Montaj ve Kullanım Kılavuzu Device Work Schedule Einbau-und Benutzerhandbuch



Benzer belgeler
Montaj ve Kullanım Kılavuzu Device Work Schedule Einbau-und Benutzerhandbuch

PANO KLİMA SİSTEMLERİ ENCLOSURE COOLING SYSTEMS

TAV FIRINI/ANNEALING FURNACE KULLANMA KLAVUZU / USER'S GUIDE

: Shower Unit (Flat) : Kompakt Duș Ünitesi (Flat)

AKE Bulaşık Yıkama Makinası Kontrol Kartı Kullanım Kılavuzu Dishwasher Controller User Manual TR EN

aircoolers Evaporatörler Aircoolers TAVAN TİPİ EVAPORATÖRLER CEILING TYPE AIR COOLERS DUVAR TİPİ EVAPORATÖRLER WALL TYPE AIR COOLERS

POLİÜRETAN TAMPON MONTAJ VE KULLANIM KILAVUZU

AQUARIUM ACCESSORIES

Zest. : Shower Unit (Flat) Kompakt Duş Ünitesi (Flat) Description Tan m. : 90x90. Size / Ebat (cm) : 2.5. Depth / Derinlik (cm) Weight / A rl k (kg)

Sirkülasyon Pompaları

AKE.ZR Yıkama Durulama Zaman Rölesi Kullanım Kılavuzu Washing and Rinse Time Relay User Manual TR EN

VERSİYON A1.0. Cihaz Defrost konumunda

H48.33b FILTER DRIER SHELLS KARTUŞ KOVANLARI. H48.33b.54.1

PCC 6505 PROFILE CUTTING LINE

VHR ER ENERJİ GERİ KAZANIM CİHAZLARI VHR ER ENERGY RECOVERY UNITS

STANDART ÖZELLİKLER STANDARD FEATURES OPTIONAL FEATURES OPSİYONEL ÖZELLİKLER

MİDEA ISI POMPASI-HAVUZ /SPA SU ISITMA

Üniversal Giriþli Proses indikatörü

CHARACTERISTICS UNITY KENAR KONTROL CİHAZI (UEC01) KULLANIM KLAVUZU GENEL ÖZELLİKLER UNITY EDGE CONTROL DEVICE (UEC01) USER S MANUAL

GENEL BİLGİLER - GENERAL INFORMATION

TRİSTÖR MODÜL SÜRÜCÜ KARTI (7 SEG) KULLANIM KILAVUZU AKE-PE-TMS-001

M03 SRG 100. Sliding Systems Decorative Ventilation Door Hardware. Teknik Detaylar / Installation Guide.

Su ile soğutma sistemleri

KULLANMA KLAVUZU / USER'S GUIDE GTİP/HS Code:

SOĞUTMALI İNKÜBATÖR MODEL: H90S / H130S / H200S KULLANMA KILAVUZU

Yüksek darbe dayanımına sahip alüminyum enjeksiyon gövde High impact resistance provided by aluminium injection

VERSİYON A1.0. Özellik. Teknik Özellikler. Ekran İşaretlerini Anlamı. Cihazın Ayarlanması KAR-MAK SOĞUTMA

Pano Soğutmasında Devrim Yaptık... SPLIT TYPE CABINET AIR CONDITIONERS DIŞ ÜNİTELİ PANO KLİMALARI

SK 2400 On-Off Seviye Kontrolörü Montaj ve Kullanım Kitapçığı

Bebek Hamağı Kullanım Kılavuzu Baby Hammock User Guide

ELDAŞ Elektrik Elektronik Sanayi ve Tic.A.Ş.

GD 910 Operating Instructions

- bilgi@cagsanmerdiven.com.tr

24kV,630A Outdoor Switch Disconnector with Arc Quenching Chamber (ELBI) IEC IEC IEC 60129

GENİŞLEYEN GÜVENLİK KAPISI EXPANDING SAFETY GATE

SOĞUTMALI ÇALKALAMALI İNKÜBATÖR MODEL: H200SH KULLANMA KILAVUZU

BANKET ARABASI (ELEKTRİKLİ)

Opto Recess S. 70mm. 140mm

Sorun Yıkamaksa Çözüm

MONTAJ İŞLETME ve BAKIM KILAVUZU DİKDÖRTGEN KANAL TİPİ FANLAR

SP-Multimetreler Kullanım Kılavuzu

AKE MİKSER KONTROL KARTI ÜÇ HIZLI KULLANIM KILAVUZU

TEOS plus+ TEOS SERİSİ MONTAJ TALİMATI TEOS SERIE ASSEMBLING INSTRUCTION TEOS MODÜLER PANO MONTAJ TALİMATI TEOS ENCLOSURE ASSEMBLING INSTRUCTION

