ATALETSEL ÖLÇÜM TEST HİZMETLERİ INERTIAL SENSOR TESTS AND 5.CALIBRATION SERVICES



Benzer belgeler
ÇEVRESEL TEST HİZMETLERİ 2.ENVIRONMENTAL TESTS

İTÜ DERS KATALOG FORMU (COURSE CATALOGUE FORM)

SBR331 Egzersiz Biyomekaniği

d h k d t s a t

PCC 6505 PROFILE CUTTING LINE

DÖRT ROTORLU BİR İNSANSIZ HAVA ARACININ İRTİFA KESTİRİMİ

ELDAŞ Elektrik Elektronik Sanayi ve Tic.A.Ş.

WEEK 11 CME323 NUMERIC ANALYSIS. Lect. Yasin ORTAKCI.

A UNIFIED APPROACH IN GPS ACCURACY DETERMINATION STUDIES

Dersin Kodu Dersin Adı Dersin Türü Yıl Yarıyıl AKTS

INCREMENTAL ROTARY ENCODERS Magnetic Measurement, 58 mm Body Diameter

C O N T E N T S BHD BHD page 2-5 BHD page 6-9 BHD page BHD page page BHD

EGETEST CENTER ELEKTRİK ELEKTRONİK SANAYİ VE TİCARET LİMİTED ŞİRKETİ

BOĞAZİÇİ UNIVERSITY KANDİLLİ OBSERVATORY and EARTHQUAKE RESEARCH INSTITUTE GEOMAGNETISM LABORATORY

THE DESIGN AND USE OF CONTINUOUS GNSS REFERENCE NETWORKS. by Özgür Avcı B.S., Istanbul Technical University, 2003

10 kn KAPASİTELİ KUVVET KALİBRASYON MAKİNASININ TASARIMI, İMALATI ve PERFORMANS ÖLÇÜMLERİ

: ALG Müh. ve Tic. Ahmet Lütfü Gönül ALG Su Laboratuvarı Sok. No: 90/205 El-Sel Sitesi Alsancak İzmir

Özel Tasarım Dişliler Custom Design Gears

LANDE DYNAcenter Server Cabinet W600 X D1000 MECHANICAL TESTS REPORT

Teşekkür. BOĞAZİÇİ UNIVERSITY KANDİLLİ OBSERVATORY and EARTHQUAKE RESEARCH INSTITUTE GEOMAGNETISM LABORATORY

Araziye Çıkmadan Önce Mutlaka Bizi Arayınız!

Yüz Tanımaya Dayalı Uygulamalar. (Özet)

PRELIMINARY REPORT. 19/09/2012 KAHRAMANMARAŞ PAZARCIK EARTHQUAKE (SOUTHEAST TURKEY) Ml=5.1.

t d h k d, t t s a t

Tuğra Makina bu katalogtaki tüm bilgiler üzerinde değișiklik yapma hakkı saklıdır. Tugra Makina all rights reserved to change all information in this

OFFSET ANTENNA OFSET ANTEN 65 cm. (60x66) ACCESSORIES - AKSESUARLAR

METOT VALİDASYONU VE VERİFİKASYONU. Sedat Abuşoğlu Konya

REDÜKTÖRLÜ GİYOTİN MAKAS ( MANYETİK FRENLİ ) GUILLOTINE SHEARS WITH REDUCER ( MAGNETIC BRAKE ) ( RGM / RGM )

Unlike analytical solutions, numerical methods have an error range. In addition to this

KALINTI GERİLME ÖLÇME LABORATUARI Vishay System 7000 Veri Toplama Merkezi

HİDROGRAFİK ÖLÇMELERDE ÇOK BİMLİ İSKANDİL VERİLERİNİN HATA ANALİZİ ERROR BUDGET OF MULTIBEAM ECHOSOUNDER DATA IN HYDROGRAPHIC SURVEYING

PİEZOELEKTRİK YAMALARIN AKILLI BİR KİRİŞİN TİTREŞİM ÖZELLİKLERİNİN BULUNMASINDA ALGILAYICI OLARAK KULLANILMASI ABSTRACT

TOLERANS DIŞINDA KALAN SES DÜZEYİ ÖLÇER TEPKİLERİNİN ÖLÇÜM SONUÇLARINA ETKİLERİ

Özel Tasarım Dişliler Custom Design Gears

SolarBaba2015: Solar Energy Conference GÜNEŞ ÖLÇÜM ⁹Ü NEDİR? NEDEN / NASIL YAPILIR? İSKENDER KÖKEY, MSc Country Manager, Turkey

İKİ KADEMELİ GAZ BRÜLÖRLERİ TWO STAGE GAS BURNERS

Beton Santralleri Concrete Batching Plants

Ege Üniversitesi Elektrik Elektronik Mühendisliği Bölümü Kontrol Sistemleri II Dersi Grup Adı: Sıvı Seviye Kontrol Deneyi.../..

