Emt Fittings/EMT Boru Aksesuarlar EMT Compression Connectors/Die Cast Compression type connectors are used to secure and terminate steel EMT conduit to knock-outs in concrete-tight box, dry or damp location applications. Concrete-Tight S kmal Zamak Rakor : EMT borular buat, armatür, pano ve benzeri yerlerde sonland rmakta kullan l r. UL Listed: E20498 CSA Certified:LR792 UL 4B CSA C22.2 No. 8 NEMA FB- NEC Article 348 840 0840-2 /2".9 0.98 0.38-0/00 0 84 084-4 3/4".29.22 0.40-2/20 3 842 0842- ".48.2 0. - 0/200 40 843 0843-8 /4".70.84 0.6-2/00 40 844 0844- /2".86 2.4 0.6-0/40 22 84 084-2 2" 2.3 2.4 0.76 - /20 6 846* 0846-9 2 /2" 2.62 3.28.0-2 3 847* 0847-6 3" 2.70 3.94.04-2 6 848* 0848-3 3 /2" 2.80 4.0.08-0 8 849* 0849-0 4" 2.80 4.98.08-6 2 *EMT, IMC & RIGID w/insulated Throat 80 080-6 /2".9 0.98 0.38-0/00 0 8 08-3 3/4".29.22 0.40-2/20 3 82 082-0 ".48.2 0. - 0/200 40 83 083-7 /4".70.84 0.6-2/00 40 84 084-4 /2".86 2.4 0.6-0/40 22 8 08-2" 2.3 2.8 0.76 - /20 6 86* 086-8 2 /2" 2.62 3.28.0-2 3 87* 087-3" 2.70 3.94.04-2 6 88* 088-2 3 /2" 2.80 4.0.08-0 8 89* 089-9 4" 2.80 4.98.08-6 2 * EMT, IMC & RIGID / Raintight 80-RT 0873- /2".9 0.98 0.38-0/00 60 8-RT 0874-2 3/4".29.22 0.40-2/20 43 82-RT 087-9 ".48.2 0. - 0/00 2 EMT Compression Couplings/Die Cast Compression type couplings are used to join lengths of steel EMT conduit for concrete-tight, dry or damp location applications. Concrete-Tight S kmal Zamak Muf: EMT borular n birbirine eklenmesinde kullan l r. UL Listed: E20498 CSA Certified:LR792 830 0803-8 /2".70 0.98 0.73-0/00 60 83 083-3/4".78.22 0.94-2/20 48 832 0832-2 ".8.2.8-0/00 28 833 0833-9 /4" 2.2.84.2-0/40 7.6 834 0834-6 /2" 2.42 2.4.76-0/40 28.2 83 083-8 2" 2.47 2.8 2.23 - /20 8. 836* 0836-2 /2" 3.27 3.28 2.90-2 6 837* 0837-2 3" 3.3 3.94 3.3-2 2 838* 0838-9 3 /2" 3.0 4.0 4.00-0 22 839* 0839-6 4" 3.6 4.98 4.0-6 * EMT, IMC & RIGID / Raintight 830-RT 0870-4 /2".9 0.98 0.38-0/00 3 83-RT 087-6 3/4".29.22 0.40-2/20 2 832-RT 0872-8 ".48.2 0. - 0/200 28 UL 4B CSA C22.2 No. 8 NEMA FB- NEC Article 348 B 0
Emt Fittings/EMT Boru Aksesuarlar EMT Set Screw Connectors/Die Cast Set screw type connectors are used to secure and terminate steel EMT conduit to knock-outs in concrete-tight box or dry location applications. Concrete-Tight when taped -4"-4" Double Set Screw Vidal Zamak Rakor: EMT borular buat, armatür, pano ve benzeri yerlerde sonland rmakta kullan l r. UL Listed: E20498 CSA Certified:LR792 UL 4B CSA C22.2 No. 8 NEMA FB- NEC Article 348 800 0800- /2".4 0.38 0.72-0/00 3 80 080-8 3/4".40 0.46 0.94-2/20 2 802 0802- "..00.8-0/200 30 803 0803-2 /4".96 0.62.3-2/00 32 804 0804-9 /2" 2.20 0.70.77-0/40 6 80 080-6 2" 2.0 0.7 2.23 - /20 806* 7020-0 2 /2" 3.00.00 2.89-2 0 807* 7020-4 3" 3.38 3.93 3.4-2 2 808* 0808-7 3 /2" 3.6 4.4 4.06-0 3 809* 70220-3 4" 3.7.02 4.3-6 9 *EMT, IMC & RIGID w/ Insulated Throat 80 080-0 /2".4 0.38 0.72-0/00 3 8 08-7 3/4".40 0.46 0.94-2/20 2 82 082-4 "..00.8-0/200 30 83 083- /4".96 0.62.3-2/00 32 84 084-8 /2" 2.20 0.70.77-0/40 6 8 08-2" 2.0 0.7 2.23 - /20 86* 086-2 2 /2" 3.00.00 2.89-2 0 87* 087-9 3" 3.38 3.93 3.4-2 2 88* 088-6 3 /2" 3.6 4.4 4.06-0 3 89* 089-3 4" 3.7.02 4.3-6 9 *EMT, IMC & RIGID EMT Set Screw Couplings/Die Cast Set screw type couplings are used to join lengths of steel EMT conduit for concrete-tight or dry location applications. Concrete-Tight when taped -4"-4" Double Set Screw 820 0820-9 /2".0 0.93 0.73-0/00 3 82 082-6 3/4".87.4 0.9-2/20 2 822 0822-3 " 2.00.4.9-0/200 28 823 0823-0 /4" 2.0.83.3-2/00 32 824 0824-7 -/2" 2.87 2.06.77-0/40 24 82 082-4 2" 3.44 2.3 2.23 - /20 826* 7030-7 2-/2" 4.00 3.30 2.90-2 9 827* 7030-3" 4.49 3.94 3.4-2 2 828* 0828-3 /2" 4.92 4.4 4.0-0 2 829* 70320-0 4".23 4.96 4. - 6 0 *EMT, IMC & RIGID Vidal Zamak Muf: EMT borular birbirine ba lamakta kullan l r. UL Listed: E20498 CSA Certified:LR792 UL 4B CSA C22.2 No. 8 NEMA FB- NEC Article 348 B 02