Asansör Kliması Montaj ve Kullanım Kılavuzu

HİDROLİK TAMPON MONTAJ VE KULLANIM KILAVUZU

MONTAJ İŞLETME ve BAKIM KILAVUZU ÇATI TİPİ FANLAR

NEO NEO SERİSİ MONTAJ TALİMATI NEO SERIE ASSEMBLING INSTRUCTION NEO MODÜLER PANO MONTAJ TALİMATI NEO ENCLOSURE ASSEMBLING INSTRUCTION NEO SERIES

ODA SOĞUTUCULARI UNIT AIR COOLERS. ısıtma ve soğutmanın ritmini biz belirliyoruz!.. we give the rhythm in terms of heating and cooling!..

Özellikler Standart Ürün Paket İçeriği Kurulum... 2

HIGH SPEED PRECISION SPINDLES YÜKSEK DEVİRLİ HASSAS İŞ MİLLERİ.

Arýza Giderme. Troubleshooting

ALP 44 L ÖLÇÜ VE KONTROL CİHAZI KULLANMA KILAVUZU

MINIBOX MINIBOX

KURULUM ve KULLANIM KILAVUZU

BANQUET TROLLEYS BANKET ARABALARI

GMC FCU-097 ÜRÜNLERİ ÖZELLİKLERİ:

BSL4 MALZEME VE TEKNİK ÖZELLİKLER DOSYASI

Çelik Kuyumculuk Kalıp Makine San. Ve Tic. Ltd. Şti.

REZİSTANS ÖZELLİKLERİ CHARACTERISTICS OF HEATERS CHARACTERISTICS OF FANS FAN ÖZELLİKLERİ

Tek Setli, Tek Çýkýþlý, Çok Fonksiyonlu Hýz Ölçer

AÇELYA AZALEA. Motorlu Servis Reyonu / Plug-In Serve Over Counters

AKE MİKSER KONTROL KARTI TEK HIZLI KULLANIM KILAVUZU

D-Link DSL 500G için ayarları

MODEL OP-LP1 MODEL OP-LP2

PRODUCTS. Surgical Instruments. Sterile Container Systems. Sterilization Wire-Steel Sheet Baskets. Silicone Mat and Accessories

Montaj ve Kullanım Kılavuzu Installation and Operating Instructions

BAYMAK IDEE kw 60 GJ. 37 kwh 17 GJ 94 % 86 % 46 db(a) hayır

FWB 201 FWD 202 FWV 203 FWT 204 FWM 205 FWL 206 FWC 207 FWF 208

AUTOMATIC POWER FACTOR CONTROLLER REAKTİF GÜÇ KONTROL RÖLESİ. Shreem Capacitors Pvt. Ltd. AFB Enerji Mühendislik Ltd. Şti.

NUMUNE KURUTMA FIRINI MODEL: A KULLANMA KILAVUZU

BKV 5400 Yüzey Blöf Kontrol Vanası Montaj ve Kullanım Kitapçığı

Projenizin gizli değeri. Hidden value of your project MOTOR VE POMPA MOTORS AND PUMPS

2 Tanıtım. Biz kimiz?

T150 MOTORLU SWG BAKIM VE KULLANIM KILAVUZU

RU1000 Kepenk Güç Kaynağı. Uzaktan Kumandalı Kepenk Güç Kaynağı KULLANIM KILAVUZU

Delta Pulse 3 Montaj ve Çalıstırma Kılavuzu.

Teknik Özellikler Technical Specifications

Manuel Yüklemeli Katı Yakıt Kazanı Kontrol Cihazı Fonksiyonel Açıklama

M SFT. Sürgü Sistemleri Kapı Donanımları Dekoratif Menfezler. Sliding Systems Decorative Ventilation Door Hardware

KULLANIM KILAVUZU

BANT KAYNAK MAKİNESİ BENT WELDING MACHINE KULLANMA KLAVUZU USER'S GUIDE. GTİP/HS Code:

ABSOLUTE ROTARY ENCODER

REDÜKTÖRLÜ GİYOTİN MAKASLAR DIRECT GEAR MOTORISED GUILLOTINES

HRV-IP. Tavan Tipi Isı Pompalı Isı Geri Kazanım Cihazı

Kusursuz bir onarım ancak cihazın tamamı gerekli olduğu her zaman zarar verilmeden sökülebiliyorsa mümkündür.

