortalama % cinsinden tasarruf oranları [4] bahar ayları 25 kış ayları 19.5 yaz ayları 11.4 yıllık 20.4 referans odaya ait olacağı kabul edilen ve test odasına ait şebekeden çekilen enerji (Wh) enerji (Wh) ay Şekil 8. Referans oda ve test odasına ait enerji değerleri [4]

8 4. SONUÇLAR Bu çalışmada, Berlin Teknik Üniversitesi Işık Tekniği Enstitüsü ve Siteco Beleuchtungstechnik GmbH ile birlikte İTÜ Elektrik-Elektronik Fakültesi tarafından ortaklaşa yürütülen Işık Rafı Sistemi ile Günışığı-Yapay Işık Entegrasyonunun İklim Koşullarına Bağlı Optimizasyonu isimli araştırma projesinin bir bölümü konusunda bilgi verilmiştir. Buradan elde edilen sonuçlar tartışılmıştır. İstanbul Teknik Üniversitesi nde kurulu sistem incelendiğinde, pencerenin üzerinde dışarıya doğru geniş çıkıntıların olması durumunda, hacme giren doğal ışık miktarının kısıtlandığı görülmektedir. Bunun nedeni üzerinde bulunduğumuz enlemde güneş yükseklik açısının kuzey enlemlerine nazaran daha büyük olmasıdır. Bu sakıncaya rağmen IRS hacimdeki doğal ışık dağılımını düzenlemektedir ve doğal ışığın kullanım verimini arttırmaktadır. IRS nin hacmin doğal aydınlatmasına katkılarının yanında, kullanılan otomatik kontrol sistemi ile, istenen aydınlık düzeyi olan 500 lx değerine günışığı ile ulaşılabildiğinde, ışık kaynaklarının loşlaştırılmaları sağlanarak, enerji tasarrufu elde edilmektedir. Referans oda ve test odasından toplanan verilerin incelenmesi sonucunda, Işık Rafı Sistemi ile Günışığı Yapay Işık Entegrasyon Sisteminin kullanımı ile bahar aylarında % 25, kış aylarında % 19.5, yaz aylarında % 11.4 olmak üzere, yıllık ortalama % 20 oranında tasarruf sağlandığı görülmüştür. 5. KAYNAKLAR [1] Daylight in Buildings, A Source Book on Daylighting Systems and Components, A Report of IEA SHC Task 21 / ECBCS ANNEX 29, July 2000 [2] Çetegen D, Enarun D, Doğal aydınlatma konusundaki yeniliklere bir bakış, 3. Ulusal Aydınlatma Kongresi, İstanbul, sayfa 30-35, Kasım 2000 [3] BELENDORF Heiko, Fortschritt-Berichte der VDI Zeitschriften, 2003 [4] ÇETEGEN Duygu, Doğal Işığın Hacim İçinde Etkin Kullanımını Sağlayan Düzeneklerin İstanbul İklim Koşulları Altında İncelenmesi, Yüksek Lisans Tezi, İ.T.Ü. Fen Bilimleri Enstitüsü, İstanbul, Ocak 2004 Teşekkür Bu çalışma, Berlin Teknik Üniversitesi Işık Tekniği Enstitüsü ile İTÜ Elektrik-Elektronik Fakültesi nin ortaklaşa yürüttükleri Işık Rafı Sistemi ile Günışığı-Yapay Işık Entegrasyonunun İklim Koşullarına Bağlı Optimizasyonu isimli araştırma projesi kapsamında, SİTECO Beleuchtungstechnik GmbH firması ve İTÜ Araştırma Fonu tarafından desteklenmiştir. Odalarını deneylerimizin yürütülebilmesi amacıyla kullanımımıza açan Prof.Dr. Serhat ŞEKER, Y.Doç.Dr. Emine AYAZ, Öğr.Gör.Dr. Ramazan ÇAĞLAR a ve test odasının tadilatının yapılmasının yanısıra bize her konuda destek olarak bu çalışmanın yapılmasına olanak sağlayan SİTECO Aydınlatma Tekniği Ticaret ve Sanayi Ltd. Şirketi ne en içten teşekkürlerimizi sunarız. Duygu ÇETEGEN 1), Dilek ENARUN 2), Alp BATMAN 4) İstanbul Teknik Üniversitesi, Elektrik- Elektronik Fakültesi, 34469, Maslak, İstanbul 1) Tel: e-posta: dcetegen@elk.itu.edu.tr 2) Tel: e-posta: dilek@elk.itu.edu.tr 4) Tel: e-posta: batman@elk.itu.edu.tr Fax: Alpin KÖKNEL YENER 3) İstanbul Teknik Üniversitesi, Mimarlık Fakültesi, Taşkışla, 34437, Taksim, İstanbul. Tel: / Faks: e-posta: alpin.yener@itu.edu.tr

BİNALARDA AYDINLATMA ENERJİSİ PERFORMANSININ BELİRLENMESİNDE YÖREYE İLİŞKİN ÖZELLİKLERİN ROLÜ

BİNALARDA AYDINLATMA ENERJİSİ PERFORMANSININ BELİRLENMESİNDE YÖREYE İLİŞKİN ÖZELLİKLERİN ROLÜ BİNALARDA AYDINLATMA ENERJİSİ PERFORMANSININ BELİRLENMESİNDE YÖREYE İLİŞKİN ÖZELLİKLERİN ROLÜ Feride ŞENER 1, Sezen YILDIRIM ÜNNÜ 2, Alpin KÖKNEL YENER 1 1 İTÜ Mimarlık Fakültesi Taşkışla, Taksim, İstanbul,

Detaylı

BİNALARDA AYDINLATMA ENERJİSİ PERFORMANSININ BELİRLENMESİNDE KONTROL SİSTEMLERİNİN ROLÜ

BİNALARDA AYDINLATMA ENERJİSİ PERFORMANSININ BELİRLENMESİNDE KONTROL SİSTEMLERİNİN ROLÜ BİNALARDA AYDINLATMA ENERJİSİ PERFORMANSININ BELİRLENMESİNDE KONTROL SİSTEMLERİNİN ROLÜ Sezen YILDIRIM ÜNNÜ 1 Feride ŞENER 2 Alpin KÖKNEL YENER 2 1 İTÜ Elektrik Elektronik Fakültesi Ayazağa Kampüsü, İstanbul,

Detaylı

LED PANEL ARMATÜRLERİN OFİS AYDINLATMASINDA RETROFİT AMAÇLI KULLANIMININ İNCELENMESİ

LED PANEL ARMATÜRLERİN OFİS AYDINLATMASINDA RETROFİT AMAÇLI KULLANIMININ İNCELENMESİ LED PANEL ARMATÜRLERİN OFİS AYDINLATMASINDA RETROFİT AMAÇLI KULLANIMININ İNCELENMESİ Emre ERKİN M. Berker YURTSEVEN Önder GÜLER Sermin ONAYGİL erkinem@itu.edu.tr byurtseven@itu.edu.tr onder.guler@itu.edu.tr

Detaylı

ORTADOĞU TEKNİK ÜNİVERSİTESİ MİMARLIK FAKÜLTESİ MİMARLIK EĞİTİM ATÖLYELERİNİN DOĞAL AYDINLATMA AÇISINDAN İNCELENMESİ VE DEĞERLENDİRİLMESİ

ORTADOĞU TEKNİK ÜNİVERSİTESİ MİMARLIK FAKÜLTESİ MİMARLIK EĞİTİM ATÖLYELERİNİN DOĞAL AYDINLATMA AÇISINDAN İNCELENMESİ VE DEĞERLENDİRİLMESİ ORTADOĞU TEKNİK ÜNİVERSİTESİ MİMARLIK FAKÜLTESİ MİMARLIK EĞİTİM ATÖLYELERİNİN DOĞAL AYDINLATMA AÇISINDAN İNCELENMESİ VE DEĞERLENDİRİLMESİ Cüneyt KURTAY, Bașak ERÇALIK, Mahmut DERVİȘOĞLU, Güldane YILDIZ,

