LABORATUVAR KOŞULLARINDA FARKLI TOPRAK BÜNYESİ VE TUZLULUĞUNA GÖRE 10HS TOPRAK NEM SENSÖRÜNÜN KALİBRASYON EĞRİLERİNİN BELİRLENMESİ

Benzer belgeler
Toprak Nemi Ölçme Metodları

SULAMA UYGULAMALARI İÇİN TDR ÖLÇÜMLERİNDE KALİBRASYONUN ÖNEMİ

ÖZET OTOMATİK KÖKLENDİRME SİSTEMİNDE ORTAM NEMİNİN SENSÖRLERLE HASSAS KONTROLÜ. Murat ÇAĞLAR

TOPRAK SUYU. Toprak Bilgisi Dersi. Prof. Dr. Günay Erpul

YARASA VE ÇİFTLİK GÜBRESİNİN BAZI TOPRAK ÖZELLİKLERİ ve BUĞDAY BİTKİSİNİN VERİM PARAMETRELERİ ÜZERİNE ETKİSİ

SULAMA-TEMEL KONULAR

Tarımsal Mekanizasyon 18. Ulusal Kongresi Tekirdağ 290

SIW TUZLULUK VE SODİKLİK ANALİZ ÜNİTESİ İLE TOPRAK VE SULAMA SUYU TUZLULUĞUNUN BELİRLENMESİ

Prof. Dr. Sait GEZGİN, Uzman Nesim DURSUN. Selçuk Üniversitesi Ziraat Fakültesi Toprak Bilimi ve Bitki Besleme Böl., Konya.

ISLAKLIK ÖLÇÜMLERİ. a. Metalin paslanması b. Tahtanın çürümesi c. Ekmeğin küflenmesi. Şekil 1. Malzemeler üzerindeki bozulmalar

Ölçme Kontrol ve Otomasyon Sistemleri 10

Murat Nehri (Elazığ) nin Bazı Fizikokimyasal Parametreler Açısından Su Kalitesinin Belirlenmesi

PİEZOELEKTRİK YAMALARIN AKILLI BİR KİRİŞİN TİTREŞİM ÖZELLİKLERİNİN BULUNMASINDA ALGILAYICI OLARAK KULLANILMASI ABSTRACT

KONİ İNDEKSİNİN BELİRLENMESİNE İLİŞKİN ÇEŞİTLİ YAKLAŞIM EŞİTLİKLERİNİN KARŞILAŞTIRILMASI

TOPRAK TOPRAK TEKSTÜRÜ (BÜNYESİ)

TARIMSAL YAPILAR VE SULAMA

BOĞAZİÇİ UNIVERSITY KANDİLLİ OBSERVATORY and EARTHQUAKE RESEARCH INSTITUTE GEOMAGNETISM LABORATORY

Sera Koşullarında A-Sınıfı Buharlaşma Kabı ve Küçük Buharlaşma Kaplarından Buharlaşan Su Miktarı Arasındaki İlişkiler

SÜLEYMAN DEMİREL ÜNİVERSİTESİ MÜHENDİSLİK FAKÜLTESİ KİMYA MÜHENDİSLİĞİ BÖLÜMÜ KMM 302 KİMYA MÜHENDİSLİĞİ LABORATUVARI-I ÖĞÜTME ELEME DENEYİ

TARIMSAL DRENAJ HAVZALARINDA SU BÜTÇESİ HESABI: SEYHAN ALT HAVZASI ÖRNEĞİ

Havza Amenajmanı Laboratuvarı

Çeltiğin Hızlı Kurutulması Sonucunda Maksimum Randıman Alabilmek Amacıyla Hasat Nemi - Maksimum Randıman Arasında İlişkinin Belirlenmesi

Büyüklüklerine Göre Zemin Malzemeleri

ELDAŞ Elektrik Elektronik Sanayi ve Tic.A.Ş.