İNKREMENTAL ROTARY ENKODERLER Yarı Hollow Şaft, 50 mm Gövde Çapı

İYC MADENCİLİK SAN. VE TİC. LTD. ŞTİ. NE AİT MUĞLA - FETHİYE YÖRESİ BEJ TÜRÜ KİREÇTAŞININ FİZİKO-MEKANİK ANALİZ RAPORU

ÖZET OTOMATİK KÖKLENDİRME SİSTEMİNDE ORTAM NEMİNİN SENSÖRLERLE HASSAS KONTROLÜ. Murat ÇAĞLAR

C6 Mugla White

C5 Mugla White

T.C. SÜLEYMAN DEMİREL ÜNİVERSİTESİ FEN BİLİMLERİ ENSTİTÜSÜ ISPARTA İLİ KİRAZ İHRACATININ ANALİZİ

EMC Test ve Kontrol Hizmetleri San. Tic. A.Ş. Hasköy Sanayi Sitesi İdari Bina No:13 Gebze KOCAELİ / TÜRKİYE

[Emerald XS 30 4 C ] Data Sheet.

Prima was founded in1994. It is the first private MRO established in Turkey. It serves within it s new facilities at Atatürk Airport on 3765 m²

THE EFFECT TO GEOREFERENCING ACCURACY OF CONTROL TARGETS IN TERRESTRIAL LASER SCANNING APPLICATIONS

Konforun Üç Bilinmeyenli Denklemi 2016

AĞIR YAĞ SIVI YAKIT BRÜLÖRLERİ FUEL OIL BURNERS

KALEIDOSCOPES N.1. Solo Piano. Mehmet Okonşar

Dersin Kodu Dersin Adı Dersin Türü Yıl Yarıyıl AKTS. BUHAR KAZANLARI Seçmeli 4 7 3

AUTOMATIC POWER FACTOR CONTROLLER REAKTİF GÜÇ KONTROL RÖLESİ. Shreem Capacitors Pvt. Ltd. AFB Enerji Mühendislik Ltd. Şti.

ORANSAL GAZ BRÜLÖRLERİ MODULATED GAS BURNERS

Arýza Giderme. Troubleshooting

FARK BASINÇ ÖLÇERLERİN KALİBRASYONLARI

SÜRGÜLÜ VANA (F4) RESILIENT SEATED GATE VALVE (F4)

Numune Kodu ve parti no

Ulusal Metroloji Enstitüsü GENEL METROLOJİ

POLİMER KOMPOZİT TEST YÖNTEMLERİ

BOĞAZİÇİ UNIVERSITY KANDİLLİ OBSERVATORY and EARTHQUAKE RESEARCH INSTITUTE GEOMAGNETISM LABORATORY

Linear Lighting Fixtures Linero Mini 36

Keyestudio SHT31 Temperature and Humidity Module / SHT31 Sıcaklık ve Nem Modülü

Tekirdağ&Ziraat&Fakültesi&Dergisi&

DENEY VE KALİBRASYON MERKEZİ BAŞKANLIĞI Doküman No YT-FR-018. Deney Metodu Test Method

Calacatta Oro

PACKAGE STITCHING SYSTEMS KOLİ DİKİŞ SİSTEMLERİ. MAKİNA SAN.TİC.LTD.ŞTİ KOLİ DİKİŞ MAKİNALARI ve DİKİŞ TELİ İMALATI GÜVENİLİR ÜRETİMDE DOĞRU TERCİH

INERTIAL MEASUREMENT UNITS FOR MOTION CONTROL OF SURGICAL ENDOSCOPIC ROBOT

POSITION DETERMINATION BY USING IMAGE PROCESSING METHOD IN INVERTED PENDULUM

Performans Tabloları Yalınkat Camlar

GEAsystem. İnşaat mühendisliğinde vibrasyon ölçümleri için etkin çözümler. w w w. s e q u o i a. i t

