LAN KABLO MONTAJI (YAPISAL KABLOLAMA)



Benzer belgeler
ŞEBEKE BAĞLANTILI GÜNEŞ ENERJİ SİSTEMLERİ SAHA DENETİM STANDARDLARI

YAPISAL KABLOLAMA SİSTEMLERİNİN İLGİLİ STANDARDLAR DOĞRULTUSUNDA TASARIMI VE UYGULAMA YÖNTEMLERİ

ŞEBEKE BAĞLANTILI GÜNEŞ ENERJİ SİSTEMLERİNDE SAHA DENETİMLERİ

SD 1200 Seviye Duyargası. Montaj ve Kullanım Kitapçığı

Türkiye'den Dünya'ya PARAFUDR KULLANMA KILAVUZU

GÜNEŞ PANELLERİNDE TOPRAKLAMA VE YILDIRIMDAN KORUNMA SİSTEMLERİ

NETbox HOME 19 Duvar Tipi KABİNETLER

SK 2400 On-Off Seviye Kontrolörü Montaj ve Kullanım Kitapçığı

NETbox HOME 19 Duvar Tipi KABİNETLER

SK 1200 Seviye Alarm Kontrolörü Montaj ve Kullanım Kitapçığı

Bakır Data Kabloları İçin Standartlar

HIZLI BAŞLANGIÇ KILAVUZU ISI POMPALI ISI GERİ KAZANIM CİHAZLARI VHR DX SERİLERİ

SD 2400 Seviye Duyargası. Montaj ve Kullanım Kitapçığı

ÖLFLEX 191 CY, UL/CSA AWM'li PVC kontrol kablosu, yağa dayanıklı, muhtelif uygulamalar için esnek ve perdelenmiş, UL/CSA: 600V

ÜRÜN BİLGİSİ ÖLFLEX 191 CY

ASMA TAVAN ÜSTLERİNDE VE DÖŞEMELERİN ALTINDA YANGIN ALGILAMASININ GEREKLİ OLDUĞU DURUMLAR VE UYGULAMALARI

J R04. Montaj kılavuzu. Geçerlilik alanı. Taşıma. Ön Ön. Çarpmaları önlemek için merdiven rulosu kullanın. Ön, baş üstü görüntü.

ÜRÜN BİLGİSİ. ETHERLINE PN FD Cat.5 M12. Bilgi PROFINET uygulamaları için (D-kodlu) İsteğe bağlı özel tipler için

ACİL DURUM ASANSÖRÜ ( İTFAİYE ASANSÖRÜ ) M. KEREM FETULLAHOĞLU MAKİNE MÜHENDİSİ

GRUP-EX ECS XX-YY ELECTRIC CURRENT SOLENOID - KULLANICI KILAVUZU -

Doküman No: KK-PS R2-TR CODESEC PS120 GÜÇ KAYNAĞI ÜNİTESİ KURULUM VE KULLANICI KILAVUZU. Doc: KK-PS R2-TR

Güvenlik Tamponu. Ürün bilgisi

SD 3400 Kapasitans Seviye Duyargası. Montaj ve Kullanım Kitapçığı

KULLANIM ALANLARI SERTİFİKALAR AÇIKLAMALAR

KULLANMA VE BAKIM KİTABI

Kurulum Kılavuzu. DEVIreg 130. Elektronik Termostat.

ÖNEMLİ GÜVENLİK AÇIKLAMALARI

PNOMEK. Safe pressure materials.. KULLANMA KILAVUZU PPS A SERİSİ

Ecras Elektronik Multimetre

Venüs Radar Sensörlü Led li Armatürler

AKSİYEL FAN HIZ KONTROL ÜNİTESİ

BD 5400 İletkenlik Duyargası. Montaj ve Kullanım Kitapçığı

Kurulum Kılavuzu. DEVIreg 132. Elektronik Termostat.