Bazı Ceviz (Juglans regia L.) Çeşitlerinin Çimlenme ve Çöğür (Anaçlık) Gelişme Performanslarının Belirlenmesi

ELMALAR ARASINDA ÇARPIŞMA ENERJİSİNE BAĞLI OLARAK ZEDELENMENİN SAPTANMASI C. AYDIN K. ÇARMAN

1.GİRİŞ. Şevki İSKENDEROĞLU 1, Bahadır İbrahim KÜTÜK 2, Şerife Pınar GÜVEL 3, Aynur FAYRAP 4,Mehmet İrfan ASLANKURT 5

Yüzüncü Yıl Üniversitesi Fen Bilimleri Enstitüsü Dergisi/ Journal of The Institute of Natural & Applied Sciences 17 (1):6-12, 2012

KURAK BIR BÖLGEDE BĠR KISIM TOPRAK ÖZELLIKLERININ MEKANSAL DEĞIġKENLIĞI

ZEMİN MEKANİĞİ DENEYLERİ

TOPRAK ANABİLİM DALI

TOC Analiz Cihazı Seçme Kriterleri

KİŞİSEL BİLGİLER EĞİTİM BİLGİLERİ

TOPRAK NEMİ ÖLÇÜMLERİ

Farklı malzemelerin dielektrik sabiti LEP _00

PARMAKLI VE TAMBURLU ÇAYIR BİÇME MAKİNALARINDA ARIZALANMA VE TAMİRE BAĞLI RİSK KATSAYISININ SİMÜLASYONLA BELİRLENMESİ

Flue Cured Tütün Çeşidinde Farklı Potasyum Formlarının Kaliteye Etkisi

Güneş enerjisi kullanılarak sulama sistemleri için yeni bilgi tabanlı model

TÜBİTAK-BİDEB Lise Öğretmenleri (Fizik, Kimya, Biyoloji ve Matematik) Proje Danışmanlığı Eğitimi Çalıştayı LİSE-2 (ÇALIŞTAY 2012) SUYUN DANSI

Yüz Tanımaya Dayalı Uygulamalar. (Özet)

METEOROLOJİ. VI. Hafta: Nem

ISSN: Yıl /Year: 2017 Cilt(Sayı)/Vol.(Issue): 1(Özel) Sayfa/Page: Araştırma Makalesi Research Article. Özet.

6. Seçilmiş 24 erkek tipte ağacın büyüme biçimi, ağacın büyüme gücü (cm), çiçeklenmenin çakışma süresi, bir salkımdaki çiçek tozu üretim miktarı,

PE = 0.7(AxBxCxX)+VE+KE (Eşitlik 8.1.) = 0.7TE+VE+KE (Eşitlik 8.2.)

SERAMİK/METAL OKSİT SENSÖRLÜ ÇİY-NOKTASI ÖLÇER KALİBRASYON SİSTEMİ

İSTANBUL BOĞAZI SU SEVİYESİ DEĞİŞİMLERİNİN MODELLENMESİ. Berna AYAT. İstanbul, Türkiye

SULAMA-TEMEL KONULAR

ÇİNKO KATKILI ANTİBAKTERİYEL ÖZELLİKTE HİDROKSİAPATİT ÜRETİMİ VE KARAKTERİZASYONU

HİDROLOJİ. Buharlaşma. Yr. Doç. Dr. Mehmet B. Ercan. İnönü Üniversitesi İnşaat Mühendisliği Bölümü

LCR METRE KALİBRASYONU

Farklı materyallerin elektrik geçirmezlik sabiti

Canıtez Çeşidi Nohutta Aynı Yükleme Hızında Ezilme Direnci Değişiminin Neme Bağlı Olarak Belirlenmesi

The Possibilities of the Direct Seeding of Watermelon Seed By Pneumatic Precision Planter

2006 NAMIK KEMAL ÜNİVERSİTESİ ZİRAAT FAKÜLTESİ JAİN - TOPDRİP PC SERİSİ. <(>16, 0.45 ve 0.63 mm Et Kalınlığı, 1.0 ve 1.

BÖLÜM-1 HİDROLOJİNİN TANIMI VE ÖNEMİ

SOLAREX İSTANBUL Güneş Enerjisi & Teknolojileri Fuarı

GAZBETONUN SU KARŞISINDAKİ DAVRANIŞI

10. HAFTA PARTİKÜL BÜYÜKLÜĞÜ TAYİN YÖNTEMLERİ

Açık Alandaki Saksılı Bitkilerin Kapillar Yöntem İle Sulanmasında İletim Materyali Genişlik ve Sayılarının Su Tüketimi Üzerine Etkileri