Emt Fittings/EMT Boru Aksesuarlar EMT Compression Connectors/Steel Catalog UPC No Trade Case Case Number 0-87 Size Qty Wt. Compression type connectors are used to secure and terminate steel EMT conduit to knock-outs in concrete-tight box, dry or damp location applications. Concrete-Tight S kmal Çelik Rakor: EMT borular buat, armatür, pano ve benzeri yerlerde sonland rmakta kullan l r. Steel E20498 E4 E84480 UL 4B CSA C22.2 No. 8 NEMA FB- NEC Article 348 LR792 940 94 942 943 944 94 946* 947* 948* 949* * EMT & RIGID 0940-6 094-3 0942-0 0943-7 0944-4 094-0946-8 0947-0948-2 0949-9 /2" 3/4" " -/4" -/2" 2" 2-/2" 3" 3-/2" 4" 0/20 2/2 /7 20 0 8 Catalog UPC No Trade Case Case Number 0-87 Size Qty Wt. w/insulated Throat 90 090-9 09-2 92 092-9 93 093-6 94 094-3 9 09-0 96* 096-7 97* 097-4 98* 098-99* 099-8 * EMT & RIGID /2" 3/4" " -/4" -/2" 2" 2-/2" 3" 3-/2" 4" 0/20 2/2 /7 20 0 8 30 2 9 0 3 0 3 3 3 8 30 2 9 0 3 0 3 3 3 8 EMT Compression Couplings/Steel Catalog UPC No Trade Case Case Number 0-87 Size Qty Wt. Compression type couplings are used to join lengths of steel EMT conduit for concrete-tight, dry or damp location applications. Concrete-Tight S kmal Çelik Muf: EMT borular birbirine ba lamakta kullan l r. Steel 930 93 932 933 934 93 936* 937* 938* 939* * EMT & RIGID 0930-7 093-4 0932-0933-8 0934-093-2 0936-9 0937-6 0938-3 0939-0 /2" 3/4" " -/4" -/2" 2" 2-/2" 3" 3-/2" 4" 0/20 2/2 /7 20 0 8 32 20 23 2 4 2 9 6 8 2 E20498 E4 E84480 LR792 UL 4B CSA C22.2 No. 8 NEMA FB- NEC Article 348 B 03
Emt Fittings/EMT Boru Aksesuarlar EMT Set Screw Connectors/Steel Catalog UPC No Trade Case Case Number 0-87 Size Qty Wt. Set screw type connectors are used to secure and terminate steel EMT conduit to knock-outs in concrete-tight box or dry location applications. Concrete-Tight when taped -4"-4" Double Set Screw Vidal Çelik Rakor : EMT borular buat, armatür, pano ve benzeri yerlerde sonland rmakta kullan l r. Steel E20498 E4 E84480 UL 4B CSA C22.2 No. 8 NEMA FB- NEC Article 348 LR792 900 90 902 903 904 90 906* 907* 908* 909* *EMT & RIGID 0900-0 090-7 0902-4 0903-0904-8 090-0906-2 0907-0908-6 0909-3 /2" 3/4" " -/4" -/2" 2" 2-/2" 3" 3-/2" 4" 0/20 2/2 20/00 /2 0 0 8 Catalog UPC No Trade Case Case Number 0-87 Size Qty Wt. w/insulated Throat 90 090-9 9 09-6 92 092-3 93 093-0 94 094-7 9 09-4 96* 096-97* 097-8 98* 098-99* 099-2 *EMT & RIGID /2" 3/4" " -/4" -/2" 2" 2-/2" 3" 3-/2" 4" 0/20 2/2 20/00 /2 0 0 8 2 4 23 0 6 8 9 3 4 2 4 23 0 6 8 9 3 4 EMT Set Screw Couplings/Steel Catalog UPC No Trade Case Case Number 0-87 Size Qty Wt. Set screw type couplings are used to join lengths of steel EMT conduit for concrete-tight or dry location applications. Concrete-Tight when taped -4"-4" Double Set Screw Vidal Çelik Ek Muf : EMT borular eklemekte kullan l r. 920 92 922 923 924 92 926* 927* 928* 929* * EMT & RIGID 0920-8 092-0922-2 0923-9 0924-6 092-3 0926-0 0927-7 0928-4 0929- /2" 3/4" " -/4" -/2" 2" 2-/2" 3" 3-/2" 4" 0/20 2/2 0/00 /2 0 0 8 2 8 24 4 9 3 3 4 Steel E20498 E4 E84480 LR792 UL 4B CSA C22.2 No. 8 NEMA FB- NEC Article 348 B 04