DEVIreg 330 (+5 ila +45 C)

AĞ ALTYAPISI KURULUMUNDA OKUL YÖNETİMLERİNİN DİKKAT ETMESİ GEREKLİ KONULAR

MAK-TES DOĞAL GAZ ISI SİSTEMLERİ HERMETİK BACA MONTAJ KILAVUZU

(FARADAY) KAFES TİPİ PARATONER TESİSATI TEKNİK ŞARTNAMESİ

EK-D GÜNEŞ ÖLÇÜM İSTASYONU KONTROL İŞLEMLERİ. Güneş Ölçüm İstasyonunda aşağıdaki meteorolojik değişkenler ve algılayıcının adı aşağıda verilmiştir.

ÜRÜN BİLGİSİ ÖLFLEX CLASSIC 110 H

ÜRÜN BİLGİSİ. UNITRONIC LiYCY. Faydalar Genel bakır örgü elektriksel paraziti en aza indirir Çok fonksiyonlu uygulama imkanları

SKV 3400 Seviye Kontrol Vanası Montaj ve Kullanım Kitapçığı

ÜRÜN BİLGİSİ N2XH. Norm referansları / Onaylar HD 604/VDE Sabit kurulum için 0,6/1 kv'lık nominal voltajlı halojensiz güç kablosu

Ürün no.: MSI Güvenlik kontrolü İçerik

Daha zorlu gereksinimler için EN (H05Z-K & H07Z-K) uyarınca VDE testi yapılmış tek damarlar

HT 500 HT HT HT

AKE MİKSER KONTROL KARTI-TEK HIZLI (7 SEG DOKUNMATİK YATAY TİP) KULLANIM KILAVUZU

Koaksiyel Kablo Koruyucuları Coaxiel Cable Protectors

Raychem. Uygulama Talimatı EPP /11-TR

Pek çok kimyasala karşı direnci kanıtlanmış, bütün hava koşullarına dayanıklı, ekranlı kontrol kablosu

1-Proje çizimi; Görsel performans,görsel konfor, enerji sarfiyatı ve maliyet yönünden verimlilik göz önünde bulundurularak aydınlatma yapılmalıdır.

İçindekiler. Sayfa. Uyarılar 1. Talimatlar 2. Açıklamalar 3. Ürün Bilgileri ve Tanıtımı 4. Dübel Özellikleri 5. Dübel ve Post Montajı 6

KAZIM EVECAN PCB Tasarımı ve EMC İlgilenenler İçin Önemli Bilgiler

İçerik. Ürün no.: MSI 410.F50-03 Güvenlik kontrolü

1.CİHAZ ÖLÇÜLERİ 2.CİHAZ BAĞLANTI ŞEMASI

ÖLFLEX CLASSIC PVC kontrol kablosu, VDE kayıtlı, çok çeşitli uygulamalar için yağa dayanıklı ve esnek, 300/500V, YSLY veya YY için de uygun

GÜNEŞ ENERJİLİ CEP TELEFONU ŞARJ CİHAZI KULLANMA KILAVUZU

Bilgi Teknolojileri için Parafudurlar Surge Protective Devices for IT Systems

ÖLFLEX Klasik muhtelif uygulamalar için renk kodlu ve esnek PVC kontrol kablosu, U 0 /U: 300/500V

RMS İSTASYONLARI NEDİR?

MLC 420 MANYETİK LİNEER CETVELLER KULLANMA KILAVUZU

ABO valve,s.r.o. Dalimilova 285/ Olomouc Czech Republic. Guvenlik Talimatı. Kurulum,İşletme Ve Bakım İçin ABO KELEBEK VANA MODEL 600,900

Yüksek Mukavemetli Düşük Alaşımlı Çeliklerin Kaynağı. Özlem Karaman Metalurji ve Malzeme Mühendisi Kaynak Mühendisi