THE CHANNEL TUNNEL (MANŞ TÜNELİ) Hilmi Batuhan BİLİR Deniz Göksun ATAKAN İlayda YEĞİNER

FLEXIS MULTMULTİFONKSİYONEL ŞARJ CİHAZI. Programlanabilir, yüksek frekanslı, modüler traksiyoner akü şarj cihazları

Dersin Kodu Dersin Adı Dersin Türü Yıl Yarıyıl AKTS MAKİNA PROJESİ II Zorunlu 4 7 4

Özel Tasarım Redüktörler Custom Design Gearboxes

Tahrik aktarma sistemleri Helezon dişlili tabla rulmanları (sonsuz göbek dişlisi) İMALAT MAKİNA RULMANLARI

ESTA Oscillation Sönümleme Elemanları Anti-vibration Mounts kalıte / qualıty tasarım / desıng teknolojı / technology

Onarge Teknoloji Medikal Sistemler Sanayi Ticaret Limited Þirketi Onarge Technology Medical Systems Industry Comm. Co. Ltd.

Mitsubishi Electric Corporation. Number of Items

T.C. İSTANBUL AYDIN ÜNİVERSİTESİ SOSYAL BİLİMLER ENSTİTÜSÜ BİREYSEL DEĞERLER İLE GİRİŞİMCİLİK EĞİLİMİ İLİŞKİSİ: İSTANBUL İLİNDE BİR ARAŞTIRMA

Atıksu Arıtma Tesislerinde Hava Dağıtımının Optimize Edilmesi ve Enerji Tasarrufu

High Bay Lighting Fixtures Saver Premium HB 80

= σ ε = Elastiklik sınırı: Elastik şekil değişiminin görüldüğü en yüksek gerilme değerine denir.

$5$ù7,50$ (%(/ø. gö5(1&ø/(5ø1ø1 *g5(9 7$1,0/$5, 9( <(7(5/ø/ø. $/$1/$5,1$ *g5(.(1'ø/(5ø1ø '(ö(5/(1'ø50(/(5ø g]hq (VUD.$5$0$1 + O\D 2.

GMC FCU-097 ÜRÜNLERİ ÖZELLİKLERİ:

24kV,630A Outdoor Switch Disconnector with Arc Quenching Chamber (ELBI) IEC IEC IEC 60129

METAL SANAYİ VE TİC. LTD. ŞTİ.

ATILIM UNIVERSITY Department of Computer Engineering

1. Giriş. 2. Dört Rotorlu Hava Aracı Dinamiği 3. Kontrolör Tasarımı 4. Deneyler ve Sonuçları. 5. Sonuç

KABLO DÖŞEME GEMİLERİ CABLE LAYING VESSELS

TEK KADEMELİ GAZ BRÜLÖRLERİ SINGLE STAGE GAS BURNERS

Mobile Surveillance Vehicle

VTEC MUSTEK CNC FREZE - ROUTER TEZGAHLARI VTEC MUSTEK CNC MILING AND ROUTER MACHINES

POMPA VE MOTOR PUMPS AND MOTORS

DN MERMER FİRMASINA AİT BALLIK BOĞAZI BÖLGESİ TRAVERTENİNİN ANALİZ RAPORU

WEEK 4 BLM323 NUMERIC ANALYSIS. Okt. Yasin ORTAKCI.

97/23/AT BASINÇLI EKİPMANLAR YÖNETMELİĞİ BAŞVURU BİLGİ FORMU INFORMATION FORM FOR 97/23/EC PRESSURE EQUIPMENT DIRECTIVE

4. HAFTA BLM323 SAYISAL ANALİZ. Okt. Yasin ORTAKCI.

SERTLĐK ELMAS UÇLARI KALĐBRASYONU LABORATUVARLAR ARASI KARŞILAŞTIRMASI TEKNĐK PROTOKOLÜ

TİTREŞİM UYARICISI KALİBRASYONU KONUSUNDA ULUSAL DÜZEYDE LABORATUVARLAR ARASI KARŞILAŞTIRMA

Transkript:

ATALETSEL ÖLÇÜM TEST HİZMETLERİ INERTIAL SENSOR TESTS AND 5.CALIBRATION SERVICES Ataletsel Ölçüm Laboratuvarında, seyrüsefer ve güdüm sistemlerinde kullanılan Dönüölçer, İvmeölçer, Ataletsel Ölçüm Birimi (AÖB) ve Ataletsel Seyrüsefer Sistemi (ANS) için gerekli test ve kalibrasyonlar laboratuar olanakları dahilinde yapılmaktadır. Inertial Sensor Laboratory serves to provide testing and calibration of Inertial Navigation System (INS), Inertial Measurement Unit (IMU), accelerometer and gyroscope used for navigation and guidance systems. 44 45