Emt Fittings/EMT Boru Aksesuarlar Raintight Steel Compression Connectors Compression type connectors are used to secure and terminate steel EMT conduit to knock-outs in raintight applications. Raintight S kmal Çelik Rakor (S v S zd rmaz) : EMT borular buat, armatür, pano ve benzeri yerlerde sonland rmakta kullan l r. Steel E200730 UL 4B NEMA FB- Catalog UPC No Trade Case Case Number 0-87 Size Qty Wt. 9600 960 9602 9603 9604 960 9606 9607 9608 9609 09600-0960-2 09602-9 09603-6 09604-3 0960-0 09606-7 09607-4 09608-09609-8 /2" 3/4" " -/4" -/2" 2" 2-/2" 3" 3-/2" 4" 2/20 2/20 0/00 2 20 2 6 3 26. 42. 22.7 0.2 0 0 2.2 4. 4.4 0.3 Catalog UPC No Trade Case Case Number 0-87 Size Qty Wt. w/insulated Throat 960 0960-4 96 096-962 0962-8 963 0963-964 0964-2 96 096-9 966 0966-6 967 0967-3 968 0968-0 969 0969-7 /2" 3/4" " -/4" -/2" 2" 2-/2" 3" 3-/2" 4" 2/20 2/20 0/00 2 20 2 6 3 26. 42. 22.7 0.2 0 0 2.2 4. 4.4 0.3 Raintight Steel Compression Couplings Compression type couplings are used to join lengths of steel EMT conduit for raintight applications Raintight Catalog UPC No Trade Case Case Number 0-87 Size Qty Wt. 9620 962 9622 9623 9624 962 9626 9627 9628 9629 09620-3 0962-0 09622-7 09623-4 09624-0962-8 09626-09627-2 09628-9 09629-6 /2" 3/4" " -/4" -/2" 2" 2-/2" 3" 3-/2" 4" 2/20 2/20 0/200 2 20 2 6 3 3 3.3 28 2..9.8 24.7.8..8 S kmal Çelik Muf (S v S zd rmaz) : EMT borular birbirine eklemekte kullan l r. Steel E200730 UL 4B NEMA FB- B 0 90 Conduit Elbow To join lengths of steel EMT for concretetight or dry location applications EMT 90º Dönüfl: 90º lik EMT boru dönüfllerinde kullan l r. 4º ve 30º dönüfllerde mevcuttur. Features: Concretetight Pre-set/pre-staked set screws Combination head set screws OFFSET Figure STRAIGHT Figure 2 Catalog Trade Trade Minimum Figure. Figuro 2. Number Size Designator UL Radius Offset straight End in. mm in. mm in. mm in. mm EMT-ELL00 /2 6 4 02 6/4 9 /2 38 EMT-ELL07 3/4 2 4 /2 4 7/6 89 /2 38 EMT-ELL00 27 3/4 46 9/4 23 7/8 48 EMT-ELL2 /4 3 7 /4 84 0/2 267 2 EMT-ELL0 /2 4 8 /4 20 2/8 32 2 EMT-ELL200 2 3 9 /2 24 4/4 368 2 EMT-ELL20 2/2 63 0 /2 267 87/8 479 3 76 EMT-ELL300 3 78 3 330 20 08 3/8 79 EMT-ELL30 3/2 9 38 233/4 603 3/4 83 EMT-ELL400 4 03 6 406 267/8 983 33/8 86 90 boru dönüfllerinde kullan l r 4º ve 30º Material/Finish: Steel/Zinc Plated UL Listed: CSA Certified:
Emt Fittings/EMT Boru Aksesuarlar 90 EMT Connectors 90 connectors are used to terminate steel EMT conduit to an unthreaded box or enclosure in dry or damp locations where a 90 bend is required. Compression Type Concrete -Tight Rain-Tight 8203 08203-9 /2".3 0.98 0. - 2/20 37. 8204 08204-6 3/4".47 0.42 0.2-20/200 4.0 S kmal Tip 90º Zamak Rakor (S v S zd rmaz) : EMT borular n pano, buat, kutu gibi girifllerde 90º ile sonland r lmas nda kullan l r. UL Listed: E4 CSA Certified:LR792 UL 4B CSA C22.2 No. 8 NEMA FB- NEC Article 348 90 EMT Connectors Number 0-387 Size A B C Unit Qty/Qty Wt. 838 838-3 /2".43.9 0.48-20/200 29.6 839 839-0 3/4".47.42 0.4-20/200 4.6 90 connectors are used to terminate steel EMT conduit to an unthreaded box or enclosure in dry locations where a 90 bend is required. Set Screw Type Vidal Tip 90º Zamak Rakor EMT borular n pano, buat, kutu gibi girifllerde 90º ile sonland r lmas nda kullan l r. UL Listed: E4 CSA Certified:LR792 UL 4B CSA C22.2 No. 8 NEMA FB- NEC Article 348 EMT To Box Offset Connectors 8300 08300- /2" 2.09 