Sıkıştırma enerjisi arttıkça optimum su muhtevası azalmakta, kuru birim hacim ağırlık artmaktadır. Optimum su muhtevasına karşılık gelen birim hacim

NAMIK KEMAL ÜNİVERSİTESİ ZİRAAT FAKÜLTESİ BİYOSİSTEM MÜHENDİSLİĞİ BÖLÜMÜ

EAG 04. KCl ÇÖZELTİSİNİN METASTABİL BÖLGE GENİŞLİĞİNİN KNO 3 KATKISI VARLIĞINDA ULTRASONİK SENSÖRLE ÖLÇÜLEBİLİRLİLİĞİNİN İNCELENMESİ

OTOMATİK KÖKLENDİRME SİSTEMİNDE ORTAM NEMİNİN SENSÖRLERLE HASSAS KONTROLÜ

ZİRAAT FAKÜLTESİ BİYOSİSTEM MÜHENDİSLİĞİ BÖLÜMÜ

BAŞKENT ÜNİVERSİTESİ FEN BİLİMLERİ ENSTİTÜSÜ BENZER SÜREÇLERDE ÜRETİLEN ÜRÜNLER İÇİN YAPAY ZEKA İLE ZAMAN TAHMİNİ SONER ŞÜKRÜ ALTIN

TOLERANS DIŞINDA KALAN SES DÜZEYİ ÖLÇER TEPKİLERİNİN ÖLÇÜM SONUÇLARINA ETKİLERİ

GAZİANTEP KİLLERİNİN DİSPERSİBİLİTE ÖZELLİĞİNİN BELİRLENMESİ

BOŞLUK ORANINA GÖRE ZEMİN PRİZMASI ÇİZİLMESİ VE İLGİLİ FORMÜLLERİN ELDE EDİLMESİ

KÖMÜRCÜOĞLU MERMER FİRMASI TRAVERTEN DOĞALTAŞINA AİT DONA DAYANIM ANALİZ RAPORU

508 HİDROLOJİ ÖDEV #1

DUVARMATĠK 1150 MODÜLER DUVAR PANELĠNĠN ISI ĠLETĠM KATSAYISININ VE SES ĠLETĠM KAYBININ TAYĠNĠ

UME-EM AKIM TRANSFORMATÖRÜ KARŞILAŞTIRMASI RAPORU

Su Yastıkları ve Karık Sulama Yöntemlerinin Tarımsal Mekanizasyon Açısından Karşılaştırılması

1. Giriş. 2. Toprak kompozisyonu. Bölüm 1 - Topraklar ve Toprak Verimliliği. Modül 2 Toprak ve Besin Döngüsü

BİYOLOJİK YÖNTEMLE ARITILAN KENTSEL ATIK SULARIN YENİDEN KULLANIMI İÇİN NANOFİLTRASYON (NF) YÖNTEMİNİN UYGULANMASI

^\VWN ZİRAAT FAKÜLTESİ

SIVI YOĞUNLUKLARININ BİRİNCİL SEVİYEDE BELİRLENMESİNİ SAĞLAYAN ÖLÇÜM DÜZENEĞİ

ISSN: Yıl /Year: 2017 Cilt(Sayı)/Vol.(Issue): 1(Özel) Sayfa/Page: Araştırma Makalesi Research Article

1. DOĞAL ÜZERİNDEKİ ETKİLER. PDF created with pdffactory trial version

ÇEVRESEL TEST HİZMETLERİ 2.ENVIRONMENTAL TESTS

DRENAJ KANALLARINDA MEVSİMSEL KİRLENMENİN BELİRLENMESİ, AŞAĞI SEYHAN ÖRNEĞİ *

METİLEN MAVİSİ DEĞERİ YÜKSEK AGREGALAR VE FARKLI ÖZELLİKTEKİ KİMYASAL KATKILARLA YAPILAN BETON ÇALIŞMALARI

Tohum Yatağı Hazırlamada Uygulanan Farklı Toprak İşleme Yöntemleri Üzerine Bir Araştırma

QUANTILE REGRESYON * Quantile Regression

Araziye Çıkmadan Önce Mutlaka Bizi Arayınız!