Detaylı

BEP HESAPLAMA YÖNTEMİ REFERANS BİNA, ORANLAR, DÖNÜŞÜM KATSAYILARI ve ENERJİ KİMLİK BELGESİ

BEP HESAPLAMA YÖNTEMİ REFERANS BİNA, ORANLAR, DÖNÜŞÜM KATSAYILARI ve ENERJİ KİMLİK BELGESİ BEP HESAPLAMA YÖNTEMİ REFERANS BİNA, ORANLAR, DÖNÜŞÜM KATSAYILARI ve ENERJİ KİMLİK BELGESİ Murat BAYRAM Mak.Yük.Müh. Şb.Müd.V. B.İ.B. Yapı İşleri Genel Müdürlüğü Binalarda Enerji Verimliliği Şube Müdürlüğü

Detaylı

BİNALARDA AYDINLATMA ENERJİSİ PERFORMANSININ BELİRLENMESİ İÇİN BİR YÖNTEM: BEP-TR

BİNALARDA AYDINLATMA ENERJİSİ PERFORMANSININ BELİRLENMESİ İÇİN BİR YÖNTEM: BEP-TR 829 BİNALARDA AYDINLATMA ENERJİSİ PERFORMANSININ BELİRLENMESİ İÇİN BİR YÖNTEM: BEP-TR Alpin Köknel YENER ÖZET Binalarda Enerji Performansı Yönetmeliği (2002/91/EC), Avrupa Birliği ülkelerinde binaların

Detaylı

YAPI FİZİĞİ UZMANLIK UYGULAMALARI

YAPI FİZİĞİ UZMANLIK UYGULAMALARI YAPI FİZİĞİ UZMANLIK UYGULAMALARI San. ve Tic. A.Ş. Vefabayırı Sok. No.38, 34349 Istanbul-TURKEY - Tel.:+90 212 275 3588, Fax: +90 212 267 3962, e-mail: yfu@yfu.com GONYOFOTOMETRİK ÖLÇME RAPORU Firma Luxar

Detaylı

YAPI FİZİĞİ UZMANLIK UYGULAMALARI

YAPI FİZİĞİ UZMANLIK UYGULAMALARI YAPI FİZİĞİ UZMANLIK UYGULAMALARI San. ve Tic. A.Ş. Vefabayırı Sok. No.38, 34349 Istanbul-TURKEY - Tel.:+90 212 275 3588, Fax: +90 212 267 3962, e-mail: yfu@yfu.com GONYOFOTOMETRİK ÖLÇME RAPORU Firma A101

Detaylı

ENDÜSTRİYEL TESİSLERDE AYDINLATMA UYGULAMALARI

ENDÜSTRİYEL TESİSLERDE AYDINLATMA UYGULAMALARI ENDÜSTRİYEL TESİSLERDE AYDINLATMA UYGULAMALARI Tuba BOSTANCI BASKAN Türk Philips Tic. A.Ş. Saray mah. Dr.Adnan Büyükdeniz Cad. No:13, Ümraniye, İstanbul. Tel: 0-216-636 18 62 Faks: 0-216-636 18 35 e-mail:

Detaylı

YAPI FİZİĞİ UZMANLIK UYGULAMALARI

YAPI FİZİĞİ UZMANLIK UYGULAMALARI YAPI FİZİĞİ UZMANLIK UYGULAMALARI San. ve Tic. A.Ş. Vefabayırı Sok. No.38, 34349 Istanbul-TURKEY - Tel.:+90 212 275 3588, Fax: +90 212 267 3962, e-mail: yfu@yfu.com GONYOFOTOMETRİK ÖLÇME RAPORU Firma LİTPA

Detaylı

YAPI FİZİĞİ UZMANLIK UYGULAMALARI

YAPI FİZİĞİ UZMANLIK UYGULAMALARI YAPI FİZİĞİ UZMANLIK UYGULAMALARI San. ve Tic. A.Ş. Vefabayırı Sok. No.38, 34349 Istanbul-TURKEY - Tel.:+90 212 275 3588, Fax: +90 212 267 3962, e-mail: yfu@yfu.com GONYOFOTOMETRİK ÖLÇME RAPORU Firma LİTPA

Detaylı

YAPI FİZİĞİ UZMANLIK UYGULAMALARI

YAPI FİZİĞİ UZMANLIK UYGULAMALARI YAPI FİZİĞİ UZMANLIK UYGULAMALARI San. ve Tic. A.Ş. Vefabayırı Sok. No.38, 34349 Istanbul-TURKEY - Tel.:+90 212 275 3588, Fax: +90 212 267 3962, e-mail: yfu@yfu.com GONYOFOTOMETRİK ÖLÇME RAPORU Firma LİTPA

Detaylı

YAPI FİZİĞİ UZMANLIK UYGULAMALARI

YAPI FİZİĞİ UZMANLIK UYGULAMALARI YAPI FİZİĞİ UZMANLIK UYGULAMALARI San. ve Tic. A.Ş. Vefabayırı Sok. No.38, 34349 Istanbul-TURKEY - Tel.:+90 212 275 3588, Fax: +90 212 267 3962, e-mail: yfu@yfu.com GONYOFOTOMETRİK ÖLÇME RAPORU Firma LİTPA

Detaylı

YAPI FİZİĞİ UZMANLIK UYGULAMALARI

YAPI FİZİĞİ UZMANLIK UYGULAMALARI YAPI FİZİĞİ UZMANLIK UYGULAMALARI San. ve Tic. A.Ş. Vefabayırı Sok. No.38, 34349 Istanbul-TURKEY - Tel.:+90 212 275 3588, Fax: +90 212 267 3962, e-mail: yfu@yfu.com GONYOFOTOMETRİK ÖLÇME RAPORU Firma LİTPA

Detaylı

YAPI FİZİĞİ UZMANLIK UYGULAMALARI

YAPI FİZİĞİ UZMANLIK UYGULAMALARI YAPI FİZİĞİ UZMANLIK UYGULAMALARI San. ve Tic. A.Ş. Vefabayırı Sok. No.38, 34349 Istanbul-TURKEY - Tel.:+90 212 275 3588, Fax: +90 212 267 3962, e-mail: yfu@yfu.com GONYOFOTOMETRİK ÖLÇME RAPORU Firma LİTPA

Detaylı

YAPI FİZİĞİ UZMANLIK UYGULAMALARI

YAPI FİZİĞİ UZMANLIK UYGULAMALARI YAPI FİZİĞİ UZMANLIK UYGULAMALARI San. ve Tic. A.Ş. Vefabayırı Sok. No.38, 34349 Istanbul-TURKEY - Tel.:+90 212 275 3588, Fax: +90 212 267 3962, e-mail: yfu@yfu.com GONYOFOTOMETRİK ÖLÇME RAPORU Firma LİTPA

Detaylı

YAPI FİZİĞİ UZMANLIK UYGULAMALARI

YAPI FİZİĞİ UZMANLIK UYGULAMALARI YAPI FİZİĞİ UZMANLIK UYGULAMALARI San. ve Tic. A.Ş. Vefabayırı Sok. No.38, 34349 Istanbul-TURKEY - Tel.:+90 212 275 3588, Fax: +90 212 267 3962, e-mail: yfu@yfu.com GONYOFOTOMETRİK ÖLÇME RAPORU Firma LİTPA

Detaylı

YAPI FİZİĞİ UZMANLIK UYGULAMALARI

YAPI FİZİĞİ UZMANLIK UYGULAMALARI YAPI FİZİĞİ UZMANLIK UYGULAMALARI San. ve Tic. A.Ş. Vefabayırı Sok. No.38, 34349 Istanbul-TURKEY - Tel.:+90 212 275 3588, Fax: +90 212 267 3962, e-mail: yfu@yfu.com GONYOFOTOMETRİK ÖLÇME RAPORU Firma LİTPA

Detaylı

Aydınlatma Programlarının Enerji Değerlendirme Özelliklerinin Karşılaştırması

Aydınlatma Programlarının Enerji Değerlendirme Özelliklerinin Karşılaştırması Aydınlatma Programlarının Enerji Değerlendirme Özelliklerinin Karşılaştırması Arzu Cilasun, Yaşar Üniversitesi Mimarlık Fakültesi Leyla Dokuzer Öztürk, YTÜ Mimarlık Fakültesi 1. Giriş Sanayileşmenin hız

Detaylı

OFİSLERDE ENERJİ ETKİN AYDINLATMA SİSTEMLERİ

OFİSLERDE ENERJİ ETKİN AYDINLATMA SİSTEMLERİ OFİSLERDE ENERJİ ETKİN AYDINLATMA SİSTEMLERİ Rana KUTLU * ÖZET Bu çalışmada, konfor koşullarının sağlanmasında ve mekanın algılanmasında mimarinin önemli öğelerinden biri olan aydınlatma konusu; enerji