0.92 0.4-0/00 0.6 830 0830-2 3/4" 3.0.2 0.46-0/00 8.3 Set screw type offset connectors are used to make a slight adjustment in terminating the end of a run of steel EMT conduit to an enclosure or box in dry locations. Set Screw Type Concrete-Tight when taped Vidal Kutu Ba lant Zamak Rakoru: EMT borular n pano, buat, kutu gibi girifllerde, borular n farkl seviyelerde birlefltirilmesinde kullan l r. UL Listed: E20498 CSA Certified:LR792 UL 4B CSA C22.2 No. 8 NEMA FB- NEC Article 348 EMT To Box Offset Connectors Number 0-387 Size A B C Unit Qty/Qty Wt. 8308 08308- /2".87 0.98 0.40-0/00 27.9 8309 08309-8 3/4" 2.63.22 0.46-0/00 22.2 Compression type offset connectors are used to make a slight adjustment in terminating the end of a run of steel EMT Conduit to an enclosure or box in dry or damp locations. Compression Type Concrete -Tight S kmal Kutu Ba lant Zamak Rakoru: EMT borular n pano, buat, kutu gibi girifllerde, borular n farkl seviyelerde birlefltirilmesinde kullan l r. UL Listed: E20498 CSA Certified:LR792 UL 4B CSA C22.2 No. 8 NEMA FB- NEC Article 348 B 06
Emt Fittings/EMT Boru Aksesuarlar EMT To EMT Pull Elbows Pull elbows are used to facilitate pulling conductors through a 90 bend in a run of steel EMT Conduit. The removable cover gives ample access so that wire pulling can be achieved without any obstruction. Set Screw Type Removable Aluminum Cover Kapakl 90º Zamak Dönüfl: EMT borular n 90º dönüflünde kullan l r, vidal kapa sayesinde kabloya kolayca müdahale edilebilmesini sa lar. 8340 08340- /2".3.02 0.96-0/00 9.4 834 0834-8 3/4".37.28.8 - /0.0 8342 08342- ".9..2-0 6. 8343 08343-2 /4" 2.32.92.88-4.7 w/ Gasket 8340-G 084-6 /2".3.02 0.96-0/00 20. 834-G 0846-3 3/4".37.28.8 - /0 4.3 8342-G 0837-9 ".9..2-0 6. 8343-G 0838-6 /4" 2.32.92.88-4.8 UL 4B, CSA C22.2 No. 8 NEMA FB-, NEC Article 348 UL Listed: E4 CSA Certified:LR792 EMT To Box Pull Elbows Pull elbows are used to facilitate pulling conductors through a 90 bend in a run of steel EMT Conduit. The removable cover gives ample access so that wire pulling can be achieved without any obstruction. Set Screw Type Removable Aluminum Cover Kapakl zoleli 90º Zamak Dönüfl: EMT borular n 90º dönüflünde kullan l r, vidal kapa sayesinde kabloya kolayca müdahale edilebilmesini sa lar. Inside Corner Pull Elbows 8330 08330-2 /2".3.02 0.96-0/00 20. 833 0833-9 3/4".37.28.7 - /0 6.7 w/ Gasket 8330-G 08400-2 /2".3.02 0.96-0/00 2.6 833-G 0840-9 3/4".37.28.7 - /0.9 UL Listed: E4 CSA Certified:LR792 UL 4B CSA C22.2 No. 8 NEMA FB- NEC Article 348 82 082-2 /2".80 0.93 0.72 0 0/00 20.9 826 0826-9 3/4" 2.00.3 0.94 /0 3.8 Inside corner pull elbows are used to facilitate pulling conductors through a 90 bend in a run of steel EMT conduit where it is essential to make tight turns within limited available space. Set Screw Type Concrete-Tight when taped UL Listed: E4 CSA Certified:LR792 Kapakl 90º Zamak Dönüfl: EMT borular n s k fl k alanlarda 90º dönüflünde kullan l r, yandan aç labilir olmas sayesinde kabloya kolayca müdahale edilebilmesini sa lar. UL 4B CSA C22.2 No. 8 NEMA FB- NEC Article 348 EMT Nail Strap Nail straps are used to secure steel EMT Conduit to wooden structure members. Can be used in place of one or two hole straps. 9377 09377-6 /2" 2.00 0.30-00/000 7.3 9378 09378-3 3/4" 2.2 0.46-00/000 22.4 9379 09379-0 " 2.2 0.8-00/000 2.7 Döküm T rnakl Krofle: EMT borular n ahflap yüzeylere sabitlenmesinde kullan l r. Stamped Steel Finish: Zinc Plated B 07