Teşekkür. BOĞAZİÇİ UNIVERSITY KANDİLLİ OBSERVATORY and EARTHQUAKE RESEARCH INSTITUTE GEOMAGNETISM LABORATORY

İYC MADENCİLİK SAN. VE TİC. LTD. ŞTİ. NE AİT MUĞLA - FETHİYE YÖRESİ BEJ TÜRÜ KİREÇTAŞININ FİZİKO-MEKANİK ANALİZ RAPORU

PARÇA MEKANİĞİ UYGULAMA 1 ŞEKİL FAKTÖRÜ TAYİNİ

ARAÇ HAVZASINDA FİZİKSEL BÜTÜNLEŞİK HİDROLOJİK MODEL ÇALIŞMASI. Koray K. Yılmaz Yağmur Derin

HİDROLOJİ Doç.Dr.Emrah DOĞAN

NAMIK KEMAL ÜNİVERSİTESİ ZİRAAT FAKÜLTESİ BİYOSİSTEM MÜHENDİSLİĞİ BÖLÜMÜ

Muzun Farklı Kurutma Şartlarındaki Kuruma Karakteristiklerinin Belirlenmesi

TEMEL (FİZİKSEL) ÖZELLİKLER

Selçuk Üniversitesi Ziraat Fakültesi Dergisi 21 (43): (2007) 86-97

7. Bölüm: MİNERAL TOPRAKLARIN FİZİKSEL ÖZELLİKLERİ

Penetrasyon Direncine Etki Eden Toprak Özelliklerine Ait Etki Katsayılarının Çoklu Regresyon Analizi ile Belirlenmesi

T.C. SÜLEYMAN DEMİREL ÜNİVERSİTESİ FEN BİLİMLERİ ENSTİTÜSÜ ISPARTA İLİ KİRAZ İHRACATININ ANALİZİ

FİZ304 İSTATİSTİK FİZİK. Mikrokopik Teori ve Makroskopik Ölçümler I. Prof.Dr. Orhan ÇAKIR Ankara Üniversitesi, Fizik Bölümü 2017

İNŞAAT MALZEME BİLGİSİ

Selçuk Üniversitesi Ziraat Fakultesi Bahçe Bitkileri Bolumu Selçuklu/KONYA (Sorumlu Yazar)

Transkript:

LABORATUVAR KOŞULLARINDA FARKLI TOPRAK BÜNYESİ VE TUZLULUĞUNA GÖRE 10HS TOPRAK NEM SENSÖRÜNÜN KALİBRASYON EĞRİLERİNİN BELİRLENMESİ Gökçe BÜYÜKÇEKİÇ 1 Dursun BÜYÜKTAŞ 1 Cihan KARACA 1 Ruhi BAŞTUĞ 1 Köksal AYDINŞAKİR 2 Kenan BÜYÜKTAŞ 1 1 Akdeniz Üniversitesi, Ziraat Fakültesi, Tarımsal Yapılar ve Sulama Bölümü, Antalya, Türkiye 2 Batı Akdeniz Tarımsal Araştırma Enstitüsü Müdürlüğü, Antalya, Türkiye Özet Toprak su içeriğinin doğru bir şekilde ölçülmesi sulama ile ilgili çalışmalarda su dengesinin kurulmasında kritik öneme sahiptir. Toprak su içeriğinin belirlenmesinde gravimetrik yöntem en doğru sonucu vermesine karşın zaman alıcı ve iş yükünün fazla olması nedeniyle toprak dielektrik sabitine bağlı farklı nemölçerler geliştirilmiştir. Ancak geliştirilen bu cihazlar hem toprak bünyesinden hem de toprak tuzluluğundan önemli derecede etkilenmektedirler. Bu nedenle söz konusu cihazların kullanımından önce farklı toprak bünyesi ve tuzluluğuna bağlı olarak kalibrasyon eğrilerinin oluşturulması gerekmektedir. Bu çalışmanın amacı, 10HS toprak nem sensörünün kumlu ve tınlı olmak üzere iki farklı toprak bünyesi ve 0.7 (şebeke suyu, kontrol), 1.5, 3.0, 6.0 ve 12 ds/m olmak üzere beş farklı elektriksel iletkenliğe sahip su kullanılarak nin laboratuar koşullarında belirlenmesidir. Bu amaçla, 2 mm lik elekten elenmiş kumlu ve tınlı toprak örnekleri doğal birim hacim ağırlığını sağlayacak şekilde 1.5 litrelik saksılara yerleştirilmiş ve 30 gün süre ile farklı elektriksel iletkenliğe sahip sularla alttan doyurulmuştur. Toprağın doygun olduğu su içeriğinden solma noktası düzeyine kadar saksılar, günlük olarak tartılmış ve aynı zamanda nemölçer ile toprak su içeriği, milivolt cinsinden ölçülmüştür. Daha sonra elde edilen verilerden yararlanılarak üçüncü dereceden polinom biçiminde regresyon denklemleri belirlenmiştir. Araştırma sonucunda, toprak nem sensörünü üreten firma tarafından önerilen kalibrasyon katsayıları ile bu çalışmada elde edilen katsayıların önemli düzeyde farklı olduğu, kullanılan suyun elektriksel iletkenliğinin ni etkilediği belirlenmiştir. Toprak dielektrik sabitine bağlı olarak geliştirilen toprak nemölçerlerinin toprak su içeriğini doğru bir şekilde ölçebilmesi için yerel olarak kalibre edilmesi önerilmiştir. Anahtar Kelimeler: Tuzluluk, Nemölçer, Bünye, Kalibrasyon, 10HS DETERMINATION OF CALIBRATION CURVES OF 10HS SOIL MOISTURE SENSORS DEPENDING ON DIFFERENT SOIL TEXTURE AND SALINITY LEVELS UNDER LABORATORY CONDITIONS Abstract Accurate measurement of soil water content is critical to establishing water balance in irrigation related studies. Although the gravimetric method yielded the most accurate results in determining the soil water content, different sensors depending on the soil dielectric constant were developed due to the time consuming and high workload. However, these devices developed are significantly affected both from the soil texture and from soil salinity. For this reason, it is necessary to establish calibration curves depending on the different soil texture and salinity before using the related devices. The purpose of this study is to determine the calibration curves of 10HS soil moisture sensor under laboratory conditions using water with five different electrical conductivities 0.7 (tap water, control), 1.5, 3.0, 6.0 and 12 ds / m and two different soil types, sand and loam. For this purpose, samples of sandy and loamy soil sieved from a 2 mm sieve were placed in a 1.5 liter pot to provide natural bulk density and were saturated with water having different electrical conductivity for 30 days. The pots were weighed daily from saturated point until they reached the wilting point, and at the same time the moisture content of the soil and water was measured in millivolts. Then, regression equations in polynomial form are determined by using the obtained data. As a result of 1067