1.CİHAZ ÖLÇÜLERİ 2.CİHAZ BAĞLANTI ŞEMASI

ÇALKALAMALI SU BANYOSU MODEL: H11900 H11960 KULLANMA KILAVUZU

1.CİHAZ ÖLÇÜLERİ 2.CİHAZ BAĞLANTI ŞEMASI

1.CİHAZ ÖLÇÜLERİ 2.CİHAZ BAĞLANTI ŞEMASI

GENEL SO UTMA MAK NALARI SAN. VE T C. LTD.fiT. Hava So utmal Kondenserler Air Cooled Condensers

PATATES SOYMA MAKİNASI KONTROL KARTI (2,4 TFT DOKUNMATİK DİKEY TİP) KULLANIM KILAVUZU AKE-PSM-301

Saha Montajlı Sıcaklık Transmitter TTF300

TEK KADEMELİ GAZ BRÜLÖRLERİ SINGLE STAGE GAS BURNERS

Ortam havası ile soğutma sistemleri

PID KONTROLLÜ SU BANYOLARI HALKALI KAPAKLI MODELLER: J11695K J11330K - J11540K KULLANMA KILAVUZU

1.CİHAZ ÖLÇÜLERİ 1.RÖLE KARTI VE ÖLÇÜLERİ

1.CİHAZ ÖLÇÜLERİ 2.RÖLE KARTI ÖLÇÜLERİ

ENDÜSTRİYEL CHILLER INDUSTRIAL CHILLER

KTC. Qn = Qh / (Fh x Fm x Fr x Ft x Fa) Qh = Qc x Fk. KTC 1/2/3/4 Serisi Kondenserler / KTC 1/2/3/4 Series Condensers

AYDIN KOMPRESÖR. En Yüksek Performans. En Zor Şartlarda. %100 YERLİ İMALAT

Transkript:

Uludağ Klima Soğutma Sist.Ltd.Şti. Tel: (224) 243 70 71 Faks: (224) 243 88 96 www.uludagklima.com info@uludagklima.com Pano Kliması Enclosure Cabinet Cooler Schaltschrank - Kühlgeräte Montaj ve Kullanım Kılavuzu Device Work Schedule Einbau-und Benutzerhandbuch www.uludagklima.com info@uludagklima.com 444 3 780 Tel : +90 224 243 70 71 Faks: +90 224 243 88 96

İNDEX 1.GÜVENLİK (Sayfa 2) 1.1 Kullanım sırasında dikkat edilecek hususlar 1.2. İşletmecinin sorumlulukları 1.3 Personelin sorumlulukları 1.4 Güvenlik önlemlerine ilişkin diğer uyarılar 1.5 Önemli uyarı! 1.6 Amaca uygun kullanma 2.GARANTİ ŞARTLARI VE SORUMLULUKLAR (Sayfa 3) 3.NAKLİYE VE DEPOLAMA (Sayfa 3) 3.1 Kabul sırasında alıcı tarafından yapılacak kontroller 3.2 Nakliye zararlarının haber verilmesi ve belgelenmesi 3.3 Ambalaj 3.4. Araca yükleme 3.5 Bekleme ve depolama 4.ÜRÜN TANITIMI (Sayfa 4) 5.MONTAJ (Sayfa 5) 5.1 Montaj işlemleri 5.2 Ürün detayları 6.BAKIM (Sayfa 9) 6.1 Kondanser bakımı 6.2 Evoperatör bakımı 6.3 Yetkili servis/satıcıya haber verilmeden önce yapılacaklar 7.DİJİTAL AYARLAMASI (Sayfa 12) 7.1 Pano içindeki istenilen sıcaklık değerinin (SET1) değiştirilmesi 7.2 Parametrelerin değiştirilmesi 7.3 Dijitalin fabrika ayarlarına geri döndürülmesi 8.ELEKTRİK DEVRE ŞEMASI (Sayfa 14) *** ENGLISH (Page 15)