Detaylı

T.C. MİLLİ EĞİTİM BAKANLIĞI TÜBİTAK- BİDEB YİBO ÖĞRETMENLERİ (FİZİK) PROJE DANIŞMANLIĞI EĞİTİMİ ÇALIŞTAYI ÇALIŞTAY 2009-2

T.C. MİLLİ EĞİTİM BAKANLIĞI TÜBİTAK- BİDEB YİBO ÖĞRETMENLERİ (FİZİK) PROJE DANIŞMANLIĞI EĞİTİMİ ÇALIŞTAYI ÇALIŞTAY 2009-2 T.C. MİLLİ EĞİTİM BAKANLIĞI TÜBİTAK- BİDEB YİBO ÖĞRETMENLERİ (FİZİK) PROJE DANIŞMANLIĞI EĞİTİMİ ÇALIŞTAYI ÇALIŞTAY 29-2 PROJE ADI: KUZEY CEPHELİ EVLERDE GÜNEŞ IŞIĞINDAN DOĞRUDAN FAYDALANMAĞINDAN DOĞRUDAN

Detaylı

YAPI FİZİĞİ UZMANLIK UYGULAMALARI

YAPI FİZİĞİ UZMANLIK UYGULAMALARI YAPI FİZİĞİ UZMANLIK UYGULAMALARI San. ve Tic. A.Ş. Vefabayırı Sok. No.38, 34349 Istanbul-TURKEY - Tel.:+90 212 275 3588, Fax: +90 212 267 3962, e-mail: yfu@yfu.com GONYOFOTOMETRİK ÖLÇME RAPORU Firma LİTPA

Detaylı

YAPI FİZİĞİ UZMANLIK UYGULAMALARI

YAPI FİZİĞİ UZMANLIK UYGULAMALARI YAPI FİZİĞİ UZMANLIK UYGULAMALARI San. ve Tic. A.Ş. Vefabayırı Sok. No.38, 34349 Istanbul-TURKEY - Tel.:+90 212 275 3588, Fax: +90 212 267 3962, e-mail: yfu@yfu.com GONYOFOTOMETRİK ÖLÇME RAPORU Firma LITPA

Detaylı

YAPI FİZİĞİ UZMANLIK UYGULAMALARI

YAPI FİZİĞİ UZMANLIK UYGULAMALARI YAPI FİZİĞİ UZMANLIK UYGULAMALARI San. ve Tic. A.Ş. Vefabayırı Sok. No.38, 34349 Istanbul-TURKEY - Tel.:+90 212 275 3588, Fax: +90 212 267 3962, e-mail: yfu@yfu.com GONYOFOTOMETRİK ÖLÇME RAPORU Firma LİTPA

Detaylı

YAPI FİZİĞİ UZMANLIK UYGULAMALARI

YAPI FİZİĞİ UZMANLIK UYGULAMALARI YAPI FİZİĞİ UZMANLIK UYGULAMALARI San. ve Tic. A.Ş. Vefabayırı Sok. No.38, 34349 Istanbul-TURKEY - Tel.:+90 212 275 3588, Fax: +90 212 267 3962, e-mail: yfu@yfu.com GONYOFOTOMETRİK ÖLÇME RAPORU Firma LİTPA

Detaylı

YAPI FİZİĞİ UZMANLIK UYGULAMALARI

YAPI FİZİĞİ UZMANLIK UYGULAMALARI YAPI FİZİĞİ UZMANLIK UYGULAMALARI San. ve Tic. A.Ş. Vefabayırı Sok. No.38, 34349 Istanbul-TURKEY - Tel.:+90 212 275 3588, Fax: +90 212 267 3962, e-mail: yfu@yfu.com GONYOFOTOMETRİK ÖLÇME RAPORU Firma LİTPA

Detaylı

DİYARBAKIR TARİHİ EVLERİNİN DOĞAL AYDINLATMA AÇISINDAN DEĞERLENDİRİLMESİ

DİYARBAKIR TARİHİ EVLERİNİN DOĞAL AYDINLATMA AÇISINDAN DEĞERLENDİRİLMESİ DİYARBAKIR TARİHİ EVLERİNİN DOĞAL AYDINLATMA AÇISINDAN DEĞERLENDİRİLMESİ Diyarbakır Proje Merkezi (DPM) Evi Örneği Özgür Murt, F. Demet AYKAL, Bilal GÜMÜŞ, Rengin ÜNVER Hacimdeki eylemlere bağlı olarak,

Detaylı

YAPI FİZİĞİ UZMANLIK UYGULAMALARI

YAPI FİZİĞİ UZMANLIK UYGULAMALARI YAPI FİZİĞİ UZMANLIK UYGULAMALARI San. ve Tic. A.Ş. Vefabayırı Sok. No.38, 34349 Istanbul-TURKEY - Tel.:+90 212 275 3588, Fax: +90 212 267 3962, e-mail: yfu@yfu.com GONYOFOTOMETRİK ÖLÇME RAPORU Firma LİTPA

Detaylı

YAPI FİZİĞİ UZMANLIK UYGULAMALARI

YAPI FİZİĞİ UZMANLIK UYGULAMALARI YAPI FİZİĞİ UZMANLIK UYGULAMALARI San. ve Tic. A.Ş. Vefabayırı Sok. No.38, 34349 Istanbul-TURKEY - Tel.:+90 212 275 3588, Fax: +90 212 267 3962, e-mail: yfu@yfu.com GONYOFOTOMETRİK ÖLÇME RAPORU Firma LİTPA

Detaylı

YAPI FİZİĞİ UZMANLIK UYGULAMALARI

YAPI FİZİĞİ UZMANLIK UYGULAMALARI YAPI FİZİĞİ UZMANLIK UYGULAMALARI San. ve Tic. A.Ş. Vefabayırı Sok. No.38, 34349 Istanbul-TURKEY - Tel.:+90 212 275 3588, Fax: +90 212 267 3962, e-mail: yfu@yfu.com GONYOFOTOMETRİK ÖLÇME RAPORU Firma LİTPA

Detaylı

YAPI FİZİĞİ UZMANLIK UYGULAMALARI

YAPI FİZİĞİ UZMANLIK UYGULAMALARI YAPI FİZİĞİ UZMANLIK UYGULAMALARI San. ve Tic. A.Ş. Vefabayırı Sok. No.38, 34349 Istanbul-TURKEY - Tel.:+ 212 275 3588, Fax: + 212 267 3962, e-mail: yfu@yfu.com GONYOFOTOMETRİK ÖLÇME RAPORU Firma LİTPA

Detaylı

YAPI FİZİĞİ UZMANLIK UYGULAMALARI

YAPI FİZİĞİ UZMANLIK UYGULAMALARI YAPI FİZİĞİ UZMANLIK UYGULAMALARI San. ve Tic. A.Ş. Vefabayırı Sok. No.38, 34349 Istanbul-TURKEY - Tel.:+90 212 275 3588, Fax: +90 212 267 3962, e-mail: yfu@yfu.com GONYOFOTOMETRİK ÖLÇME RAPORU Firma YFU

Detaylı

YAPI FİZİĞİ UZMANLIK UYGULAMALARI

YAPI FİZİĞİ UZMANLIK UYGULAMALARI YAPI FİZİĞİ UZMANLIK UYGULAMALARI San. ve Tic. A.Ş. Vefabayırı Sok. No., Istanbul-TURKEY - Tel.:+0 1, Fax: +0 1, e-mail: yfu@yfu.com GONYOFOTOMETRİK ÖLÇME RAPORU Firma LİTPA Yapımcı LITPA Işıklık Adı /

Detaylı

KONUTLARDA LAMBA SEÇİMİNİN ENERJİ PERFORMANSI AÇISINDAN DEĞERLENDİRİLMESİ

KONUTLARDA LAMBA SEÇİMİNİN ENERJİ PERFORMANSI AÇISINDAN DEĞERLENDİRİLMESİ KONUTLARDA LAMBA SEÇİMİNİN ENERJİ PERFORMANSI AÇISINDAN DEĞERLENDİRİLMESİ Özlem SÜMENGEN 1 Alpin Köknel YENER 2 1 ERÜ Mimarlık Fakültesi Melikgazi Kayseri, 38030 osumengen@hotmail.com 2 İTÜ Mimarlık Fakültesi