the research, it has been determined that the calibration coefficients proposed by the company that produces the soil moisture sensor are significantly different from the coefficients obtained in this study and that the electrical conductivity of the water used affects the calibration curves. It has been proposed to calibrate locally so that the soil moisture meters developed due to the soil dielectric constant can accurately measure the soil water content. Key Words: Salinity, Moisture Meter, Texture, Calibration, 10HS 1. GİRİŞ Toprak parçacıkları arasındaki boşluklarda tutulan su toprak nemi veya toprak su içeriği olarak adlandırılmaktadır. Küresel açıdan mevcut tatlı suyun küçük bir kısmını (% 0.15) oluşturan toprak nemi hidrolojik, biyolojik ve biyojeokimyasal süreçler için oldukça önemlidir. Doğru toprak suyu içeriği ölçümleri, enerji ve su dengesinin tahmininde olduğu kadar bitki kök bölgesindeki ve yeraltı sularındaki kimyasal ve biyolojik işlemleri anlamak için de kritik önem taşır. Ayrıca, tarımsal sulamanın sürdürülebilir bir şekilde yönetimi, toprak su içeriğinin doğru belirlenmesine bağlıdır (Usul, 2009). Toprak su içeriği doğrudan gravimetrik yöntemle veya dolaylı olarak piyasada bulunan kapasitans, TDR ve nötron saçılımı gibi toprak suyu içeriği izleme aletleri ile ölçülebilir. Gravimetrik yöntem en doğru sonucu veren yöntem olmakla birlikte yoğun emek isteyen, zaman alıcı ve toprağı bozan bir yöntemdir. Bu nedenle toprak su içeriğinin kapasitans, TDR ve nötron saçılımı gibi sensörlerden biri ile ölçülmesi gittikçe yaygınlaşmaktadır. Kapasitans yönteminde toprak su içeriğinin belirlenmesinde kullanılan temel yaklaşım toprağın dielektrik sabiti (2-5 arasında) ile suyun dielektrik sabitinin (81) farklı olmasıdır. Ancak bu sensörler ile ölçülen toprak su içeriği toprak bünyesi ve tuzluluk düzeyine bağlı olarak değiştiğinden söz konusu aletlerin bu parametrelere göre kalibrasyonlarının yapılması gerekmektedir (Dobriyal ve ark., 2012). Bu çalışmada Decagon firması tarafından üretilen 10HS (Dacagon, WA, USA) toprak nem sensörünün farklı toprak bünyesi ve tuzluluk düzeyine göre laboratuar koşullarında nin belirlenmesi amaçlanmıştır. Suyun dielektrik sabiti, hava veya toprak minerallerininkinden daha yüksek olduğu için, toprağın dielektrik sabiti hacimsel su içeriğinin duyarlı bir ölçüsüdür. 10HS toprak nem sensörü toprağın hacimsel su içeriğini (VWC) belirlemek için toprağın dielektrik sabitini ölçmektedir. Sensörün düşük güç gereksinimi ve çok yüksek çözünürlüğü avantajlarını oluşturmaktadır. Güç gereksinimi düşük olduğundan en az pil kullanımı ile uzun bir süre istenilen (örneğin saatlik) ölçümlerin yapılmasına olanak sağlar. 2005 yılında Decagon tarafından geliştirilen ilk sensör EC-5 in devamı olarak tasarlanan 10HS sensörü yaygın kullanılan toprak nem sensörlerinden biridir. 10HS sensörü de EC-5 ile aynı 70MHz frekansını kullanmakta ancak daha büyük bir toprak hacminde (1100 cm 3 ) ölçüm almaktadır. 10HS sensörü, toprakta bir pozitif ve toprak elektrotun (kapasitör) hızla şarj edilmesi ve boşaltılmasıyla, şarj süresi (t), toprağın kapasitansı (C) ile ilişkili olan bir elektromanyetik alan oluşturur ve bu aşağıdaki eşitlikle belirlenir. t= R C ln((v-vf)/(vi-vf)) (1) Eşitlikte; R seri direnci, V, t zamanındaki voltajı, Vi, başlangıç voltajını, Vf uygulanan voltajı göstermektedir. Kapasitans, bir geometrik faktörle aşağıdaki eşitlik kullanılarak toprağın dielektrik sabiti ile ilişkilendirilir. C=εo ε F (2) Eşitlikte; εo serbest ortamın dielektrik iletkenliği, ε toprağın dielektrik iletkenliğini göstermektedir. 1068