1. GÜVENLİK 1.1. Kullanım Sırasında Dikkat Edilecek Hususlar Güvenli ve arızasız olarak kullanımı için ön koşul, temel güvenlik talimatları konusunda bilgi sahibi olmaktır. Bu kullanım kılavuzu, ürünün güvenli şekilde kullanımı için en önemli hususları içermektedir. Bu kullanım kılavuzu içerisinde yer alan uyarılar, özellikle çalışan elemanlar ve kullanılan cihazlar açısından önemlidir. Dikkate alınmalıdır. Bunun dışında kullanım alanı için gerekli olan tüm kullanım ve kaza önleme talimat ve uyarılarına da dikkat edilmelidir. 1.2. İşletmecinin Sorumlulukları İşletmeci, pano klimalarının bağlı olduğu cihazlarda sadece aşağıda tanımı yapılan kişilerin çalışmasına izin vermelidir. * İş güvenliği ve kaza talimatlarını bilen yetkili kişilerin, * Bu kılavuzdaki güvenlik kurallarını okumuş kişilerin, UYARI: Düzenli aralıklarla personelin güvenlik bilinciyle çalışıp çalışmadığını kontrol ediniz. 1.3. Personelin Sorumlulukları Bu pano klimaların bağlı olduğu cihazlarda çalışmakta olan kimseler çalışmaya başlamadan önce aşağıdakileri yapmakla yükümlüdür. * İş güvenliği ve kaza önlem konusundaki talimatlara dikkat etmek, * Kullanım kılavuzundaki güvenlik ve uyarıları okumak. 1.4. Güvenlik Önlemlerine İlişkin Diğer Uyarılar Kullanım kılavuzunun sürekli olarak cihazın yanında bulunması şarttır. Kullanım kılavuzuna ek olarak cihazın bulunduğu alandaki diğer kaza ve tehlikelere karşı uyarıcı talimatlar olmalıdır. 1.5. Önemli Uyarı! Montaj Ve Kullanımda TS 7936 EN 60335-2-40 Güvenlik Kuralları * Klima cihazı çalışırken pano kapaklarının kapalı olmasına dikkat ediniz. Pano kapaklarını açacağınız zaman klima cihazının enerjisini kapatınız. * Korozyona sebebiyet veren ve patlayıcı (tozlu, buharlı veya gazlı) ortamlarda kullanılması tehlikeli olabilir, uygulama alanları kontrol edilmelidir. * Cihazda çalışma, bakım, onarım ancak klima cihazı bağlı bulunduğu panodan sökülüp ayrıldıktan sonra yapılmalıdır. * Cihaz üzerindeki fanlara, çalışırken kesinlikle müdahale edilmemelidir. * Fan çalışırken elle müdahalede bulunmak, parmak, el kopmalarına büyük yaralanmalara sebebiyet verebilir. 1.6. Amaca Uygun Kullanma Pano klimaları, sadece kullanım kılavuzunda belirtilen montaj şartlarında, uygun montajı yapılmalı ve belirtilen güvenlik kurallarına kullanılmalıdır. Pano klimalarının kullanım amacı, cihaz elektrik ve kumanda panolarının belirtilen sıcaklık aralığında kalmasını sağlamaktır. Pano klimaları amaç dışı kullanımlarda ve talimata uygun olmayan montajlarda ULUDAĞ KLİMA ISITMA SOĞUTMA LİMİTED ŞİRKETİ sorumlu tutulamaz. Amaca uygun kullanımda, kullanım kılavuzundaki uyarıların tümüne dikkat etmek ve bakım talimatlarının aynen uygulanmasıyla gerçekleşir. Dikkat! Pano klimaları bağlanacağı panoya uygun kapasite seçilmeli ve sonradan bir değişiklik yapılmamalıdır. Yapılacak değişikliklerde Uludağ klima ısıtma soğutma sanayi ticaret limited şirketi garantisi ortadan kalkar.

2. GARANTİ ŞARTLARI VE SORUMLULUKLAR Uludağ Klima Isıtma Soğutma Sanayi Ticaret Limited Şirketi genel satış ve şartları geçerlidir. Kişisel veya mal zararlarındaki garanti ve sorumluluk konularının aşağıdaki sebeplerden bir veya birden fazlası oluştuğunda geçerliliğini yitirir. Pano klimasının talimata uygun montaj edilmemesi halinde, Pano klimasının talimata uygun bakım ve onarımı yapılmadığında, Kullanım kılavuzunda belirtilen taşıma, depolama ve devreye alma, kullanım ve bakımına ilişkin uyarılar dikkate alınmadığında, Pano klimalarında üretici bilgisi dışında değişiklikler yapıldığında, Bakım ve onarımlar talimatlara aykırı yapıldığında, İlgisiz kişilerin sebep olduğu arıza ve olumsuzluklarda. 3. NAKLİYE VE DEPOLAMA Kabin klimaları karton ya da ahşap koliler içerisinde taşınmalıdır. Her karton koli içerisinde 1 adet kabin kliması bulunmalıdır. Koli üzerindeki uyarı işaretlerine (üst taraf, kırılacak eşya, ıslanmaktan koruyun vb.) dikkat edilmeli ve uyulmalıdır. 3.1. Kabul Sırasında Alıcı Tarafından Yapılacak Kontroller Nakledilen pano klimaları ve bunlara ait paketler listelere göre tam olmasının kontrolü, zarar görme ve dikkat çekici noktaların kontrolleri yapılması gerekir. 3.2. Nakliye Zararlarının Haber Verilmesi Ve Belgelenmesi Nakliye esnasında herhangi bir zararın oluşup oluşmadığından emin olunuz. Zarar tespit edildi ise hemen çizim, fotoğraf ve yapılacak yazılı açıklamalar ile belgelendiriniz. Bu belgeleri Uludağ Klima Isıtma Soğutma Sanayi Ticaret Limited Şirketi ne en kısa sürede iletiniz. 3.3. Ambalaj Paketleme malzemeleri çevre dostudur, tekrar kullanılabilir. Özel nakliye şartları ve sigorta müşteriye aittir. 3.4. Araca Yükleme Kabin klimaları, ambalaj üzerindeki uyarı ikazlarına dikkat edilerek zarar görmeyecek şekilde olmalıdır. Nakliye esnasında nem, ıslaklık, çarpma ve devrilmelere karşı tedbir alınarak yerleştirilmelidir. 3.5. Bekletme Depolama Bekletilme bölgesi uygun olmayan şartlara sahipse (nem, ısı ve hasar görebilecek ortam)ortam uygun hale getirilerek depolanmalıdır veya uygun bölge seçilmelidir.