Detaylı

Öz Enerji kaynaklarının bilinçli tüketimi, çevreye duyarlı tasarım ve sürdürülebilirlik kavramlarının

Öz Enerji kaynaklarının bilinçli tüketimi, çevreye duyarlı tasarım ve sürdürülebilirlik kavramlarının 138 Eğitim Yapılarında Enerji Etkin Aydınlatma: İstanbul Kağıthane Anadolu Lisesi Örneği Nihan Gürel Ulusan Doğuş Üniversitesi, Sanat ve Tasarım Fakültesi, Mimarlık Bölümü İpek Fitöz Mimar Sinan Güzel

Detaylı

Binalarda Aydınlatma Enerji Performansının Belirlenmesinde Günışığına İlişkin Değişkenlerin İncelenmesi

Binalarda Aydınlatma Enerji Performansının Belirlenmesinde Günışığına İlişkin Değişkenlerin İncelenmesi 135 Binalarda Aydınlatma Enerji Performansının Belirlenmesinde Günışığına İlişkin Değişkenlerin İncelenmesi Özlem SÜMENGEN 1, Alpin K.YENER 2 1 Erciyes üniversitesi, Mimarlık Fakültesi. Mimarlık Bölümü,

Detaylı

BİNALARDA AYDINLATMA ENERJİSİ PERFORMANSININ BEP-TR YÖNTEMİ İLE BELİRLENMESİ: ÖRNEKLER

BİNALARDA AYDINLATMA ENERJİSİ PERFORMANSININ BEP-TR YÖNTEMİ İLE BELİRLENMESİ: ÖRNEKLER 839 BİNALARDA AYDINLATMA ENERJİSİ PERFORMANSININ BEP-TR YÖNTEMİ İLE BELİRLENMESİ: ÖRNEKLER Feride ŞENER Sezen YILDIRIM ÜNNÜ ÖZET Binalarda aydınlatma enerjisi performansı, mekanlarda istenen görsel konfor

Detaylı

Binalarda Isı Yalıtımı ile Güneş Kontrolünün Önemi

Binalarda Isı Yalıtımı ile Güneş Kontrolünün Önemi Binalarda Isı Yalıtımı ile Güneş Kontrolünün Önemi Dünyamızda milyarlarca yıl boyunca oluşan fosil yakıt rezervleri; endüstri devriminin sonucu olarak özellikle 19.uncu yüzyılın ikinci yarısından itibaren

Detaylı

YAPI DIȘI ENGELLER VE HACİM İÇİ DOĞAL AYDINLIK İLİȘKİSİ ÜZERİNE BİR İNCELEME

YAPI DIȘI ENGELLER VE HACİM İÇİ DOĞAL AYDINLIK İLİȘKİSİ ÜZERİNE BİR İNCELEME YAPI DIȘI ENGELLER VE HACİM İÇİ DOĞAL AYDINLIK İLİȘKİSİ ÜZERİNE BİR İNCELEME Rengin ÜNVER Yapı Fiziği Bilim Dalı Mimarlık Fakültesi Yıldız Teknik Üniversitesi, 34349 Beșiktaș İstanbul e-posta: runver@yildiz.edu.tr

Detaylı

AYDINLATMA TASARIM SÜRECĐNDE VIVALDI VE ECOCALC PROGRAMLARININ KULLANIMI. Arzu CILASUN, Leyla DOKUZER ÖZTÜRK

AYDINLATMA TASARIM SÜRECĐNDE VIVALDI VE ECOCALC PROGRAMLARININ KULLANIMI. Arzu CILASUN, Leyla DOKUZER ÖZTÜRK AYDINLATMA TASARIM SÜRECĐNDE VIVALDI VE ECOCALC PROGRAMLARININ KULLANIMI Arzu CĐLASUN, Leyla DOKUZER ÖZTÜRK Use of VIVALDI and ECOCALC Programs in Lighting Design Process The contribution points out the

Detaylı

MAK-LAB009 DOĞAL VE ZORLANMIġ TAġINIM YOLUYLA ISI TRANSFERĠ DENEYĠ

MAK-LAB009 DOĞAL VE ZORLANMIġ TAġINIM YOLUYLA ISI TRANSFERĠ DENEYĠ MAK-LAB009 DOĞAL VE ZORLANMIġ TAġINIM YOLUYLA ISI TRANSFERĠ DENEYĠ 1. GĠRĠġ Endüstride kullanılan birçok ısı değiştiricisi ve benzeri cihazda ısı geçiş mekanizması olarak ısı iletimi ve taşınım beraberce

Detaylı

DERSLİKLERDE GELENEKSEL İLE LED AYDINLATMA SİSTEMLERİNİN KARŞILAŞTIRILMASI

DERSLİKLERDE GELENEKSEL İLE LED AYDINLATMA SİSTEMLERİNİN KARŞILAŞTIRILMASI DERSLİKLERDE GELENEKSEL İLE LED AYDINLATMA SİSTEMLERİNİN KARŞILAŞTIRILMASI Tuba BOSTANCI BASKAN Türk Philips Tic. A.Ş. Saray mah. Dr.Adnan Büyükdeniz Cad. No:13, Ümraniye, İstanbul. Tel: 0-216-636 18 62

Detaylı

TİP İLKOKUL DERSLİKLERİNİN GÜN IŞIĞINDAN ETKİN YARARLANMASINA YÖNELİK BİR ÇALIŞMA

TİP İLKOKUL DERSLİKLERİNİN GÜN IŞIĞINDAN ETKİN YARARLANMASINA YÖNELİK BİR ÇALIŞMA TİP İLKOKUL DERSLİKLERİNİN GÜN IŞIĞINDAN ETKİN YARARLANMASINA YÖNELİK BİR ÇALIŞMA Yasemin DURALER 1, Alpin Köknel YENER 2 Mimarlık Fakültesi Mimarlık Bölümü İstanbul Teknik Üniversitesi İstanbul-Türkiye

Detaylı

DERSLĐKLERDE GÖRSEL KONFOR VE OPTĐMUM ENERJĐ KULLANIMI ĐÇĐN FARKLI AYDINLATMA DÜZENLERĐNĐN KARŞILAŞTIRILMASI

DERSLĐKLERDE GÖRSEL KONFOR VE OPTĐMUM ENERJĐ KULLANIMI ĐÇĐN FARKLI AYDINLATMA DÜZENLERĐNĐN KARŞILAŞTIRILMASI DERSLĐKLERDE GÖRSEL KONFOR VE OPTĐMUM ENERJĐ KULLANIMI ĐÇĐN FARKLI AYDINLATMA DÜZENLERĐNĐN KARŞILAŞTIRILMASI Tuba BOSTANCI BASKAN Müjgan ŞEREFHANOĞLU SÖZEN Türk Philips Tic. A.Ş. Yıldız Teknik Üniversitesi

Detaylı

19 ve 29 cmlik PONCEBLOC HAFİF YAPI ELEMANI SES AZALMA İNDİSİ ÖLÇÜMÜ ÖN RAPORU

19 ve 29 cmlik PONCEBLOC HAFİF YAPI ELEMANI SES AZALMA İNDİSİ ÖLÇÜMÜ ÖN RAPORU 19 ve 29 cmlik PONCEBLOC HAFİF YAPI ELEMANI SES AZALMA İNDİSİ ÖLÇÜMÜ ÖN RAPORU HAZIRLAYAN : Y.DOÇ. DR. NURGÜN TAMER BAYAZIT İTÜ MİMARLIK FAKÜLTESİ YAPI BİLGİSİ ABD TAŞKIŞLA TAKSİM-34437 İST TEMMUZ, 2014

Detaylı

Binalarda Isı Yalıtımı ile Güneş Kontrolünün Önemi

Binalarda Isı Yalıtımı ile Güneş Kontrolünün Önemi Binalarda Isı Yalıtımı ile Güneş Kontrolünün Önemi Dünyamızda milyarlarca yıl boyunca oluşan fosil yakıt rezervleri; endüstri devriminin sonucu olarak özellikle 19.uncu yüzyılın ikinci yarısından itibaren

Detaylı

DENEY 3. Maksimum Güç Transferi

DENEY 3. Maksimum Güç Transferi ULUDAĞ ÜNİVERSİTESİ MÜHENDİSLİK FAKÜLTESİ ELEKTRİK-ELEKTRONİK MÜHENDİSLİĞİ BÖLÜMÜ ELN2024 Elektrik Devreleri Laboratuarı II 2013-2014 Bahar DENEY 3 Maksimum Güç Transferi Deneyi Yapanın Değerlendirme Adı

Detaylı

Termodinamik. Öğretim Görevlisi Prof. Dr. Lütfullah Kuddusi. Bölüm 2 Problemler. Problem numaraları kitabın «5 th Edition» ile aynıdır.