2. MATERYAL VE YÖNTEM Araştırma Akdeniz Üniversitesi Ziraat Fakültesi Tarımsal Yapılar ve Sulama bölümü laboratuvarında yürütülmüştür. Araştırmada materyal olarak killi tınlı ve kumlu bünyeye sahip iki toprak kullanılmıştır. Çalışmada kullanılan topraklara ilişkin özellikler Çizelge 1 de verilmiştir. Laboratuvara getirilen topraklar 2 mm lik elekten elenip kurutulduktan sonra doğal birim hacim ağırlığını sağlayacak şekilde 1.5 litrelik saksılara yerleştirilmiş ve 30 gün süre ile 0.7 (şebeke suyu, kontrol), 1.5, 3.0, 6.0 ve 12 ds/m olmak üzere beş farklı elektriksel iletkenliğe sahip su kullanılarak alttan doyurulmuştur. Toprakların istenilen düzeyde tuzlandığını kontrol etmek için boş bir leğene konulan saksılara üstten tuzlu su eklenmiş ve saksı altında çıkan suyun elektriksel iletkenlikleri ölçülerek giren suyun elektriksel iletkenliğine yaklaşık olarak eşit olduğu belirlenmiştir. Daha sonra 10HS toprak nem sensörü saksıların içerisine yerleştirilmiştir. Her bir konu üç tekerrürlü olacak şekilde düzenlenmiş toplamda 30 adet saksı kullanılmıştır. Toprağın doygun su içeriğinden solma noktası düzeyine kadar saksılar günlük olarak tartılmış ve aynı zamanda nemölçer ile toprak su içeriği milivolt biriminden ProCheck (Decagon) okuyucu ile ölçülmüştür. Toprak nem ölçümleri 24.07.2014 ile 01.09.2014 tarihleri arasında gerçekleştirilmiştir. Farklı elektriksel iletkenliğe sahip tuzlu sular musluk suyuna farklı miktarlarda NaCl ve CaCl2 tuzları eklenerek elde edilmiştir. Çizelge 1. Denemede kullanılan toprakların özellikleri Toprak bünyesi Hacim Ağ Kil, % Silt, % Kum, % TK (%) SN (%) Kum 1.58 4.5 1.5 94.0 8.5 2.0 Killi tın 1.16 48.7 27.6 23.7 27.0 13.8 3. BULGULAR VE TARTIŞMA Toprak bünyesi ve elektriksel iletkenliğe bağlı olarak elde edilen kalibrasyon eğrileri Şekil 1-5 te verilmiştir. Şekillerden de görüldüğü üzere her ikisi de mineral toprak olmasına rağmen toprak bünyesi üzerinde etkilidir. Aynı mv sensör okumasında toprak su içeriğinde iki katından da fazla farklı değerler elde edilebilmektedir. Söz konusu farklar tuzluluk düzeyi arttıkça artmaktadır. Örneğin, elektriksel iletkenliğin 0.7 ds/m olması durumunda 1300 mv sensör okumasında kumlu toprakta su içeriği 0.30 cm 3 /cm 3 iken killi tınlı toprakta 0.20 cm 3 /cm 3 değeri elde edilmektedir (Şekil 1). Elektriksel iletkenliğin 12 ds/m olmasındaki durumda ise aynı sensör okumasında kumlu toprak için 0.28 cm 3 /cm 3 killi tınlı toprak için 0.12 cm 3 /cm 3 değerleri elde edilmektedir (Şekil 5). 1069

Şekil 1. Killi tın ve kumlu toprak bünyesinde 0.7 ds/m elektriksel iletkenlik için Şekil 2. Killi tın ve kumlu toprak bünyesinde 1.5 ds/m elektriksel iletkenlik için Şekil 3. Killi tın ve kumlu toprak bünyesinde 3.0 ds/m elektriksel iletkenlik için 1070

Şekil 4. Killi tın ve kumlu toprak bünyesinde 6.0 ds/m elektriksel iletkenlik için Şekil 5. Killi tın ve kumlu toprak bünyesinde 12.0 ds/m elektriksel iletkenlik için Killi tınlı toprakta 0.7-12.0 ds/m elektriksel iletkenlik için elde edilen değerler topluca Şekil 6 da verilmektedir. Şekilden de görüldüğü üzere 0-6.0 ds/m elektriksel iletkenlik aralığında elde edilen veriler bir araya kümelenirken 12.0 ds/m elektriksel iletkenlik değeri diğerlerinden belirgin bir şekilde sapma göstermiştir. Bu nedenle killi tınlı toprakta 0.7-6.0 ds/m için bir kalibrasyon eğrisi 12 ds/m için ise ayrı bir kalibrasyon eğrisi düzenlenmiş ve Şekil 7 de verilmiştir. Decagon (2012) tarafından hazırlanan el kitabında mineral topraklarda toprak çözeltisi elektriksel iletkenliğinin 10 ds/m den küçük olması durumunda toprak su içeriğinin tuzluluktan etkilenmediği bildirilmektedir. Ancak Şekil 7 den de anlaşılacağı, üzere tuzluluk düzeyi 12.0 ds/m ye yükseldiğinde sensör okumaları tuzluluktan etkilenmektedir. Kumlu toprakta 0.7-12.0 ds/m elektriksel iletkenlik için elde edilen değerler topluca Şekil 8 de verilmektedir. Killi tınlı toprakla karşılaştırıldığında, kumlu toprakta elde edilen veriler tüm elektriksel iletkenlik değerleri için bir araya kümelenmiştir. O nedenle, 0.7-12.0 ds/m elektriksel iletkenlik değerleri için 1071