JET FAN SİSTEM TASARIM KRİTERLERİ, MONTAJ VE DEVREYE ALMA UYGULAMALARI

Centronic UnitControl UC42 / UC45

MLC 310 KULLANMA KILAVUZU MANYETİK LİNEER CETVELLER KOMPAKT SİSTEM

1.CİHAZ ÖLÇÜLERİ 2.CİHAZ BAĞLANTI ŞEMASI

POLİÜRETAN TAMPON MONTAJ VE KULLANIM KILAVUZU

Optical Duplex patch cords with various types of connectors (ST, LC, SC) available in single-mode or multi-mode fibre version

sensör sensör çıkışı kontrol birimi Kontrol birimi, kontrol ekipmanı ve çıkış sinyali anahtarlama elemanından meydana gelir.

BANKET ARABASI (ELEKTRİKLİ)

RELAYrack. Açık sistem çatı D=600 - D=800 - D=1000. RELAYrack tekli çatı, D= 600 mm. RELAYrack çiftli çatılar, D= 800 mm

Kurulum Kılavuzu. DEVIreg 530. Elektronik Termostat.

biz kimiz. Simtes / Ostim

Ürün no.: MSI Güvenlik kontrolü İçerik

ELEKTRİKLE ÇALIŞMALARDA GÜVENLİK. Yıldırımdan korunma

Çıkış sinyali aktif notu

TOPRAKLAMA VE KORUMA ESASLARI.

1. Ana topraklama terminalleri veya çubukları 2. Elektrikli ekipmanların temasa açık iletken kısımları 3. Genel iletken parçalar.

Yüksek sıcaklıkta güç sınırlamalı ısıtma kablosu

17

MLC 410 MANYETİK LİNEER CETVELLER KULLANMA KILAVUZU

GRUP-EX PBB-XX-YY POWER BATTERY BOX - KULLANICI KILAVUZU -

Online teknik sayfa. ACM60B-S1KE13x06 ACM60 MUTLAK ENKODER

AKE GAZLI SABİT TABANLI FIRIN KONTROL KARTI (7 TFT DOKUNMATİK) KULLANIM KILAVUZU

ELEKTRİKLE ÇALIŞMALARDA İŞ SAĞLIĞI VE GÜVENLİĞİ TEDBİRLERİ

EMO T. Yüksek performanslı termoelektrik aktüatör ENGINEERING ADVANTAGE

%91.5Net Verim. Boru Eþanjörlü Sýcak Hava Üreteçleri. Her Dilde Kalitenin Adý TM

Montaj kılavuzu. Ağ geçidi opsiyon kutusu EKLONPG EKBNPG

Egzoz sisteminin modifiye edilmesi

Kurulum Yönergeleri. deviflex. DTIV içme suyu kablosu ısıtma kablosu 9 W/m içme suyu borularının donmaya

El Kitabı. MOVITRAC B Emniyetli Ayırma Uygulamalar. Baskı 06/ / TR

MONTAJ NOTLARI. MONTAJ VE BAKIM NOTLARI ACG-AltiLED KAÇ ADET ARMATÜR KULLANILMALI

Ürün özellikleri TBK AA2200. Tel : (86) Fax : (86)

Gaz Yakıtlı Sıcak Hava Üreteçleri

BKV 5400 Yüzey Blöf Kontrol Vanası Montaj ve Kullanım Kitapçığı

Teknik Bülten Baumit open Reflect Yalıtım Plakası

C38SS ÇELİK ÇELİK YÜKSELTİLMİŞ DÖŞEME SİSTEMİ TEKNİK ŞARTNAMESİ

MONTAJ İŞLETME ve BAKIM KILAVUZU ÇATI TİPİ FANLAR

İçerik. Ürün no.: MSI 430.F50-01 Güvenlik kontrolü

MONTAJ İŞLETME ve BAKIM KILAVUZU DİKDÖRTGEN KANAL TİPİ FANLAR

Transkript:

LAN KABLO MONTAJI (YAPISAL KABLOLAMA) Kamil MUTLU Nexans Türkiye Tuzla Fabrika Kalite Kontrol Müdürü kamil.mutlu@nexans.com ÖZET Kabloma standartları montaj kalitesinden emin olmak için yıllar içerisinde kablo üreticisine bakılmaksızın gelişime uğramıştır. Kablo montajında dikkate alınması gereken temel esaslara üreticinin ürün özellikleridir. Örneğin kablo bükülme yarıçapı ya da kablo bileşenleri gibi. Bundan dolayı standartlar kablo üreticilerinin ürün bilgilerinin de dikkate alınmasına atıfta bulunur. Kablolama Standartları: EN 50173-1:2011 Information technology - Generic cabling systems Part 1: General requirements EN 50173-2:2007/A1:2010 Information technology - Generic cabling systems - Part 2: Office premises EN 50173-3:2007/A1:2010 Information technology - Generic cabling systems - Part 3: Industrial premises EN 50173-4:2007/A2:2012 Information technology - Generic cabling systems - Part 4: Home EN 50173-5:2007/A2:2012 Information technology - Generic cabling systems - Part 5: Data Centres EN 50173-6:2014 Information technology - Generic cabling systems -Part 6: Distributed building services EN 50174-1:2009 /A1:2011 Information technology - Cabling installation-part 1: Specification and Quality Assurance EN 50174-1:2009 /A1:2011 Information technology - Cabling installation-part 2: Installation planning and practices inside buildings EN 50174-3:2013 Information technology - Cabling installation-part 3: Installation planning and practices outside buildings EN 50310:2010 Application of equipotential bonding and earthing in buildings with information technology equipment EN 50346:2002/A2:2009 Information technology - Generic cabling systems -Testing of installed cabling ISO 11801 edition 2.2:2011 Information Technology Generic Cabling for customer premises BS 6701:2010 Telecommunications equipment and telecommunications cabling - Specification for installation, operation and maintenance BS 7671:2008/A1:2011 Requirements for electrical installations: IEE Wiring Regulations: 17th edition ANSI/TIA/EIA-606-B-2011 Administration Standard for Commercial Telecommunications Infrastructure. ANSI/TIA-568-C.0-2012 Generic Telecommunications Cabling for Customer Premises ANSI/TIA-568-C.1-2012 Commercial Building Telecommunications Cabling Standard ANSI/TIA-568-C.2-2012 Balanced Twisted Pair Telecommunications Cabling and Components Standards ANSI/TIA-568-C.3-2012 Optical Fibre Cabling Components Standard

ANSI/TIA-569-C-2013 Commercial Building Standard for Telecommunications Pathways and Spaces ANSI/TIA-942-A-2012 Telecommunications Infrastructure Standard for Data Centres ANSI/TIA/EIA-570 Commercial Building Grounding and Bonding Requirements for Telecommunications LAN Kablo Tanımlama Kodları:

Kablolama Sistemi: Depolama: Tüm ekipmanlar için minimum ve maksimum depolama süresi ile sıcaklık ve nem şartları tanımlanmalıdır. Kablo datasheetlerinde verilen bilgiler dikkate alınmalıdır. Tüm kutular dik olarak stoklanmalı. Makaraların flanşları iç içe geçmemelidir. Eğer kablolar 4 haftadan daha fazla stokta bekletilecek ise uçları mutlaka neme karşı kep ile kapatılmalıdır. Makaraların hareket sahasında kabloya zarar verecek herhangi bir cismin olmadığından emin olunmalıdır. Numaralandırma ve Etiketleme: Mantıksal-sıralı numaralandırma Kablonun her iki ucununda etiketlenmesi Her prizin etiketlenmesi Aşağıdaki kayıtlar sağlanmalı: Kablolama Şeması Binanın yapısal kablolama planı İş Planı Patch Listesi Kabin Yerleşimi: Enerji hatlarından uzak durulmalıdır Merkezi ve kolay erişilebilir olmalıdır Gaz, su ve elektrik iletkenlerinden uzak durulmalıdır Maksimum uzunluk limitleri gözönünde bulundurulmalıdır Güvenli bir odada olmalı ya da kilitli olmalıdır