Ataletsel Ölçüm Laboratuvarı (AÖL) TÜBİTAK- SAGE nin en eski altyapılarından olup 1994 yılında Savunma Sanayi Müsteşarlığı nın katkılarıyla Orta Doğu Teknik Üniversitesi yerleşkesinde Güdüm Kontrol Laboratuarının (GKL) bir parçası olarak kurulmuştur. Bu altyapıda, Türkiye deki birçok firma ile çalışılmış ve bir çok projeye ait ataletsel ölçer veya birim testleri yapılmıştır. Altyapıda ISO 9001:2000 kalite yönetim sistemi uygulanmaktadır. Altyapıda Bulunan Cihazların Teknik Özellikleri Üç Eksenli Hareket Benzetimci Konum çözünürlüğü : 0.00001 Konum doğruluğu : < 1 arcsec (< 0.0003 ) Açısal hız çözünürlüğü : 0.00001 /s Açısal hız kararlılığı : 0.0001 % En yüksek hız : 1000 /s (iç eksen); 750 /s (orta eksen); 500 /s (dış eksen) En yüksek ivme : 1660 /s 2 (iç eksen); 590 /s 2 (orta eksen); 660 /s 2 (dış eksen) Sıcaklık kontrolü :-55 +85 C İki Eksenli Hareket Üreteci Konum çözünürlüğü 0.00001 Konum doğruluğu : < 1 arcsec (< 0.0003 ) Açısal hız çözünürlüğü : 0.0001 /s Açısal hız kararlılığı : ± 0.0002% < 400 /s; ± 0.0005% < 1000 /s En yüksek hız : 1000 /s (iç eksen); 400 /s (dış eksen) En yüksek ivme : 2700 /s 2 (iç eksen); 260 /s 2 (dış eksen) Maksimum test edilebilir yük : 40 kg Sıcaklık kontrolü : -60 +90 C Santrifüj Cihazı Konum çözünürlüğü : 0.00001 Konum doğruluğu : < 1 arcsec (< 0.0003 ) Açısal hız çözünürlüğü : 0.00001 /s Açısal hız kararlılığı : 0.0001 % Maksimum açısal hız : 4000 /s Doğrusal ivme aralığı : 0.5 200 g Maksimum test edilebilir yük : 10 kg Test odası sıcaklık aralığı : -60 C ile 125 C İndeks Tablası Konum doğruluğu : 0.25 arcsec Tekrarlanabilirliği : 0.05 arcsec Konum kararlılığı : 0.025 arcsec Ortogonallik : 2 arcsec Konum çözünürlüğü : 1.0 deg Yükleme Limiti : 10 lbs Yükseklik x en x çap : 2620 x 1755 x 1219 mm Ağırlık : 310 lbs Inertial Sensor Laboratory (AÖL) is the oldest infrastructure of TUBİTAK-SAGE, located in the campus of Middle East Technical University. Laboratory was founded in 1994 by Under Secretariat for Defense Industries as part of the Guidance and Control Laboratory. We have been collaborated with many companies in country and performed tests of various kinds of inertial sensors and inertial measurement units in the laboratory. Laboratory work has been carried out according to ISO 9001:2000 Quality Management System. Technical Specifications of Instruments Three axis motion simulator Positioning resolution : 0.00001 Positioning accuracy : < 1 arcsec (< 0.0003 ) Rate resolution : 0.00001 /s Rate stability : 0.0001 % Max. rate : 1000 /s (Inner axis); 750 /s (Middle axis); 500 /s (Outer axis) Max. acceleration : 1660 /s 2 (Inner axis); 590 /s 2 (Middle axis); 660 /s 2 (Outer axis) Temperature chamber range :-55 to +85 C. Two axis position / rate table Positioning resolution : 0.00001 Position accuracy : < 1 arcsec (< 0.0003 ) Rate resolution : 0.0001 /s Rate stability : ± 0.0002% < 400 /s; ± 0.0005% < 1000 /s Max. rate : 1000 /s (Inner axis); 400 /s (Outer axis) Max. acceleration : 2700 /s 2 (Inner axis); 260 / s 2 (Outer axis) Payload Capacity : 40 kg Temperature chamber range : -60 to +90 C Centrifuge Positioning resolution : 0.00001 Positioning accuracy : < 1 arcsec (< 0.0003 ) Rate resolution : 0.00001 /s Rate stability : 0.0001 % Rate range: 4000 /s Linear acceleration range : 0.5 200 g Payload Capacity : 10 kg Temperature chamber range : -60 C to 125 C. Manual index table Positioning accuracy : 0.25 arcsec Repeatability : 0.05 arcsec Position stability : 0.025 arcsec Orthogonality : 2 arcsec Positioning resolution : 1.0 deg Payload Capacity : 10 lbs Dimensions (HxWxD) : 2620 x 1755 x 1219 mm Weight : 310 lbs. 46 47