4.ÜRÜN TANITIMI PANOLARDA ISIDAN KAYNAKLANAN SORUNLARIN ÇÖZÜMÜ Yaz ayları yaklaştıkça elektrik panolarının sıcaklıkları yükselir (yaklaşık 45 60 C). Bu artışa bağlı olarak üretimi aksatacak duruşların meydana gelmesi kaçınılmazdır. Bu beklenen ve günler öncesinden GELIYORUM diye tehlike karşısında alınacak önlem Pano Klima cihazlarımızdır. Uludağ Pano Klima Cihazlarıyla; üretimdeki duruşlara SON verin..!!

5.MONTAJ: 5.1 Montaj Şablonunu pano üzerinde uygun yere yapıştırınız. 5.2 Şablonda gösterilen kesitleri, dekopaj vs. kesici bir aletle boşaltın. *Klimanın panoda sabitlenebilmesi için, gösterilen delikleri matkap ile deliniz. (8mm)

5.3 Ambalajda gönderilen montaj vidaları ile klimanın kabine montajını gerçekleştirin. 5.4. Enerji besleme kablosu ile cihaza enerji verin.

5.2.ÜRÜN DETAYI : ÖLÇÜLER / DIMENSION X Y Z A B C D E F G H Svk500 320 228 470 188 164 130 45 115 230 380 188 Svk1000 350 207 695 270 165 193 60 223 27 550 200 Svk2000 400 237 850 250 250 259 70 243 300 650 250 Svk3000 400 258 950 314 210 357 74 272 330 770 254 Svk4000 500 285 1004 224 224 410 90 228 T 2000 400 700 408 230 60 380 60 100 250 613 230 T 4000 444 780 450 250 75 437 75 100 300 700 250

Tecnic Data Svk-500 Svk-1000 Svk-2000 Svk-3000 T-2000 T-4000 Cooling capacity L35 L35 450 W 1000 W 1700 W 2700 W 1700 W 3700 W Type of refrigerant R 134a R 134a R 134a R 134a R 134a R134a Amount of refrigerant 290 gr 410 gr 550 gr 630 gr 630 gr 1150 g Thermostat setting 34 C 34 C 34 C 34 C 34 C 34 C Hysteresis 4K 4 K 4 K 4 K 4 K 4 K External circuit 540 m³/h 540 m³/h 945 m³/h 1175 m3/h 1005 m3/h 1800 m³/h Organize Sanayi Bölgesi Internal circuit 290 m³/h 540 m³/h 945 m³/h 945 m³/h 945 m³/h 1175 m³/h Demirciler Sitesi Rated frequency 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz D Blok No:2 Standard power supply 198 V-252 V 198 V 252 V 198 V 252 V 198 V 252 V Nilüfer 198 V 252 / BURSA V / 380 TURKEY V Running current 1.6 A 3.2 A 4.2 A 6.5 A 4.2 A 6.8 A Starting current 5.2 A 16.2A 17.2A 21.2A Telefon: 17.2A +90 (224)23 35,770 A 71 Weight 19 kg 35 kg 40 kg 45 kg Faks: 40 kg +90 (224) 243 62 kg 88 96 Height x Width x Depth mm 470*320*215 670*350*207 850*400*230 950*400*255 410*700*400 445*787*450 Ambient air temperature +15 C 55 C Corrosion protection (cover) Stainless / Paslanmaz Çelik Orientation Wall Mount Top Mount System of protection IP 54 Fans EbmPapst Compressor DANFOSS DANFOSS DANFOSS DANFOSS DANFOSS EMBRACO