Kablo Çekimi: Kablolar çekim öncesi etiketlenmeli Kablo datasheetinde verilen bilgiler dikkate alınmalı Çekme Kuvveti Bükülme Yarıçapı (Montaj esnasında, işletme esnasında) Kablo alttan gelecek şekilde makaradan çekilmelidir. Çekim esnasında makara mutlaka sabitlenmelidir. Aynı anda en fazla 6 makara paralel olarak çekilmelidir. Kablo için verilen çekme kuvveti mutlaka önceden bilinmelidir. Çekim esnasında makaradan kaynaklanan kablo kılıfında herhangi bir hasar olup olmadığı kontrol edilmelidir. Mimimum bükülme yarıçapı dikkate alınmalı ve kablo bu noktalarda dikkatlice bükülerek çekim yapılmalıdır. Kablonun geçiş güzergahındaki tüm keskin noktalar ortadan kaldırılmalıdır. Datasheetlerde verilen minimum bükülme yarıçapına mutlaka dikkat edilmelidir.

Aşağıdaki tabloda örnek minimum bükülme yarıçapları verilmiştir: Kablolar, kablo bağı kullanılarak demetlenebilir Zarar vermekten kaçınmak için, kablo bağları çok fazla sıkılmamalıdır.

CAT 6 kablolarda, kablolara çok fazla baskı yapmaktan kaçınmak için geniş bant kullanılmalıdır. Kablo Güzergah Seçimi: Kablo güzergahı aşağıdaki kurallar dikkate alınarak seçilmelidir: Isı kaynaklarından kaçınılmalıdır(radyatör vb). Aşırı nemli ve titreşimin olduğu alanlardan kaçınılmalıdır. Kablolar bina yapısına uygun asma kablo kanalları-tavaları içerisinde kullanılmalıdır. Bina yapısına uygun olarak paralel ya da dik olarak döşenmelidir Kablo güzergahı bakımın kolay olması için yürüyüş güzergahına yakın olmalıdır. Kablo kanalının üzerinde min. 150mm boşluk olmalıdır. Kablo kanalının %50 si sonraki eklemeler vb. ihtiyaçlar için boş bırakılmalıdır. Yatayda maksimum 30 kablo döşenmesi önerilir. İdeal şartlarda maksimum 300mm yüksekliği geçmemelidir. Kablolar doğrudan beton zemin üzerine serilmemelidir. Tüm rotalarda kablo kanalı (ızgaralı) kullanılması olası su ve nem etkisinden koruyacaktır. Kablo kanalı ızgaralarınının boşluk ölçüsü 100mmX100m den fazla olmaması önerilir.

J tipi kanca kullanımı alttaki kablol üzerinde oluşan baskıdan dolayı tavsiye edilmemektedir. Kullanılması zorunlu ise 6 ya da daha az kablo kullanılmalıdır. İki kanca arası mesafe en fazla 500mm olmalıdır. Kablo Güzergahı ve Güç Kaynakları: Data kabloları ve güç kaynaklarını birbirinden ayırmak için iki ana sebep vardır: Koruma Elektrik Şoku riski Ekipmana zarar verme riski Enterferans Zayıf network performansı Data Kaybı EN 50174-2 kuralları İyi Uygulamalar Maksimum ayırma Alternatif güzergah kullanımı Ayrı topraklama sistemi Minimum Kural: EN 50174-2 standardının tüm gerekliliklerinin karşılanması EMI(Elektromanyetik Enterferans): EMI (Electromagnetic Interference) Kaynakları ve Gürültüler Makinalar Asansörler GSM / Walkie Talkie cihazları 230 V kablolama Yüksek Voltaj kabloları Havalandırma tesisatı Isıtma kaynakları / mikrodalga cihazları / radarlar Buzdolapları Fotokopi makinaları Ayarlı aydınlatma düğmeleri