Kapsadığı Standartlar / Şartnameler IEEE Std. 528 2001 : Standard for Inertial Sensor Terminology. IEEE Std. 1293 1998 : Standart Specification Format Guide and Test Procedure for Linear Single-Axis, Nongyroscopic Accelerometers. IEEE Std. 836 2001 : Recommended Practice for Precision Centrifuge Testing of Linear Accelerometers. IEEE Std. 952 1997 (R2002) : IEEE Standart Specification Format Guide and Test Procedure for Single-Axis Interferometric Fiber Optic Gyros. IEEE Std. 529 1980 (R2005) : IEEE Standart Supplement for Strapdown Applications to IEEE Standart Specification Format Guide and Test Procedure for Single-Degree-of-Freedom Rate-Integrating Gyros. IEEE Std. 674 1995 : IEEE Standart for Linear Single-Axis Laser Gyros. IEEE Std. 813 1988 (R2005) : IEEE Standart for Two-Degree-of-Freedom Dynamically Tuned Gyros. 5.1. İvmeölçer Test ve Kalibrasyonu Bu testler ile ivmeölçer teknik özellikleri doğrulanabilir ve her ivmeölçere ait kalibrasyon parametreleri bulunabilir. Bu parametrelerin kararlılığı ve değişen sıcaklığa bağlı olarak değişimi hesaplanabilir. Bu testler Allan Varyans Testleri ve Kalibrasyon Testleri olarak iki kısma ayrılır. Allan Varyans Testleri Bu testler durağan durumdaki ölçerlerden, uzun süreli (saatler seviyesinde) veri alınarak gerçekleştirilmektedir. Alınan bu ölçer verilerinin grup ortalamalarının farklarına dayalı işlem sonucunda çizilen grafikten, gürültü kaynaklı değişik hatalar hesaplanır. Hesaplanan hatalar şunlardır: nicemleme gürültüsü hız rastgele yürüme sabit kayma kararsızlığı uzun süre gürültüsü. Standards/Specifications IEEE Std. 528 2001 : Standard for Inertial Sensor Terminology. IEEE Std. 1293 1998 : Standart Specification Format Guide and Test Procedure for Linear Single-Axis, Nongyroscopic Accelerometers. IEEE Std. 836 2001 : Recommended Practice for Precision Centrifuge Testing of Linear Accelerometers. IEEE Std. 952 1997 (R2002) : IEEE Standart Specification Format Guide and Test Procedure for Single-Axis Interferometric Fiber Optic Gyros. IEEE Std. 529 1980 (R2005) : IEEE Standart Supplement for Strapdown Applications to IEEE Standart Specification Format Guide and Test Procedure for Single-Degree-of-Freedom Rate-Integrating Gyros. IEEE Std. 674 1995 : IEEE Standart for Linear Single-Axis Laser Gyros. IEEE Std. 813 1988 (R2005) : IEEE Standart for Two-Degree-of-Freedom Dynamically Tuned Gyros. 5.1. Accelerometer Tests and Calibration Technical specifications of accelerometer can be verified and calibration parameters can be found by accelerometer tests. Stability and temperature dependency of calibration parameters can be calculated also. These tests are divided into two parts. First part is Allan variance tests and second part is calibration tests. Allan Variance Tests Data should be taken for long time (for hours) without giving input to the accelerometer. Allan variance is the average of the variance of adjacent pairs of elements in a contiguous time series of data versus the averaging time used to generate the elements. Allan variance results are related to basic sensor noise terms given below: quantization noise velocity random walk bias instability rate ramp. Allan varyans testleri, indeks tablası, üç eksenli hareket benzetimci, iki eksenli hareket üreteci kullanılarak yapılabilmektedir. Allan variance tests are performed by using indexing table (or dividing head), two axis position/rate table, three axis motion simulator. 48 49