Emt Fittings/EMT Boru Aksesuarlar EMT One Hole Straps One hole straps are used for providing support for steel EMT Conduit as required by the National Electrical Code. Click-On Type 930 0930-3 /2.6 0. 0.73-00/000 2.8 93 093-0 3/4.9 0.62 0.92-0/00 0.2 932 0932-7 2.30 0.7. - 0/00.3 933 0933-4 /4 2.87 0.88.49-2/20 22. 934 0934- /2 3.4.8-2/00.2 93 093-8 2 3.93.2 2.3 - /7 3.2 936 0936-2 /2 4.90.2 3.00-2.6 937 0937-2 3.3.2 3.60-2 2.7 938 0938-9 3 /2 6.8.2 4.3-2 7. 939 0939-6 4 6.68.2 4.63-2 6.0 Tek Delikli Sabitleme Kroflesi: Diflsiz EMT borular duvara sabitlemede kullan l r. Stamped Steel Finish: Zinc Plated UL 2239, CSA C22.2 No. 8 NEMA FB-, NEC Article 348 EMT Two Hole Straps Two hole straps are used for providing support for steel EMT Conduit where higher load bearing supports are desired as required by the National Electrical Code. Click-On Type Çift Delikli Sabitleme Kroflesi: Diflsiz EMT borular duvara sabitlemede kullan l r. 9330 09330- /2 2.2 0. 0.73-0/00 7.6 933 0933-8 3/4 2.70 0.63 0.93-0/00 4.2 9332 09332-3.0 0.68. - 0/200 7.6 9333 09333-2 /4 3.74 0.7.4-0. 9334 09334-9 /2 4.2 0.86.68-0 20.3 933 0933-6 2 4.76.00 2.20-0/0 6.4 9336 09336-3 2 /2.88.00 2.9-2. 9337 09337-0 3 6.0.00 3.3-2.9 9338 09338-7 3 /2 7.38.00 4.03-2 8.3 9339 09339-4 4 8.00.00 4.3-2 9. Stamped Steel Finish: Zinc Plated UL 2239, CSA C22.2 No. 8 NEMA FB-, NEC Article 348 Set Screw LR Conduit Bodies Conduit bodies are used to gain access to the interior of a raceway for wire pulling, inspection and maintenance where the raceway changes direction. Assembled with Cover and Gasket. Assembled with Cover and Gasket. Kondulet Buat : Boru tesisat nda dirsek olarak dönüfllerde, kablo çekmede tesisat içindeki kablolara ek yapmakta kullan l r. Vidal kapa sayesinde kablo ek yerlerine müdaheleyi kolaylaflt r r. Kapakla kodulet aras ndaki toz ve su geçirmez conta sayesinde IP-66 koruma s n f na uygundur. D00-CGV 600-6 /2 4.30.30 2.40-27 7 D0-CGV 606-8 3/4.00.0 2.60-7. D02-CGV 62-9.80.80 2.90-4 9 D03-CGV 68- /4 7.80 2.0 3.70-4. D04-CGV 624-2 /2 7.80 2.0 3.90-4 6 D0-CGV 630-3 2 9.80 3.20 4.70-2 4. 6-CG 77-2 /2 0.0 4.40.60 -.6 7-CG 776-8 3 0.0 4.0 6.00-6. 8-CG 777-3 /2.47.43 7.36-8. 9-CG 778-2 4.47.43 7.36-8.6 * "D" bodies are also threaded for rigid Aluminum Die-Cast Stamped Aluminum Cover UL Listed: E2488 CSA Certified:LR792 UL 4B CSA C22.2 No. 8 NEMA FB- NEC Article 348 B 08
Emt Fittings/EMT Boru Aksesuarlar Set Screw LL Conduit Bodies Conduit bodies are used to gain access to the interior of a raceway for wire pulling, inspection and maintenance where the raceway changes direction. Assembled with Cover and Gasket. Assembled with Cover and Gasket. Kondulet Buat : Boru tesisat nda dirsek olarak dönüfllerde, kablo çekmede tesisat içindeki kablolara ek yapmakta kullan l r. Vidal kapa sayesinde kablo ek yerlerine müdaheleyi kolaylaflt r r. Kapakla kodulet aras ndaki toz ve su geçirmez conta sayesinde IP-66 koruma s n f na uygundur. D200-CGV 636- /2" 4.30.30 2.40-27 7 D20-CGV 642-6 3/4".00.0 2.60-7. D202-CGV 648-8 ".80.80 2.90-4 9 D203-CGV 64-9 /4" 7.80 2.0 3.70-4. D204-CGV 660-0 /2" 7.80 2.0 3.90-4 6 D20-CGV 666-2 2" 9.80 3.20 4.70-2. 26-CG 779-9 2 /2" 0.0 4.40.60 -.6 27-CG 780-0 3" 0.0 4.0 6.00-6. 28-CG 78-2 3 /2".47.43 7.36-8. 