Elektromanyetik Enterferansa karşı öneriler: Elektromanyetik Enterferansa karşı öneriler:

Kabin İçerisinde Kablolama-1: Kablolar minimum bükülme yarıçapına dikkat edilecek şekilde kabine girmelidir. Kablo koruyucu-sabitleyici aparatlar kablodan önce monte edilmiş olmalıdır. Kabine kabloların zarar vermemesine dikkat edilmelidir. Kablolar düzgün bir şekilde monte edilmelidir. Kabin İçerisinde Kablolama-2: Kablolar panellere olası hataların kolay bulunması için mantıksal bir sıralama ile bağlanmalıdır. Kablo demetleri panel içerisine diğer panellere zarar vermeyecek şekilde çıkartılabilir biçimde yerleştirilmelidir. Panellere 12 veya 24 kablo bağlanmalıdır. Kablo demetleri bağlanacağı panel ile aynı yükseklik seviyesinde olmalıdır.

Uygun Kablolama:

Uygun Olmayan Kablolama:

Gürültü Kaynakları: Ekranlama:

Sistemin tam olarak korunması için tüm ekipmanların ekranlanmış olması gerekmektedir. Topraklama(Earthing) EN50310 standardına göre yapılır.bu standartta eş-potansiyel topraklama sisteminin yapılmasını istenir. (1V r.m.s., düşük empedans).ancak Datacenter larda bu sağlanmaya çalışılsa da gerçek anlamda tam eş-potansiyel topraklama nadiren oluşturulabilir. Düşük frekans ekranlaması ancak Ferromanyetik malzemeler ile sağlanabilir. Earthing Grounding Grounding için büyük iletken bir plakanın toprağa gömülmesi ve sistemin bunu kullanması gerekir. Ekranlama: Topraklama (Earthing) sistemi aşağıda verildiği şekilde multimetre kullanılarak doğrulanmalıdır. Multimetre AC Voltaj Kontrolü, <1V a.c. rms = eş-potansiyel Multimetre direnç kontrolü eş-potansiyel topraklama için < 3.5 olmalı. Ekranlama ve Bina Topraklaması:

Topraklama (Earthing / Grounding) Kablonun Topraklanması-Earthing (Güvenlik için) sabitlenmeli ve devamlılık sağlanmalıdır. Güvenlik için ekran kullanılmayabilir ancak topraklama teli mutlaka kullanılmalıdır. Testler Tüm HF parametreleri montajdan etkilenir. Bundan dolayı ortaya ciddi etkiler çıkabilir. Bunlardan bazılarının nedenleri aşağıda verilmiştir. NEXT (Near End Cross Talk) : Kötü kablola çekimi, zayıf sonlandırma ELFEXT (Equal Level Far End Cross Talk): Kötü kablola çekimi, bükülme yarıçapı Zayıflama / Insertion Loss: Bükülme yarıçapı, çekme kuvveti Return Loss(Geri Dönüş Kaybı): Per/Öz hatvesinin bozulması, Nem Kablo Boyu: Test cihazları sinyalin iletim süresine göre kablo boyunu belirler. Gecikme süresi(delay) ve NVP(Nominal İletim Hızı) değerlerinden emin olunmalıdır. SONUÇ Tüm kablolarda olduğu gibi Yapısal Kabloların da tesisinin tüm aşamalarında ilgili yöntmelik ve standartlara uyulmalıdır. Bu bildiride bahsi geçen standartlar ve yöntemlere uyulması durumunda yapısal kabloların işletme performansı en üst düzeyde olacaktır. Bu durum işletme, ve ekipmanlarının güvenliğini garanti altına alınmasına da yardımcı olacaktır. KAYNAKLAR IEC internet sitesi CENELEC internet sitesi BS internet sitesi Amerikan Ulusal Standart internet sitesi(ansi) TSE internet sitesi İlgili yönetmelikler NEXANS LAN Kablo Genel Tesisat Rehberi