Kalibrasyon Testleri Her ivmeölçer ayrı ayrı kalibrasyon testlerine girer. Kalibrasyon testleri ihtiyaca göre indeks tablası, santrifüj cihazı, üç eksenli hareket benzetimci ve/ veya 2 eksenli hareket üreteci cihazlarından uygun olanlar kullanılarak ivmeölçere yüksek hassasiyetli ivme girdileri uygulanarak yapılır. Kalibrasyon testleri, konum testleri ve santrifüj testleri olarak ayrılabilir. Konum testleri; indeks tablası, üç eksenli hareket benzetimci, iki eksenli hareket üreteci cihazlarını kullanarak yapılabilmektedir. Konum testlerinde ivmeölçere ±1 g aralığında yerçekimi ivmesi bileşenleri uygulanmaktadır. Bu konum testleri sonucunda ivmeölçerler için sabit kayma, orantı katsayısı ve açı kayması değerleri hesaplanır. Santrifüj testleri ile ise yüksek ivme değerleri altında orantı katsayısı ve orantı katsayısı doğrusallığı ivmeölçer ölçme aralığı boyunca hesaplanır. Hesaplanan bu katsayılar ile ölçerlere ait kalibrasyon matrisi oluşturulur. Bu matris AÖB veya seyrüsefer yazılımlarına girdi olmaktadır. Bu testlerin ardından ayrıntılı olarak farklı sıcaklıklarda kalibrasyon testleri tekrar edilebilir. Böylelikle parametrelerin sıcaklığa bağlı olarak değişimi ve tekrarlanabilirliği test edilir. Uygulamalar MEMs (Mikro-Elektro-Mekanik Sistemler) yapılı veya sarkaç yapılı quartz ivmeölçerlere bu testler uygulanabilmektedir. Gerekli Örnek Özellikleri ve Örnek Teslim Şartları Test edilecek ivmeölçerlerin test edileceği uygun cihaz seçildikten sonra uygun test düzeneğinin kurulması gerekmektedir. Bu test düzeneği, ölçerin cihazın içine yerleşimini sağlayacak mekanik arayüzü, ölçer verilerinin bilgisayara slipringler üzerinden veya başka bir yolla aktarılmasını sağlayacak elektriksel arayüzü ve/veya gerekli yazılımı içermektedir. Gerekli test düzeneği kurulduktan sonra ölçere uygun test planı hazırlanıp ölçümler yapılır. Yapılan testler Test Sonuç Raporu ile raporlanmaktadır. Calibration Tests Each accelerometer is calibrated separately by these tests. Calibration tests can be performed by using index table, centrifuge, two axis position/rate table and three axis motion simulator. Highly sensitive inputs can be given to the accelerometer using those equipments. Calibration tests are divided into two parts as position tests and centrifuge tests. Position tests can be performed by using index table, two axis position/rate table or three axis motion simulator. Table is tumbled through a series of positions to apply components of local gravity vector in the range of ±1 g. Bias, scale factor and misalignments can be calculated as a result of position tests. Scale factor can be calculated during centrifuge tests for all measurement range of the accelerometer. Accelerometer calibration matrix is constituted with these calculated parameters and this matrix can be used by navigation process and IMU software. Calibration tests can be repeated to find the temperature dependence of the calibration parameters. Applications Accelerometer tests can be applied to quartz pendulum type and MEMs (Micro-Electro- Mechanical Systems) type accelerometers. Sample Requirements Suitable test setup for accelerometer testing should be selected and configured. This test setup should mainly include sensor mounting fixture, software and electronic equipment required to operate accelerometer and measure its output. After the test setup is complete, test plan is prepared and the results of all measurements are reported. 50 51