Termodinamik. Öğretim Görevlisi Prof. Dr. Lütfullah Kuddusi. Bölüm 2 Problemler. Problem numaraları kitabın «5 th Edition» ile aynıdır. Termodinamik Öğretim Görevlisi Prof. Dr. Lütfullah Kuddusi Bölüm 2 Problemler Problem numaraları kitabın «5 th Edition» ile aynıdır. 1 2-26 800 kg kütlesi olan bir arabanın yatay yolda 0 dan 100 km/h hıza

Detaylı

CEPHE TASARIMININ İÇ MEKÂN GÜNIŞIĞI PERFORMANSINA ETKİSİNİN BELİRLENMESİ

CEPHE TASARIMININ İÇ MEKÂN GÜNIŞIĞI PERFORMANSINA ETKİSİNİN BELİRLENMESİ 9. Ulusal Çatı & Cephe Konferansı 12-13 Nisan 2018 T.C. İstanbul Kültür Üniversitesi Ataköy Yerleşkesi Akıngüç Oditoryumu CEPHE TASARIMININ İÇ MEKÂN GÜNIŞIĞI PERFORMANSINA ETKİSİNİN BELİRLENMESİ Z. Aybike

Detaylı

AYNA ÖNÜ AYDINLATMASI İLE İLGİLİ DENEYSEL BİR ÇALIŞMA

AYNA ÖNÜ AYDINLATMASI İLE İLGİLİ DENEYSEL BİR ÇALIŞMA AYNA ÖNÜ AYDINLATMASI İLE İLGİLİ DENEYSEL BİR ÇALIŞMA Filiz AÇARİ, Leyla DOKUZER ÖZTÜRK Yıldız Teknik Üniversitesi, Mimarlık Fakültesi, Mimarlık Bölümü, Yapı Bilgisi Anabilim Dalı, Yapı Fiziği Bilim Alanı,

Detaylı

G Ü N E Ş K I R I C I L A R I V E R A F L A R I. Prof. Dr. Salih OFLUOĞLU

G Ü N E Ş K I R I C I L A R I V E R A F L A R I. Prof. Dr. Salih OFLUOĞLU G Ü N E Ş K I R I C I L A R I V E R A F L A R I Prof. Dr. Salih OFLUOĞLU P a s i f B i n a T a s a r ı m ı Pasif bina tasarımı, yerel iklim ve çevre koşullarından faydalanarak kullanıcıların konfor, sağlık

Detaylı

İlköğretim dersliklerinin görsel konfor açısından incelenmesi ve değerlendirilmesi

İlköğretim dersliklerinin görsel konfor açısından incelenmesi ve değerlendirilmesi itüdergisi/a mimarlık, planlama, tasarım Cilt:8, Sayı:1, 15-116 Mart 9 İlköğretim dersliklerinin görsel konfor açısından incelenmesi ve değerlendirilmesi Alpin KÖKNEL YENER *, Rana KUTLU GÜVENKAYA, Feride

Detaylı

RÜZGAR ENERJİSİ VE SİVAS ŞARTLARINDA RÜZGAR SANTRALİ TASARIMI

RÜZGAR ENERJİSİ VE SİVAS ŞARTLARINDA RÜZGAR SANTRALİ TASARIMI RÜZGAR ENERJİSİ VE SİVAS ŞARTLARINDA RÜZGAR SANTRALİ TASARIMI Cumhuriyet Üniversitesi Elektrik - Elektronik Mühendisliği Bölümü Sunan Yrd.Doç. Dr. Mustafa HOŞTUT Nisan-2007 1/53 RÜZGAR ENERJİSİ VE SİVAS

Detaylı

BİNALARIN ENERJİ ETKİN AYDINLATMA SİSTEMLERİ OLARAK TASARLANMASI

BİNALARIN ENERJİ ETKİN AYDINLATMA SİSTEMLERİ OLARAK TASARLANMASI BİNALARIN ENERJİ ETKİN AYDINLATMA SİSTEMLERİ OLARAK TASARLANMASI Alpin Köknel YENER Mimarlık Fakültesi İstanbul Teknik Üniversitesi, 34437,Tașkıșla Taksim,İstanbul alpin.yener@itu.edu.tr ABSTRACT Today,

Detaylı

GÜN IŞIĞI KULLANILARAK İÇ MEKANLARIN AYDINLATILMASI

GÜN IŞIĞI KULLANILARAK İÇ MEKANLARIN AYDINLATILMASI GÜN IŞIĞI KULLANILARAK İÇ MEKANLARIN AYDINLATILMASI HAZIRLAYAN ÖĞRENCİ: Emincan AYÇİÇEK (9/A) DANIŞMAN ÖĞRETMEN: A. Ruhşah ERDUYGUN 2005 İZMİR İÇİNDEKİLER Özet...2 Gün Işığı Kullanılarak İç Mekanların

Detaylı

AYDINLATMA TÜRLERİ 1

AYDINLATMA TÜRLERİ 1 1 AYDINLATMA TÜRLERİ Aydınlatma Türleri Işık Kökeni Bakımından Aydınlatma Türleri Doğal Aydınlatma Suni Aydınlatma Aydınlatılan Yere Göre Aydınlatma Türleri İç Aydınlatma Dış Aydınlatma Amacı Bakımından

Detaylı

KULLANICILARIN AYDINLIK DÜZEYĐ TERCĐHLERĐNĐN DEĞĐŞKENLĐĞĐ ÜZERĐNE BĐR ÇALIŞMA

KULLANICILARIN AYDINLIK DÜZEYĐ TERCĐHLERĐNĐN DEĞĐŞKENLĐĞĐ ÜZERĐNE BĐR ÇALIŞMA KULLANICILARIN AYDINLIK DÜZEYĐ TERCĐHLERĐNĐN DEĞĐŞKENLĐĞĐ ÜZERĐNE BĐR ÇALIŞMA Lale ERDEM 1, Dilek ENARUN 2 Elektrik Mühendisliği Bölümü Elektrik-Elektronik Fakültesi Đstanbul Teknik Üniversitesi, 34469,

Detaylı

HAMZA ALTINSOY & ÖMER DOĞRU İş Sağlığı ve Güvenliği Uzman Yardımcısı

HAMZA ALTINSOY & ÖMER DOĞRU İş Sağlığı ve Güvenliği Uzman Yardımcısı T.C. ÇALIŞMA VE SOSYAL GÜVENLİK BAKANLIĞI İŞ SAĞLIĞI VE GÜVENLİĞİ GENEL MÜDÜRLÜĞÜ İŞ SAĞLIĞI VE GÜVENLİĞİ ENSTİTÜSÜ HAMZA ALTINSOY & ÖMER DOĞRU İş Sağlığı ve Güvenliği Uzman Yardımcısı 1 STANDARTLAR &

Detaylı

T.C. MİLLİ EĞİTİM BAKANLIĞI TÜBİTAK- BİDEB YİBO ÖĞRETMENLERİ (FİZİK) PROJE DANIŞMANLIĞI EĞİTİMİ ÇALIŞTAYI ÇALIŞTAY 2009-2

T.C. MİLLİ EĞİTİM BAKANLIĞI TÜBİTAK- BİDEB YİBO ÖĞRETMENLERİ (FİZİK) PROJE DANIŞMANLIĞI EĞİTİMİ ÇALIŞTAYI ÇALIŞTAY 2009-2 T.C. MİLLİ EĞİTİM BAKANLIĞI TÜBİTAK- BİDEB YİBO ÖĞRETMENLERİ (FİZİK) PROJE DANIŞMANLIĞI EĞİTİMİ ÇALIŞTAYI ÇALIŞTAY 29-2 PROJE ADI: KUZEY CEPHELİ EVLERDE GÜNEŞ IŞIĞINDAN DOĞRUDAN FAYDALANMA GRUP ADI: FEN-ER