6.BAKIM : Cihazınızın 15 günlük periyotlarda kondanser, 6 aylık dönemlerde evaporatör bakımı yapılması gerekmektedir. Ortamın kirlilik durumuna bağlı olarak bu dönemleri siz belirlemelisiniz. 6.1.Kondanser Bakımı: 1-Cihazın enerjisini kapatıp ön kapağını açınız. 2-Kondansere yapışmış olan yağ, kir, toz v.s basınçlı hava ile temizleyiniz. (Kirli kondanser ısı transferinin yetersiz olmasına, cihazın kısa sürede arızalanmasına ve yüksek enerji sarfiyatına sebep olur. Temizlenmiyor ise yağ çözücü solvent kullanınız.) 3-Fan kanatlarında bulunan kirleri temizleyiniz. 4-Drenaj hortumunu kontrol ediniz. Kırılma tıkanma varsa gideriniz. (Aksi durumda pano içerisine yoğuşma suyu sıçrama ihtimali vardır) 5-Elektrik bağlantı kablolarını kontrol ediniz. (Aşınma,sürtünme, yerinden çıkma, cihazın arızalanmasına, kısa devre oluşmasına sebep olur) 6-Cihazın termostat ayarlarını kontrol ediniz. Satıcı firmanın önerdiği ısı değerlerinde olmasına dikkat ediniz. (34 C - 38 C) (Pano içini ihtiyacın altında soğutmak gereksiz enerji sarfiyatına ve cihazın çabuk yıpranmasına sebep olur) 7- Cihazın kapağının kapandığına emin olduktan sonra enerjisini veriniz. (Kapağın açık olması cihazın verimli çalışmamasına ve iş kazasına sebep olabilir) Not: Cihazınız Er2 ya da Ch2 hata mesajı verdiğinde kondanser bakımını yapınız.

6.2.Evaporatör Bakımı: 1- Cihazın içerde bulunan fanın etrafındaki 8 adet cıvatayı söküp FAN Menfezini çıkarınız. 2- Fan motorunun altında olan evaparatör peteğinin üzerine yapışmış olan yağ, kir, toz v.s basınçlı hava ile temizleyiniz. Evaporatör tavasına su döküp suyu takip ederek drenaj hattının kontrol ediniz. 3- Fan kanatlarında bulunan kirleri temizleyiniz. 4- Elektrik bağlantı kablolarını kontrol ediniz. 5 İlk işlemde sökülen fan menfezini takıp cihaza enerji veriniz. 6- Cihazın termostat ayarlarını kontrol ediniz. Satıcı firmanın önerdiği ısı değerlerinde olmasına dikkat ediniz. (34 C - 38 C) Not: Cihazınız Er3 ya da Ch3 hata mesajı verdiğinde EVAPORATÖR bakımını yapınız.

6.3. Yetkili Servis / Satıcıya Haber Vermeden Önce Yapılacak Kontroller : Yetkili servise haber vermeden önce: * Cihaz çalışmıyor? Elektrik bağlantılarını kontrol ediniz. * Cihaza elektrik geliyor fakat çalışmıyor? Elektrik bağlantılarını kontrol ediniz termostat değerlerini kontrol ediniz. (çalışma sıcaklık değerleri ortam ısısından aşağıda olması gerekmektedir) * Cihaz çalışıyor fakat soğuk hava üflemiyor / yeterince üflemiyor? Evaparatör fanının çalışıp çalışmadığını kontrol ediniz. Fan çalışıyorsa ; evaperatör tıkanmıştır. Evaparatörü yukarıda anlatıldığı gibi temizleyin * Cihaz çalışıyor fakat kısa süre sonra devre dışı oluyor? Termostat değerlerini kontrol ediniz. (çalışma sıcaklık değerleri ortam ısısından aşağıda olması gerekmektedir) Kondanser fanının çalıştığından emin olunuz. Kondanserin temiz olduğuna emin olunuz değil ise yukarıda kondanseri temizleme talimatına bakınız. * Cihaz çalışıyor fakat hiç devreden çıkmıyor? Cihazın termostat ayarlarını kontrol ediniz satıcı firmanın önerdiği ısı değerlerinde olmasına dikkat ediniz (34 C 38 C) Panoya dışarıdan ortam havası girişi var mı, kontrol ediniz panonun kapakları açık kalmış olabilir Önemli uyarı!!! Klima cihazı çalışırken pano kapaklarının kapalı olmasına özen gösteriniz. Pano kapaklarını açacağınız zaman klima cihazınızın enerjisini kapatınız. Aksi durumda, ortamdaki tozlar evaparatörü tıkayacaktır..