29-CG 782-9 4".47.43 7.36-8.6 * "D" bodies are also threaded for rigid Aluminum Die-Cast UL Listed: E2488 Stamped Aluminum Cover CSA Certified:LR792 UL 4B CSA C22.2 No. 8 NEMA FB- NEC Article 348 Set Screw LB Conduit Bodies Conduit bodies are used to gain access to the interior of a raceway for wire pulling, inspection and maintenance where the raceway changes direction. Assembled with Cover and Gasket. Assembled with Cover and Gasket. Kondulet Buat : Boru tesisat nda dirsek olarak dönüfllerde, kablo çekmede tesisat içindeki kablolara ek yapmakta kullan l r. Vidal kapa sayesinde kablo ek yerlerine müdaheleyi kolaylaflt r r. Kapakla kodulet aras ndaki toz ve su geçirmez conta sayesinde IP-66 koruma s n f na uygundur. D600-CGV 708-9 /2" 4.30.30 2.40-30 7 D60-CGV 74-7 3/4".00.0 2.60-8 7. D602-CGV 720- ".80.80 2.90-6 9 D603-CGV 726-3 /4" 7.80 2.0 3.70-8. D604-CGV 732-4 /2" 7.80 2.0 3.90-8 6 D60-CGV 738-6 2" 9.80 3.20 4.70-2. 66-CG 877-0 2 /2" 0.0 4.40.60-4. 67-CG 774-2 3" 0.0 4.0 6.00-68-CG 787-4 3 /2".47.43 7.36-9. 69-CG 77-4".47.43 7.36-8. * "D" bodies are also threaded for rigid Aluminum Die-Cast UL Listed: E2488 Stamped Aluminum Cover CSA Certified:LR792 UL 4B CSA C22.2 No. 8 NEMA FB- NEC Article 348 Set Screw T Conduit Bodies Conduit bodies are used to gain access to the interior of a raceway for wire pulling, inspection and maintenance where the raceway changes direction. Assembled with Cover and Gasket. Assembled with Cover and Gasket. Kondulet T Buat : Boru tesisat nda T ba lant yapmakta, kablo çekmede tesisat içindeki kablolara ek yapmakta kullan l r. Vidal kapa sayesinde kablo ek yerlerine müdaheleyi kolaylaflt r r. Kapakla kodulet aras ndaki toz ve su geçirmez conta sayesinde IP-66 koruma s n f na uygundur. D700-CGV 744-7 /2" 4.30.30 2.40-6 D70-CGV 70-8 3/4".00.0 2.60-2. D702-CGV 76-0 ".80.80 2.90-4 9 D703-CGV 762- /4" 7.80 2.0 3.70-4 7. D704-CGV 768-3 /2" 7.80 2.0 3.90-4 6. D70-CGV 774-4 2" 9.80 3.20 4.70-2. 76-CG 788-2 /2" 0.0 4.40.60 -.6 77-CG 789-8 3" 0.0 4.0 6.00-6. 78-CG 790-4 3 /2".47.43 7.36-8. 79-CG 79-4".47.43 7.36-8.6 * "D" bodies are also threaded for rigid UL Listed: E2488 CSA Certified:LR792 UL 4B CSA C22.2 No. 8 NEMA FB- NEC Article 348 B 09
Emt Fittings/EMT Boru Aksesuarlar Set Screw C Conduit Bodies Conduit bodies are used to gain access to the interior of a raceway for wire pulling, inspection and maintenance where the raceway changes direction. Assembled with Cover and Gasket. Assembled with Cover and Gasket. Kondulet C Buat : Boru tesisat nda ba lant yapmakta, kablo çekmede tesisat içindeki kablolara ek yapmakta kullan l r. Vidal kapa sayesinde kablo ek yerlerine müdaheleyi kolaylaflt r r. Kapakla kodulet aras ndaki toz ve su geçirmez conta sayesinde IP-66 koruma s n f na uygundur. D300-CGV 672-3 /2" 4.30.30 2.40-24 6. D30-CGV 678-3/4".00.0 2.60-8 7. D302-CGV 684-6 ".80.80 2.90-4 9 D303-CGV 690-7 /4" 7.80 2.0 3.70-8 2 D304-CGV 696-9 /2" 7.80 2.0 3.90-8 D30-CGV 704-2" 9.80 3.20 4.70-2 36-CG 783-6 2 /2" 0.0 4.40.60-6. 37-CG 784-3 3" 0.0 4.0 6.00-7. 38-CG 78-0 3 /2".47.43 7.36-9 39-CG 786-7 4".47.43 7.36-2 * "D" bodies are also threaded for rigid Aluminum Die-Cast Stamped Aluminum Cover UL Listed: E2488 CSA Certified:LR792 UL 4B CSA C22.2 No. 8 NEMA FB- NEC Article 348 EMT To Flex Couplings Combination couplings are used to provide a transition from steel EMT conduit to Flexible Metal Conduit. Set Screw - Clamp Type Vidal EMT - Spiral Zamak Boru Geçifl Mufu : EMT borudan spiral çelik boruya geçifllerde kullan l r. 827 0827-6 /2"-3/8" 0.72 0.93.34-0/00 34.3 UL Listed: E20498 CSA Certified:LR792 UL 4B CSA C22.2 No. 8 NEMA FB- NEC Article 348 & 30 Combination couplings are used to provide a transition from steel EMT conduit to Flexible Metal Conduit. Set Screw - Squeeze Type Vidal EMT - Spiral Zamak Boru Geçifl Mufu : EMT borudan spiral çelik boruya geçifllerde kullan l r. 828 0828-3 /2"-/2" 0.93 0.94.62-2/20 2.9 829 0829-0 3/4"-3/4" 0.94 0.2.97-2/20 36 UL Listed: E20498 CSA Certified:LR792 B 0