5.2. Dönüölçer Test ve Kalibrasyonu Bu testler ile dönüölçer teknik özellikleri doğrulanabilir ve her dönüölçere ait kalibrasyon parametreleri bulunabilir. Bu parametrelerin kararlılığı ve değişen sıcaklığa bağlı olarak parametrelerin değişimi hesaplanabilir. Bu testler Allan Varyans Testleri ve Kalibrasyon Testleri olarak iki kısma ayrılır. Allan Varyans Testleri Bu testler durağan durumdaki ölçerlerden, uzun süreli (saatler seviyesinde) veri alınarak gerçekleştirilmektedir. Alınan bu ölçer verilerinin grup ortalamalarının farklarına dayalı işlem sonucunda çizilen grafikten, gürültü kaynaklı değişik hatalar hesaplanır. Hesaplanan hatalar şunlardır: nicemleme gürültüsü açı rastgele yürüme sabit kayma kararsızlığı uzun süre gürültüsü. Dönüölçer Allan Varyans testleri, indeks tablası, üç eksenli hareket benzetimci, iki eksenli hareket üreteci kullanılarak yapılabilmektedir. Kalibrasyon Testleri Her dönüölçer ayrı ayrı kalibrasyon testlerine girer. Kalibrasyon testleri ile her dönüölçere ait parametreler hesaplanmaktadır. Kalibrasyon testleri, üç eksenli hareket benzetimci veya iki eksenli hareket üreteci kullanılarak yapılabilmektedir. Bu testler sırasında dönüölçere yüksek hassasiyetli dönü girdileri uygulanır. Bu girdi değerleri dönüölçerin ölçüm aralığı dikkate alınarak yapılmaktadır. Dönü testleri sonucunda dönüölçerler için orantı katsayısı, açı kaymaları değerleri ve hataları hesaplanır. Sıfır girdi uygulayarak ise sabit kayma değerleri hesaplanır. Hesaplanan bu katsayılar ile ölçerlere ait kalibrasyon matrisi oluşturulur. Bu matris AÖB veya seyrüsefer yazılımlarına girdi olmaktadır. Bu testlerin ardından ayrıntılı olarak farklı sıcaklıklarda kalibrasyon testleri tekrar edilebilir. Böylelikle parametrelerin sıcaklığa bağlı olarak değişimi ve tekrarlanabilirliği test edilir. Uygulamalar Fiber optik, lazer yapılı, titreşen yapılı ve MEMs yapılı dönüölçerlere bu testler uygulanabilir. Gerekli Örnek Özellikleri ve Örnek Teslim Şartları Test edilecek dönüölçerlerin test edileceği uygun cihaz seçildikten sonra uygun test düzeneğinin kurulması gerekmektedir. Bu test düzeneği, ölçerin cihazın içine yerleşimini sağlayacak mekanik arayüzü, ölçer verilerinin bilgisayara slipringler üzerinden veya başka bir yolla aktarılmasını sağlayacak elektriksel arayüzü ve/veya gerekli yazılımı içermektedir. Gerekli test düzeneği kurulduktan sonra ölçere uygun test planı hazırlanıp ölçümler yapılır. Yapılan testler Test Sonuç Raporu ile raporlanmaktadır. 5.2. Gyroscope Tests and Calibration Technical specifications of gyroscope can be verified and calibration parameters can be found by these tests. Stability and temperature dependency of calibration parameters can be calculated with gyroscope tests also. These tests are divided into two parts. First part is Allan variance tests and second part is calibration tests. Allan Variance Tests Data should be taken for long time (for hours) without giving input to the gyroscope. Allan variance is the average of the variance of adjacent pairs of elements in a contiguous time series of data versus the averaging time used to generate the elements. Allan variance results are related to basic sensor noise terms given below: quantization noise angle random walk bias instability rate ramp. Allan variance tests are performed by using indexing table (or dividing head), two axis position/rate table, three axis motion simulator. Calibration Tests Each gyroscope is calibrated separately by these tests. Calibration tests can be performed by using two axis position / rate table or three axis motion simulator Highly sensitive rate inputs can be given to the gyroscope using these equipments. Measurement range of the gyroscopes has been considered for the test inputs. Gyroscopes scale factor, misalignments and errors can be calculated as a result of rate inputs in all measurement range of gyroscope. Bias value is calculated by precision positioning of gyroscopes. Gyroscope calibration matrix is constituted with this calculated parameters and this matrix can be used during navigation process and IMU software. Calibration tests can be repeated to find the temperature dependence of the calibration parameters. Applications These tests can be applied to fiber-optic, laser and MEMs (Micro-Electro-Mechanical Systems) and vibrating types of gyroscopes. Sample Requirements Suitable test setup for gyroscope testing should be selected and configured. This test setup mainly includes sensor mounting fixture, software and electronic equipment required to operate gyroscope and measure its output. After the test setup is complete, test plan is prepared and the results of all measurements are reported. 52 53