7. DİJİTAL AYARLANASI : Dijitalin programlanması ile ilgili detaylı bilgi ek olarak gönderilen dökümanda mevcuttur. Özetle:

7.1. Parametrelerin değiştirilebilmesi için menüye giriş ve parametrelerdeki olması gereken fabrika değerleri : PARAMETRELERİN FABRİKA AYARLARI Cihaz Çalışma Modunda İken, Aşağı ve Yukarı Ok tuşlarına 3sn.boyunca basılırsa 1.MENÜ PARAMETRELERİ ne girilir 1.MENÜ PARAMETRELERİ DEFAULT SL1 Set1 Değeri Münimum Parametresi 26 SH1 Set1 Değeri Maximum Parametresi 99 HS1 kompresör Çıkışı için Histerisiz Parametresi 0.1 ASA Asansör Uygulaması için Bekleme 0 Of1 Kabin Sensör Ofset Parametresi 0 Of2 Kondanser Sensör Ofset Parametresi 0 Of3 Evaporatör Sensör Ofset Parametresi 0 Cihaz Çalışma Modunda İken, Reset (R) ve SET tuşlarına 3sn.boyunca basılırsa 2.MENÜ PARAMETRELERİ ne girilir 2.MENÜ PARAMETRELERİ DEFAULT SEn Sensörlerin Aktif/İptal Parametresi 1 HCS Isıtma/Soğutma Fonksiyon Seçimi 0 Pnt Nokta Pozisyonu Parametresi 1 ınt Dijital Giriş Tipi Seçimi 0 ıno Dijital Giriş Filtre Süresi 0 ıpo Dijital Giriş Polarizasyon 0 CSd Start-Stop Gecikme Parametresi 0 Con Sensör Arızası ON süresi 0 CoF Sensör Arızası OFF süresi 0 Alo Düşük Alarm Arızası SET 0.0 Ahı Yüksek Alarm Arızası SET 99.9 Cnd Kondaser Sensör Değeri ölçülen EuP Evaporatör Sensör Değeri ölçülen

7.3. Dijitalin Fabrika Ayarlarına Geri Döndürülmesi : AŞAĞI OK ve Reset (R) Basılı tutulur iken, cihaza enerji verilirse fabrika parametre değerleri geri yüklenir. 8.ELEKTRİK DEVRE ŞEMASI :

SOLUTION OF PROBLEMS CAUSED BY HEAT Summer months approaches, temperature rises in enclosures (approximately 45-60 C) with this increase, unscheduled downtime is inevitable. Against to this expected and said "l'm COMING" danger, precautions to be taken is our enclosure cabinet coolers. Uludag enclosure cabinet cooler devices; put an end to breaks in production..! Uludag enclosure cabinet cooler devices; put an end to breaks in production..! During the guarantee period, what may come per unit the unlimited scope of our device is under warranty.when you send the device to our address (without specifying any excuse) failure shall be removed within the same business day. if the device can not be resolved within 3 business days then new product will be sent to the user. Delivery time is one day in all our products. All sheet metal parts of our products is stainless steel. You can get the smooth automation solutions with using our products equipped with the components known as class A in the world. Danfoss compressors and EbmPapst fans are used on our products.

1.ASSEMBLY : 1.1 Fully wired ready for connection, including drilling template, and assembly parts. 1.2 Cut out the sections and drill according to the template.

1.3 ASSEMBLY WITH SCREWS Screw tapped pins into the blind nuts on the rear of the unit. 1.4. ENERGIZE THE DEVICE WITH THE SENT CABLE (220 V)

2.Product Details : DIMENSION X Y Z A B C D E F G H Svk500 320 228 470 188 164 130 45 115 230 380 188 Svk1000 350 207 695 270 165 193 60 223 27 550 200 Svk2000 400 237 850 250 250 259 70 243 300 650 250 Svk3000 400 258 950 314 210 357 74 272 330 770 254 Svk4000 500 285 1004 224 224 410 90 228 T 2000 400 700 408 230 60 380 60 100 250 613 230 T 4000 444 780 450 250 75 437 75 100 300 700 250

Tecnic Data Svk-500 Svk-1000 Svk-2000 Svk-3000 T-2000 T-4000 Cooling capacity L35 L35 450 W 1000 W 1700 W 2700 W 1700 W 3700 W Type of refrigerant R 134a R 134a R 134a R 134a R 134a R134a Amount of refrigerant 290 gr 410 gr 550 gr 630 gr 630 gr 1150 g Thermostat setting 34 C 34 C 34 C 34 C 34 C 34 C Hysteresis 4K 4 K 4 K 4 K 4 K 4 K External circuit 540 m³/h 540 m³/h 945 m³/h 1175 m3/h 1005 m3/h 1800 m³/h Organize Sanayi Bölgesi Internal circuit 290 m³/h 540 m³/h 945 m³/h 945 m³/h 945 m³/h 1175 m³/h Demirciler Sitesi Rated frequency 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz D Blok No:2 Standard power supply 198 V-252 V 198 V 252 V 198 V 252 V 198 V 252 V Nilüfer 198 V 252 / BURSA V / 380 TURKEY V Running current 1.6 A 3.2 A 4.2 A 6.5 A 4.2 A 6.8 A Starting current 5.2 A 16.2A 17.2A 21.2A Telefon: 17.2A +90 (224)23 35,770 A 71 Weight 19 kg 35 kg 40 kg 45 kg Faks: 40 kg +90 (224) 243 62 kg 88 96 Height x Width x Depth mm 470*320*215 670*350*207 850*400*230 950*400*255 410*700*400 445*787*450 Ambient air temperature +15 C 55 C Corrosion protection (cover) Stainless / Paslanmaz Çelik Orientation Wall Mount Top Mount System of protection IP 54 Fans EbmPapst Compressor DANFOSS DANFOSS DANFOSS DANFOSS DANFOSS EMBRACO