Detaylı

LED LER VE AYDINLATMA

LED LER VE AYDINLATMA WIN FAZ II PANEL TÜYAP - BÜYÜKÇEKMECE LED LER VE AYDINLATMA 19 Mart 2011 Cumartesi Prof. Dr. Sermin ONAYGİL İTÜ Enerji Enstitüsü Giriş Aydınlatma: tüketilen toplam elektrik enerjisi içindeki payı - ~%20

Detaylı

Direnç ALIŞTIRMALAR

Direnç ALIŞTIRMALAR 58 2.10. ALIŞTIRMALAR Soru 2.1 : Direnci 7 olan alüminyumdan yapılmış bir iletim hattının kesiti 0.2cm 2 dir. Buna göre, hattın uzunluğu kaç km.dir (KAl = 35 m/ mm 2 ). (Cevap : L = 52.5 km) Soru 2.2 :

Detaylı

TS 12514 E GÖRE HERMETİK CİHAZ YERLEŞİM KURALLARI

TS 12514 E GÖRE HERMETİK CİHAZ YERLEŞİM KURALLARI TS 12514 E GÖRE HERMETİK CİHAZ YERLEŞİM KURALLARI 1.2.4 - C Tipi Cihazların (Hermetik) Montajı 1.2.4.1 - Genel Şartlar C tipi cihazlar (hermetik) montaj odasının hacmi ve havalandırma biçiminde bağlı olmaksızın

Detaylı

Genel Aydınlatmada LED Teknolojileri

Genel Aydınlatmada LED Teknolojileri Genel Aydınlatmada LED Teknolojileri Prof. Dr. Aydınlatma Türk Milli Komitesi Başkanı İTÜ Enerji Enstitüsü, Enerji Planlaması ve Yönetimi A.B.D. Başkanı ISO AGİD Genişletilmiş Sektör Toplantısı LED Aydınlatmada

Detaylı

ULUDAĞ ÜNİVERSİTESİ MÜHENDİSLİK FAKÜLTESİ OTOMOTİV MÜHENDİSLİĞİ BÖLÜMÜ

ULUDAĞ ÜNİVERSİTESİ MÜHENDİSLİK FAKÜLTESİ OTOMOTİV MÜHENDİSLİĞİ BÖLÜMÜ ULUDAĞ ÜNİVERSİTESİ MÜHENDİSLİK FAKÜLTESİ OTOMOTİV MÜHENDİSLİĞİ BÖLÜMÜ OTO4003 OTOMOTİV MÜHENDİSLİĞİ LABORATUVARI DENEY FÖYÜ LAB. NO:.. DENEY ADI : SES İLETİM KAYBI DENEYİ 2017 BURSA 1) AMAÇ Bir malzemenin

Detaylı

TOPOĞRAFİK HARİTALAR VE KESİTLER

TOPOĞRAFİK HARİTALAR VE KESİTLER TOPOĞRAFİK HARİTALAR VE KESİTLER Prof.Dr. Murat UTKUCU Yrd.Doç.Dr. ŞefikRAMAZANOĞLU TOPOĞRAFİK HARİTALAR VE Haritalar KESİTLER Yeryüzü şekillerini belirli bir yöntem ve ölçek dahilinde plan konumunda gösteren

Detaylı

ÇATI KONSTRÜKSİYONLARINDA GAZBETON UYGULAMALARI Doç.Dr.Oğuz Cem Çelik İTÜ Mimarlık Fakültesi Yapı Statiği ve Betonarme Birimi

ÇATI KONSTRÜKSİYONLARINDA GAZBETON UYGULAMALARI Doç.Dr.Oğuz Cem Çelik İTÜ Mimarlık Fakültesi Yapı Statiği ve Betonarme Birimi ÇATI KONSTRÜKSİYONLARINDA GAZBETON UYGULAMALARI Doç.Dr.Oğuz Cem Çelik İTÜ Mimarlık Fakültesi Yapı Statiği ve Betonarme Birimi ÖZET Donatılı gazbeton çatı panellerinin çeşitli çatı taşıyıcı sistemlerinde

Detaylı

Aydınlatma Hesabı ve Aydınlatma Cetvelinin Oluşturulması Elektrik tesisat projelerinde her bir alan için ayrı ayrı odanın kullanım şekline, alanına,

Aydınlatma Hesabı ve Aydınlatma Cetvelinin Oluşturulması Elektrik tesisat projelerinde her bir alan için ayrı ayrı odanın kullanım şekline, alanına, 1 AYDINLATMA HESABI Aydınlatma Hesabı ve Aydınlatma Cetvelinin Oluşturulması Elektrik tesisat projelerinde her bir alan için ayrı ayrı odanın kullanım şekline, alanına, geometrisine ve gerekli aydınlık

Detaylı

Binalarda Enerji Performansı

Binalarda Enerji Performansı Binalarda Enerji Performansı Yönetmelik, Hesaplama Yöntemi, Referans Bina ve Enerji Sınıflandırması, Yazılım, Süreçler Aralık 2009 B.İ.B. Yapı İşleri Genel Müdürlüğü Binalarda Enerji Verimliliği Şube Müdürlüğü

Detaylı

Akreditasyon Sertifikası Eki (Sayfa 1/8) Akreditasyon Kapsamı

Akreditasyon Sertifikası Eki (Sayfa 1/8) Akreditasyon Kapsamı Akreditasyon Sertifikası Eki (Sayfa 1/8) Kalibrasyon Laboratuvarı Adresi : Nilüfer Ticaret Merkezi 2.kısım 635 sokak Otomasyon plaza No:7 Nilüfer 16120 BURSA / TÜRKİYE Tel : 0 224 441 55 77 Faks : 0 224

Detaylı

KONYA KARAPINAR 300 KİŞİLİK ÖĞRENCİ YURDU İnceleme Dosyası

KONYA KARAPINAR 300 KİŞİLİK ÖĞRENCİ YURDU İnceleme Dosyası 2012 KONYA KARAPINAR 300 KİŞİLİK ÖĞRENCİ YURDU İnceleme Dosyası Konya Karapınar da yapılması planlanan 300 Kişilik Öğrenci yurduna ait genel bilgi ve maliyet çalışması Halil ATLI ESEER İNŞAAT 03.02.2012

Detaylı

Performans Tabloları Yalınkat Camlar

Performans Tabloları Yalınkat Camlar Performans Tabloları Yalınkat Camlar Kaplamalı Yüzey Gün Işığı Soğurma Güneş Enerjisi Direkt Toplam Gölgeleme Isı (U Değeri) W/m 2 K Gümüş #1 38 33 27 30 43 50 0,57 5,7 #2 38 27 20 38 43 52 0,59 5,7 Yeşil

Detaylı

DENEY 3. Maksimum Güç Transferi

DENEY 3. Maksimum Güç Transferi ULUDAĞ ÜNİVERSİTESİ MÜHENDİSLİK FAKÜLTESİ ELEKTRİK-ELEKTRONİK MÜHENDİSLİĞİ BÖLÜMÜ EEM2104 Elektrik Devreleri Laboratuarı II 2014-2015 Bahar DENEY 3 Maksimum Güç Transferi Deneyi Yapanın Değerlendirme Adı

Detaylı

ew Cove MX Powercore korniş aydınlatması, genel ve abajurlu aydınlatma için maksimum çıkışlı lineer LED armatür

ew Cove MX Powercore korniş aydınlatması, genel ve abajurlu aydınlatma için maksimum çıkışlı lineer LED armatür ew Cove MX Powercore korniş aydınlatması, genel ve abajurlu aydınlatma için maksimum çıkışlı lineer LED armatür ew Cove MX Powercore ew Cove MX Powercore, üstün ışık çıkışı, geniş ışın açısı ve çeşitli

Detaylı

Aydınlatma, çevre ve nesnelerin en iyi şekilde görülebilmesi

Aydınlatma, çevre ve nesnelerin en iyi şekilde görülebilmesi *tahsin basaran:sablon 10.07.2009 15:35 Page 47 İzmir deki Bir Bina İçin İklimlendirme ve Aydınlatma Enerji Yüklerinin Azaltılmasına Yönelik Paremetrik Bir Çalışma Yrd. Doç. Dr. Tahsin BAŞARAN Burcu ÇİFTÇİ