5.3. Ataletsel Ölçüm Birimi (AÖB) Testi Uygulamalar Bu testler güdüm kontrol, seyrüsefer sistemlerinde kullanılan AÖB lere uygulanabilir. 5.3. Inertial Measurement Unit (IMU) Tests Ataletsel seyrüsefer başarımını arttırmak için tasarım IMUs can be tested in detail which is necessary aşamasında AÖB lerle ayrıntılı testler yapılır. Gerekli Örnek Özellikleri ve Örnek Teslim Şartları during the design and development stage of Öncelikle Allan Varyans testleri yapılarak ölçerlerin Test edilecek Ataletsel Ölçüm Biriminin test navigation systems. At first, Allan Variance genel başarımı incelenir. Daha sonra her dönüölçer ve ivmeölçere ait parametrelerin hesaplanması için kalibrasyon testleri yapılır. edileceği uygun cihaz seçildikten sonra uygun test düzeneğinin kurulması gerekmektedir. Bu test düzeneği, AÖB nin cihazın içine yerleşimini sağlayacak mekanik arayüzü, ölçer verilerinin tests are performed and investigated for understanding general performance of sensors. Later, accelerometers and gyroscopes calibration parameters are found with the calibration tests. Allan Varyans Testleri Bu testler durağan durumdaki ivmeölçerler ve dönüölçerlerden, uzun süreli ( saatler seviyesinde) veri alınarak gerçekleştirilmektedir. Alınan bu ölçer verilerinin grup ortalamalarının farklarına dayalı işlem sonucunda çizilen grafikten, gürültü kaynaklı değişik hatalar hesaplanır. Hesaplanan hatalar şunlardır: nicemleme gürültüsü açı rasgele yürüme sabit kayma kararsızlığı hız rasgele yürüme uzun süre gürültüsü. bilgisayara slipringler üzerinden veya başka bir yolla aktarılmasını sağlayacak elektriksel arayüzü ve/veya gerekli yazılımı içermektedir. Gerekli test düzeneği kurulduktan sonra ölçere uygun test planı hazırlanıp ölçümler yapılır. Yapılan testler Test Sonuç Raporu ile raporlanmaktadır. Allan Variance Tests Data should be taken for long time (for hours) without giving input to the IMU. Allan variance is the average of the variance of adjacent pairs of elements in a contiguous time series of data versus the averaging time used to generate the elements. Allan variance results are related to basic sensor noise terms given below: quantization noise angle random walk bias instability rate random walk rate ramp. Sample Requirements Suitable test setup for testing IMU should be Kalibrasyon Testleri Bu testlerle AÖB içinde kullanılan ölçerlerin hata modelleri oluşturulur. Her AÖB üretildikten sonra ayrı ayrı kalibrasyon testlerine girer. Kalibrasyon testleri üç eksenli hareket benzetimci veya iki eksenli hareket üreteci kullanılarak AÖB ye yüksek hassasiyetli ivme ve dönü girdileri uygulanarak yapılır. Calibration Tests Error models of inertial sensors used in IMU are calculated with calibration tests. Each IMU is calibrated separately. Calibration tests can be performed by using two axes position/rate table or three axes motion simulator. Highly sensitive rate and acceleration inputs can be given to the IMUs using these equipments. As a result of position tests, bias, scale factor and misalignments selected and configured. This test setup mainly includes IMU mounting fixture, software and electronic equipment required to operate IMU and measure its sensors output. After the test setup is complete, test plan will be prepared and all measurements results will be reported. Konum testleri sonucunda ivmeölçerler için sabit kayma, orantı katsayısı ve açı kaymaları değerleri; dönüölçerler için ise sabit kayma değerleri bulunur. Dönü testleri sonucunda dönüölçerlerin orantı katsayıları ve açı kaymaları hesaplanır. Hesaplanan bu katsayılar ile ölçerlere ait parametreleri içeren kalibrasyon matrisi oluşturulur. Bu matris AÖB veya seyrüsefer yazılımlarına girdi olmaktadır. of accelerometer and bias of gyroscopes are calculated. Gyroscope and accelerometer calibration matrix are constituted with these calculated parameters and this matrix can be used during navigation process and IMU software. Calibration tests can be repeated to find the temperature dependence of the calibration parameters. Bu testlerin ardından ayrıntılı olarak farklı sıcaklıklarda kalibrasyon testleri tekrar edilebilir. Böylelikle parametrelerin sıcaklığa bağlı olarak değişimi ve tekrarlanabilirliği test edilir. Applications These tests can be applied to IMUs used for navigation and guidance control systems. 54 55