Emt Fittings/EMT Boru Aksesuarlar EMT To Flex Couplings 820 0820-7 /2".40 0.92 0. - 0/00 40.9 82 082-4 3/4".2.2 0.20-2/20 30.8 Combination couplings are used to provide a transition from steel EMT Conduit to Flexible Metal Conduit. Compression - Screw in Type UL Listed: E4 CSA Certified:LR792 UL 4B CSA C22.2 No. 8 NEMA FB- NEC Articles 348 & 30 S kmal EMT - Spiral Zamak Boru Geçifl Mufu : EMT borudan spiral çelik boruya geçifllerde kullan l r. EMT Compression To Rigid Couplings Combination couplings are used to provide a transition from steel EMT conduit to Rigid Conduit. Compression - Threaded Type S kmal EMT - Rigid Boru Çelik Geçifl Mufu : EMT borudan rigid boruya geçifllerde kullan l r. IMC/Rigid taraf diflli, EMT taraf s kmal d r. 9460 09460- /2" /6" /8" 7/8" /6" 0/00 3.7 946 0946-2 3/4" 7/6" 3/8" /8" 3/4" 0/00 2. 9462 09462-9 " /2" /6" 3/8" 3/6" 0/00 33.3 Steel E20787 UL 4 NEMA FB- EMT Set Screw To Rigid Couplings 9463 09463-6 /2" " 2 3/8" 7/8" /6" 2/20 34.3 9464 09464-3 3/4" /4" 2 3/6" /8" /8" 0/00 2. 946 0946-0 " /2" 3" 3/8" 3/6" 0/00 33.3 Combination couplings are used to provide a transition from steel EMT Conduit to Rigid Conduit. Set Screw - Set Screw Type Steel E20787 UL 4B NEMA FB- E20787 Vidal EMT - Rigid Boru Çelik Geçifl Mufu : EMT borudan rigid boruya geçifllerde kullan l r. B
Emt Fittings/EMT Boru Aksesuarlar EMT/Rigid Clamp Backs Used to provide space between steel conduits and mounting surface. Döküm Boru Destek Aparat : Metal borular n kullan ld yüzeyle aras nda destek olarak kullan l r. Rijidli i sa lar. Malleable iron Finish: Zinc Plated CSA File No. LR792 Catalog UPC No Trade Ctn/Case Case Number 0-387 Size Qty/Qty Wt. 900 0900-8 /2" 2/20 27.7 90 090-3/4" 2/20 29.2 902 0902-2 " 2/2 20.4 903 0903-9 /4" 20/00 22.3 904 0904-6 /2" 0/00 2.6 90 090-3 2" /0 30.9 906 0906-0 2 /2" 0 7.6 907 0907-7 3" 0 0. 908 0908-4 3 /2" 0.6 909 0909-4" 0 7. -Hole Straps For Rigid Conduit. Malleable. Catalog UPC No Trade Ctn/Case Case Number 0-387 Size Qty/Qty Wt. To support Steel Conduits. Döküm Boru Kroflesi : Metal borular n desteklenmesinde kullan l r. Malleable iron Finish: Zinc Plated CSA File No. LR792 90 0900-7 /2" 2/20 27.7 9 090-4 3/4" 2/20 29.2 92 0902- " 2/2 20.4 93 0903-0 /4" 20/00 22.3 94 0904- /2" 0/00 2.6 9 090-2 2" /0 30.9 96 0906-9 2 /2" 0 7.6 97 0907-6 3" 0 0. 98 0908-3 3 /2" 0.6 99 0909-0 4" 0 7. B 2
IMC - RMC Conduit Fittings / IMC - RMC Boru Aksesuarlar IMC Elbows 90 INTERMEDIATE METAL CONDUIT ELBOWS ALL DIMENSIONS PROVIDED ARE FOR DESCRIPTIVE PURPOSES ONLY Catalog Number Trade Size Offset Fig. Straight Fig. 2 Weight - Pounds Per 00 Per Ctn. Standard Carton To join lengths of steel IMC-RMC for concretetight or dry location applications IMC 90 Dönüfl : 90 lik IMC boru dönüfllerinde kullan l r. 4 ve 30 dönüfllerde mevcuttur. IMC-ELL00 IMC-ELL07 IMC-ELL00 IMC-ELL2 IMC-ELL0 IMC-ELL200 IMC-ELL20 IMC-ELL300 IMC-ELL30 IMC-ELL400 /2 3/4 /4 /2 2 2 /2 3 3 /2 4 Material/Finish: Steel/Zinc Plated 6 3/8 7 /8 8 7/8 /2 2 3/4 /4 9 /8 24 /2 2 /4 2 3/4 3/4 2 /4 2 3/8 2 /8 2 /8 4 