Detaylı

Akreditasyon Sertifikası Eki (Sayfa 1/5) Akreditasyon Kapsamı

Akreditasyon Sertifikası Eki (Sayfa 1/5) Akreditasyon Kapsamı Akreditasyon Sertifikası Eki (Sayfa 1/5) Adresi : Gökçeyurt Mahallesi Kümeevleri No:1 Mamak 06261 ANKARA / TÜRKİYE Tel : 0 312 590 90 00 Faks : 0 312 590 91 48 E-Posta : sage@tubitak.gov.tr Website : www.sage.tubitak.gov.tr

Detaylı

Deneyin Adı: Isı Geri Kazanımlı, Sıcaklığı Oransal Olarak Kontrol Edilen Sıcak Hava Üretim Sistemi

Deneyin Adı: Isı Geri Kazanımlı, Sıcaklığı Oransal Olarak Kontrol Edilen Sıcak Hava Üretim Sistemi Deneyin Adı: Isı Geri Kazanımlı, Sıcaklığı Oransal Olarak Kontrol Edilen Sıcak Hava Üretim Sistemi Deneyin yapılacağı yer: Enerji Sistemleri Mühendisliği Bölümü Laboratuar Binası, 2. Kat Enerji Verimliliği

Detaylı

Murat BAYRAM Mak.Yük.Müh.- Şb.Müd.V. B.İ.B. Yapı İşleri Genel Müdürlüğü Binalarda Enerji Verimliliği Şube Müdürlüğü. bayram.bay@gmail.

Murat BAYRAM Mak.Yük.Müh.- Şb.Müd.V. B.İ.B. Yapı İşleri Genel Müdürlüğü Binalarda Enerji Verimliliği Şube Müdürlüğü. bayram.bay@gmail. Murat BAYRAM Mak.Yük.Müh.- Şb.Müd.V. B.İ.B. Yapı İşleri Genel Müdürlüğü Binalarda Enerji Verimliliği Şube Müdürlüğü 5 Aralık 2008 tarihinde yayınlanan Binalarda Enerji Performansı Yönetmeliği, yeni ve

Detaylı

BÖLGESEL KONTROLLÜ LED AYDINLATMA SİSTEMİ İLE KONVANSİYONEL FLÜORESAN AYDINLATMA SİSTEMİNİN KARŞILAŞTIRILMASI

BÖLGESEL KONTROLLÜ LED AYDINLATMA SİSTEMİ İLE KONVANSİYONEL FLÜORESAN AYDINLATMA SİSTEMİNİN KARŞILAŞTIRILMASI BÖLGESEL KONTROLLÜ LED AYDINLATMA SİSTEMİ İLE KONVANSİYONEL FLÜORESAN AYDINLATMA SİSTEMİNİN KARŞILAŞTIRILMASI Mehmet Ali ÖZÇELİK ozcelik@gantep.edu.tr Gaziantep Üniversitesi, Teknik Bilimler Meslek Yüksekokulu

Detaylı

BİLGİSAYAR DESTEKLİ PROJE II (AYDINLATMA VE KUVVET PROJESİ ÇİZİMİ)

BİLGİSAYAR DESTEKLİ PROJE II (AYDINLATMA VE KUVVET PROJESİ ÇİZİMİ) 1 BİLGİSAYAR DESTEKLİ PROJE II (AYDINLATMA VE KUVVET PROJESİ ÇİZİMİ) BİLGİSAYAR DESTEKLİ PROJE II YILSONU NOTU KATKI ORANLARI Dersin Adı Dönemi Dersin Kredisi AKTS Bilgisayar Destekli Proje II Bahar Dönemi

Detaylı

Light Warrior. Aydınlatma sistemleri için elektrik tasarruf cihazı

Light Warrior. Aydınlatma sistemleri için elektrik tasarruf cihazı Aydınlatma sistemleri için elektrik tasarruf cihazı %20 - %40 arasında enerji tasarrufu Flüoresan, metal-halide, sodium buharlı, compact flüoresan lambalar, akkor flamanlı spot ve armatürlerinde etkili

Detaylı

XII. ULUSAL TESİSAT MÜHENDİSLİĞİ KONGRESİ ERGİN BAYRAK, NACİ ŞAHİN Nisan 2015, İZMİR

XII. ULUSAL TESİSAT MÜHENDİSLİĞİ KONGRESİ ERGİN BAYRAK, NACİ ŞAHİN Nisan 2015, İZMİR KANATLI BORULU EVAPORATÖRLERDE DEVRE TASARIMININ KAPASİTEYE ETKİSİNİN N DENEYSEL OLARAK İNCELENMESİ ERGİN BAYRAK, NACİ ŞAHİN Isı Değiştiricilerine Genel Bir Bakış Kanatlı Borulu Isı Değiştiricileri Problemler

Detaylı

GÜN IŞIĞI İLE AYDINLATMA ALANINDA GELİŞTİRİLEN YENİ TEKNOLOJİLER HAKKINDA BİR ARAŞTIRMA. YÜKSEK LİSANS TEZİ Mimar Burak EREL. Anabilim Dalı : MİMARLIK

GÜN IŞIĞI İLE AYDINLATMA ALANINDA GELİŞTİRİLEN YENİ TEKNOLOJİLER HAKKINDA BİR ARAŞTIRMA. YÜKSEK LİSANS TEZİ Mimar Burak EREL. Anabilim Dalı : MİMARLIK İSTANBUL TEKNİK ÜNİVERSİTESİ FEN BİLİMLERİ ENSTİTÜSÜ GÜN IŞIĞI İLE AYDINLATMA ALANINDA GELİŞTİRİLEN YENİ TEKNOLOJİLER HAKKINDA BİR ARAŞTIRMA YÜKSEK LİSANS TEZİ Mimar Burak EREL Anabilim Dalı : MİMARLIK

Detaylı

Test. Yerküre nin Şekli ve Hareketleri BÖLÜM 4

Test. Yerküre nin Şekli ve Hareketleri BÖLÜM 4 Yerküre nin Şekli ve Hareketleri 1. Dünya ile ilgili aşağıda verilen bilgilerden yanlış olan hangisidir? A) Dünya, ekseni etrafındaki bir turluk dönüş hareketini 24 saatte tamamlar. B) Dünya ekseni etrafındaki

Detaylı

Atıksu Arıtma Tesislerinde Hava Dağıtımının Optimize Edilmesi ve Enerji Tasarrufu

Atıksu Arıtma Tesislerinde Hava Dağıtımının Optimize Edilmesi ve Enerji Tasarrufu Optimization of Air Distribution in Waste Water Treatment Plants to Save Energy Atıksu Arıtma Tesislerinde Hava Dağıtımının Optimize Edilmesi ve Enerji Tasarrufu Jan Talkenberger, Binder Group, Ulm, Germany

Detaylı

Mavi C:70 M:35 Y:0 K:0 Yeşil C:70 M:0 Y:100 K:0 Turuncu C:0 M:52 Y:100 K:0 Siyah C:50 M:50 Y:50 K:100 Kırmızı C:0 M:100 Y:100 K:20

Mavi C:70 M:35 Y:0 K:0 Yeşil C:70 M:0 Y:100 K:0 Turuncu C:0 M:52 Y:100 K:0 Siyah C:50 M:50 Y:50 K:100 Kırmızı C:0 M:100 Y:100 K:20 ASKAJANS ın logosu yatay bir formattadır. Logodaki ASK yazının sol tarafında üç (3) renkten oluşan soldan sağa kırk beş (45) derecelik açılara sahip yatay figürler bulunmaktadır. Logonun boyutları basılı

Detaylı

DistanceMaster One. Laser 650 nm SPEED SHUTTER

DistanceMaster One. Laser 650 nm SPEED SHUTTER DistanceMaster One 52 Laser 650 nm SPEED SHUTTER Laser 02 2 x Typ AAA / LR03 1,5V / Alkaline DistanceMaster One x x y = m 2 y z x y x y z = m 3 03 ! Kullanım kılavuzunu ve ekte bulunan Garanti Bilgileri

Detaylı

BÜTÜNLEŞİK TASARIM BİNA ENERJİ VERİMLİLİĞİ YEŞİL BİNALAR

BÜTÜNLEŞİK TASARIM BİNA ENERJİ VERİMLİLİĞİ YEŞİL BİNALAR BÜTÜNLEŞİK TASARIM BİNA ENERJİ VERİMLİLİĞİ YEŞİL BİNALAR ENERJİ VERİMLİLİĞİNİ ARTIRMA POTANSİYELİMİZ! Binalarda enerjinin verimli kullanılmasını sağlayarak, ülke çapında enerji tüketimimizi yaşam konforumuzdan

Detaylı

Şehir ve Bölge Planlamada Tasarım Değişkeni Boğuculuk Fonksiyonu için Değişkeleme Önerisi. R. Haluk KUL TC Beykent Üniversitesi, hkul@beykent.edu.