3.MAINTENANCE : 15-day period of your device in the condenser, evaporator care has to be made in annual periods. Depending on the situation of environment pollution, you must specify the period. (May extend or decrease) 3.1.CONDENSER CARE 1. Be sure the energy of the device turned off before open the front door. 2. Clean the condenser with preassured air from oil,dust etc.(dirt on the condenser may couse insufficient heat transfere, getting failed rapidly and high energy consumption. Solvent can be used if contamination is heavy.) 3. Clean the dirt on fan blades. (Dirt causes to fan balance and to fail in a short time). 4. Check the drain hose. Remedy the defects if there are breaks or obstructions. (Otherwise condensation water may splash into the panel.) 5. Check the electrical connection cable. (Abrasion or dislocation may lead short circuit and fail of the device.) 6. Check the thermostat settings for the device. Be sure the values are adjusted to the recomendation of the seller. (34 C - 38 C) 7. Turn on the energy after the lid of the device is closed. (Operating the device while lid is open may cause injuries or malfunction.)

3.2.Evaporator CARE: 1. Turn off the energy and unscrew the 8 pcs bolts inside of the device and remove the fan cover. 2. Clean the oil,dust etc. with preassured air from the evaporator cellular which under the fan engine. To check the dreinage line s efficiency, pour some water into the evaporator pan and wach for obstructions. 3. Clean the dirt on fan blades. 4. Check the electrical connection cable. 5. Replace the fan cover back and turn the energy on. 6. Check the thermostat settings for the device. Be sure the values are adjusted to the recomendation of the seller. (34 C - 38 C)

3.3. Before the notify service : The device does not work? Check electrical connections. Device is receiving power but not working? Check the thermostat value. (Set value should be below ambient temperature) Device is working. but it does not blow cold air / not enough to blow? Check that the fan is running clogged evaporator. Clean the evaporator, as described above. Shortly after the device works, but is disabled? Check the thermostat value. (Operating temperature range from ambient temperature must be below) Make sure the condenser fan is running. Make sure the condenser is clean If not, see above instructions for cleaning condenser (the high pressure circuit protection may be on. Device is working. but it does not come from the circuit? Check the thermostat settings for the device. In the heat value of the firm suggests that you pay attention to (34 C - 38 C). Ambient air from outside is input to the clipboard, you check. The door panels may be left open. Important Notice!!! The device is running, the cover must be closed. When you open the lid, turn off power. Otherwise, the environment and the dust will block evaporator

4. The DIGITAL SETTING ADVANCED PROGRAMMING FOR DIGITAL DATA sent as attachments of the document.

factory values of parameters 4.3. back to the factory settings for digital: By holding the up down buttons pressed for 3 seconds when the device is on, then enter in menu 1 parameters. 1.MENU PARAMETERS DEFAULT SL1 Set1 value minimum parameter 26 SH1 Set1 value maximum parameter 99 HS1 Hysteresis parameter for compressor 0.1 ASA Waiting mode for elevator application 0 Of1 Off-set parameter for cabin sensor 0 Of2 Off-set parameter for condenser sensor 0 Of3 Off-set parameter for evaporater sensor 0 By holding the reset (R) and SET buttons pressed for 3 seconds, then enter in menu parameters. 2.MENU PARAMETERS DEFAULT SEn Sensors Active-Cancel parameters 1 HCS Selecting heating/cooling functions 0 Pnt Point position parameter 1 ınt Digital Input Type Selection 0 ıno Digital Input Filter Selection 0 ıpo Digital input polarization 0 CSd Start-Stop Delay Parameters 0 Con Sensor fault ON time 0 CoF Sensor fault OFF time 0 Alo Low alarm fault setting 0.0 Ahı High alarm fault setting 99.9 Cnd Condenser sensor value measured EuP Evaporater sensor value measured

ULUDAĞ PANO KLİMA SİSTEMLERİ OSB, Minareliçavuş Mh. Türen Sk. No:7 NİLÜFER / BURSA / TURKIYE TEL: +90 224 243 70 71 FAX: +90 224 243 88 96 www.uludagklima.com info@uludagklima.com