tek bir kalibrasyon eğrisi oluşturulmuş ve Şekil 10 da verilmiştir. Bu çalışmadan kumlu ve killi tınlı toprak için elde edilen nin Dacagon (2008) ve Decagon (2012) tarafından verilen ile karşılaştırılması Şekil 10 da verilmektedir. Hacimsel toprak su içeriğinin belirlenmesinde Decagon (2008) tarafından mineral topraklar için 10 ds/m ye kadar verilen eşitlik ikinci dereceden bir polinom şeklindedir (y=0.000000313x(mv) 2-0.000147x(mV)-0.0582). Decagon (2012) tarafından ise aynı eşitlik üçüncü dereceden bir polinom şeklinde verilmektedir (y=0.00000000117x(mv) 3-0.00000395x(mV) 2 +0.0049x(mV)-1.92). Şekilden de görüleceği üzere Dacagon (2008) tarafından verilen kalibrasyon eğrisi bu çalışmada kumlu toprak için elde edilen kalibrasyon eğrisi ile birbirine çok yakın iken Dacagon (2012) tarafından verilen kalibrasyon eğrisi ise hem kumlu toprak hem de killi tınlı toprak için bu çalışmadan elde edilen nden oldukça farklıdır. 4. SONUÇ Elde edilen sonuçlar birlikte değerlendirildiğinde, üretici firma tarafından önerilen ile bu çalışmadan elde edilen nin birbirinden oldukça farklı olduğu ve kullanılan suyun elektriksel iletkenliğinin üzerinde etkili olduğu sonucuna varılmıştır. Bu nedenle, toprağın dielektrik sabitine bağlı olarak geliştirilen kapasitans nem sensörlerinin toprak su içeriğini doğru bir şekilde belirleyebilmesi için kullanılacak topraklarda önceden mutlaka kalibre edilmesi gerekmektedir. Tuzlu su uygulamalarında bu daha da önem kazanmaktadır. Şekil 6. Killi tınlı topraktan farklı elektriksel iletkenlik değerleri için elde edilen hacimsel su içerikleri 1072

Şekil 7. Killi tınlı topraktan farklı elektriksel iletkenlik değerleri için elde edilen Şekil 8. Kumlu topraktan farklı elektriksel iletkenlik değerleri için elde edilen hacimsel su içerikleri Şekil 9. Kumlu topraktan farklı elektriksel iletkenlik değerleri için elde edilen kalibrasyon eğrisi 1073

Şekil 10. Killi tınlı ve kumlu toprak için elde edilen nin Dacagon (2008, 2012) tarafından verilen ile karşılaştırılması 5. KAYNAKLAR DECAGON (2008). 10HS Operator s Manual. Version 1. Decagon Devices, Inc., Pullman, WA. DECAGON (2012). 10HS Operator s Manual. Version 3. Decagon Devices, Inc.,Pullman, WA, DOBRIYAL P., QURESHI A., BADOLA R., HUSSAIN S.A. (2012). A Review of the Methods Available for Estimating Soil Moisture and Its Implications for Water Resource Management, Journal of Hydrology, 458, 110-117. USUL N. (2009). Engineering Hydrology. METU PRESS Publishing Company, Ankara, 404 p. 1074