Şehir ve Bölge Planlamada Tasarım Değişkeni Boğuculuk Fonksiyonu için Değişkeleme Önerisi. R. Haluk KUL TC Beykent Üniversitesi, hkul@beykent.edu. Şehir ve Bölge Planlamada Tasarım Değişkeni Boğuculuk Fonksiyonu için Değişkeleme Önerisi R. Haluk KUL TC Beykent Üniversitesi hkul@beykent.edu.tr ÖZET Uydu Kentlerin tasarımında kullanılmak üzere önerilen

Detaylı

Dik İzdüşüm Teorisi. Prof. Dr. Muammer Nalbant. Muammer Nalbant

Dik İzdüşüm Teorisi. Prof. Dr. Muammer Nalbant. Muammer Nalbant Dik İzdüşüm Teorisi Prof. Dr. Muammer Nalbant Muammer Nalbant 2017 1 Dik İzdüşüm Terminolojisi Bakış Noktası- 3 boyutlu uzayda bakılan nesneden sonsuz uzaktaki herhangi bir yer. Bakış Hattı- gözlemcinin

Detaylı

TEKNOLOJİK ARAŞTIRMALAR

TEKNOLOJİK ARAŞTIRMALAR www.teknolojikarastirmalar.org ISSN:1304-4141 Makine Teknolojileri Elektronik Dergisi 2006 (3) 33-37 TEKNOLOJİK ARAŞTIRMALAR Makale Kemal ATİK, Hakkı ÇAKIR Zonguldak Karaelmas Üniversitesi Karabük Teknik

Detaylı

Giray Kansu YILDIRIM 3003110055 KNX

Giray Kansu YILDIRIM 3003110055 KNX Giray Kansu YILDIRIM 3003110055 KNX KNX eski kontrol sistemlerinde ayrı ayrı kontrol edilen fonksiyonları tek bir çatı altına toplar. KNX Nedir? Enerji Kullanımında Sektörel Dağılım Enerji Verimliliği

Detaylı

İÇİNDEKİLER SUNUŞ 2012 YILI KURUMSAL MALİ DURUM VE BEKLENTİLER RAPORU 1 I- OCAK HAZİRAN 2012 DÖNEMİ BÜTÇE UYGULAMA SONUÇLARI 6 1) BÜTÇE GİDERLERİ 6

İÇİNDEKİLER SUNUŞ 2012 YILI KURUMSAL MALİ DURUM VE BEKLENTİLER RAPORU 1 I- OCAK HAZİRAN 2012 DÖNEMİ BÜTÇE UYGULAMA SONUÇLARI 6 1) BÜTÇE GİDERLERİ 6 İÇİNDEKİLER SUNUŞ I 2012 YILI KURUMSAL MALİ DURUM VE BEKLENTİLER RAPORU 1 I- OCAK HAZİRAN 2012 DÖNEMİ BÜTÇE UYGULAMA SONUÇLARI 6 1) BÜTÇE GİDERLERİ 6 A. Personel Giderleri 6 B. Sosyal Güvenlik Kurumlarına

Detaylı

BİNALARDA ENERJİ KİMLİK BELGESİ (EKB)NEDİR?

BİNALARDA ENERJİ KİMLİK BELGESİ (EKB)NEDİR? BİNALARDA ENERJİ KİMLİK BELGESİ (EKB)NEDİR? 5627 Sayılı Enerji Verimliliği Kanunu ve buna bağlı olarak çıkartılan Binalarda Enerji Performansı Yönetmeliği ne göre, binalarda enerjinin ve enerji kaynaklarının

Detaylı

Aydınlatma ve İç Tesisat Laboratuvarı Demo II KNX

Aydınlatma ve İç Tesisat Laboratuvarı Demo II KNX Aydınlatma ve İç Tesisat Laboratuvarı Demo II KNX KNX eski kontrol sistemlerinde ayrı ayrı kontrol edilen fonksiyonları tek bir çatı altına toplar. KNX Nedir? Enerji Kullanımında Sektörel Dağılım Enerji

Detaylı

Sinerji Mühendislik Müşavirlik İnşaat Sanayi ve Tic. Ltd. Şti.

Sinerji Mühendislik Müşavirlik İnşaat Sanayi ve Tic. Ltd. Şti. NEDEN NATÜREL IŞIK? Mekânlarınızın aydınlatma ampullerini kapalı tutarak elektrik tasarrufu mu yapıyorsunuz? Siyah sandığınız giysinizin aslında yeşil olduğunu fark etmeniz durumu sıklıkla başınıza geliyor

Detaylı

İZMİR DEKİ BİR BİNA İÇİN İKLİMLENDİRME VE AYDINLATMA ENERJİ YÜKLERİNİN AZALTILMASINA YÖNELİK PAREMETRİK BİR ÇALIŞMA

İZMİR DEKİ BİR BİNA İÇİN İKLİMLENDİRME VE AYDINLATMA ENERJİ YÜKLERİNİN AZALTILMASINA YÖNELİK PAREMETRİK BİR ÇALIŞMA 57 İZMİR DEKİ BİR BİNA İÇİN İKLİMLENDİRME VE AYDINLATMA ENERJİ YÜKLERİNİN AZALTILMASINA YÖNELİK PAREMETRİK BİR ÇALIŞMA Tahsin BAŞARAN Burcu ÇİFTÇİ ÖZET Bu çalışmada, ofis binalarındaki aydınlatma ve iklimlendirme

Detaylı

İlgili idareler, sorumluluğun takip, tespit ve gereğinin yerine getirilmesi hususunda görevli ve yetkilidir.

İlgili idareler, sorumluluğun takip, tespit ve gereğinin yerine getirilmesi hususunda görevli ve yetkilidir. BİNALARDA ENERJİ KİMLİK BELGESİ (EKB)NEDİR? 5627 Sayılı Enerji Verimliliği Kanunu ve buna bağlı olarak çıkartılan Binalarda Enerji Performansı Yönetmeliği ne göre, binalarda enerjinin ve enerji kaynaklarının

Detaylı

BİNALARA İLİŞKİN AYDINLATMA ENERJİ TÜKETİMİ ÖNGÖRÜLERİNDE ETKİN BİR DEĞER: KULLANICI KONTROLÜ

BİNALARA İLİŞKİN AYDINLATMA ENERJİ TÜKETİMİ ÖNGÖRÜLERİNDE ETKİN BİR DEĞER: KULLANICI KONTROLÜ 1.Ulusal Yapı Fiziği ve Çevre Kontrolü Kongresi 13-14 Mart 2014 İTÜ Mimarlık Fakültesi, İstanbul BİNALARA İLİŞKİN AYDINLATMA ENERJİ TÜKETİMİ ÖNGÖRÜLERİNDE ETKİN BİR DEĞER: KULLANICI KONTROLÜ Arş.Gör. Arzu

Detaylı

Uygulama kağıtları ve Kısa Sınav kağıtlarına; Ad, Soyad, Numara ve Grup No (Ör: B2-5) mutlaka yazılacak.

Uygulama kağıtları ve Kısa Sınav kağıtlarına; Ad, Soyad, Numara ve Grup No (Ör: B2-5) mutlaka yazılacak. Uygulama kağıtları ve Kısa Sınav kağıtlarına; Ad, Soyad, Numara ve Grup No (Ör: B2-5) mutlaka yazılacak. Grup Adı Ön Hazırlıkta bulunan sonuçlardan uygulama kağıdına yazılması gereken değerler deneye gelmeden

Detaylı

ENERJİ VERİMLİLİĞİNDE CAM

ENERJİ VERİMLİLİĞİNDE CAM ENERJİ VERİMLİLİĞİNDE CAM Türkiye İMSAD Sektörel Gelişim Toplantıları-Adana 3 Eylül 2015 Şişecam Düzcam Cam Ev Eşyası Cam Ambalaj Kimyasallar Şişecam Düzcam Düzcam üretiminde 50 yıllık tecrübe 1981 den

Detaylı