4 3/8 7 3/4 6 3/4 /2 2 82 36 22 306 480 900 00 800 2000 UL Listed: E2233 CSA Certified: 26 4 34 4 46 48 40 2 40 00 0 0 2 20 0 0 3 2 2 For IMC & Threadless Rigid Conduit Catalog Number Trade Size (inches) Dimensions in Inches A B 820 Set-Screw Style To join lengths of steel IMC-RMC for concretetight or dry location applications Vidal Zamak Muf: IMC-RMC borular n birlefltirilmesinde kullan l r. 826 Material/Finish: Zinc Die Cast UL Listed: E20498 CSA Certified:LR792 820 82 822 823 824 82 826 827 828 829 /2 3/4 /4 /2 2 2/2 3 3/2 4.02.7.28.94 2.3 2.27.99 2.23 2.63 2.94 2.69 3.0 3.26 4.0 3.90 4. 4.46.00 4.97.26 Applicable Third Party UL Standard:4B CSA Standard:C22.2 No.8 NEMA : FB- Fed.Spec: W-F-480E Type 2, Class 2, Kind K Compression Style 836 Catalog Number Trade Size (inches) Dimensions in Inches A B To join lengths of steel IMC-RMC for concretetight or dry location applications S kmal Zamak Muf: IMC-RMC borular n birlefltirilmesinde kullan l r. Material/Finish: Zinc Die Cast UL Listed: E20498 CSA Certified:LR792 836 837 838 839 2 /2 3 3 /2 4 3.63 3.27 3.2 3.89 3.77 4.40 4.06 4.89 Applicable Third Party UL Standard:4B CSA Standard:C22.2 No.8 NEMA : FB- Fed.Spec: W-F-480E Type 2, Class 2, Kind K B 3
IMC - RMC Conduit Fittings / IMC - RMC Boru Aksesuarlar Type GL Catalog Number Trade Size (inches) Bonding Wedge Used with bushings to bond threaded rigid conduit and IMC to boxes, cabinets or other enclosures where locknut is exposed. Kilitleme Somunu : IMC-RMC Borular n ve rakorlar n buat, kutu, pano ve benzeri yerlere tak ld ktan sonra kilitlenip sabitlenmesini sa lar. Features: Threaded for rigid conduit and IMC Material/Finish: Steel / Zinc Plated UL Listed: E267 L-00-D L-200-D L-300-D L-300-D L-00-D L-600-D L-700-D L-800-D L-900-D L-000-D /2 3/4 /4 /2 2 2 /2 3 3 /2 4 Applicable Third Party UL Standard:4B NEMA : FB- Type RB Catalog Number Trade Size (inches) Aluminium Lenght Reducing Bushing Flush Type To reduce the trade size of a tapered entry on a conduit fitting. Kilitleme Somunu : IMC-RMC Borular n girifl ölçülerinin de ifltirilmesinde kullan l r. NOTE: For larger sizes use O-Z/Gedney Type RB Features: Threaded for rigid conduit and IMC Material/Finish: Steel / Zinc Plated UL Listed: E267 Applicable Third Party UL Standard:4B NEMA : FB- RB-32S RB-322S RB-323S RB-324S RB-32S RB-326S RB-327S RB-328S RB-329S RB-320S RB-33 RB-332 RB-333 RB-334 RB-33 RB-336 RB-337 RB-339 RB-340 RB-34 RB-342 RB-349 RB-30 RB-3 RB-3 RB-36 RB-37 3/4 - /2-3/4 - /2 - /4-/2 - /4-3/4 /4 - /2 - /4 /2 - /2-3/4 /2 - /2 2 - /2 2 - /4 2-2 - 3/4 2 - /2 2 /2-2 2 /2 - /2 2 /2-3 - /2 3-2 3-2 /2 3 /2-3 3 /2-2 /2 4-2 4-2 /2 4-3 4-3/2 RB-32A RB-322A RB-323A RB-324A RB-32A RB-326A RB-327A RB-328A RB-329A RB-330A RB-33A RB-332A RB-333A RB-334A RB-33A RB-336A RB-337A RB-339A RB-340A RB-34A RB-342A RB-349A RB-30A RB-3A RB-3A RB-36A RB-37A 23/32 23/32 23/32 3/6 3/6 3/6 3/6 3/6 3/6 3/6 7/8 7/8 7/8 7/8 7/8 /4 /4 /4 3/8 3/8 /2 /2 /2 /2 B 4
IMC / RMC to EMT Conduit Compression Couplings IMC / RMC EMT geçifl mufu: Diflli IMC / RMC borulardan diflsiz EMT borulara geçiflte kullan lan s kmal tip ba lant muflar d r. Features: * Threaded rigid and IMC to compression EMT * Concretetight * NPT female Hubs Material / Finish: Malleable Iron/Zinc Plated CONDUIT FITTINGS IMC - RMC Conduit Fittings / IMC - RMC Boru Aksesuarlar UL Listed: E267 CSA Certified: Catalog Number ETR-0 ETR-7 ETR-00 ETR-2 ETR-0 ETR-200 Trade Size (inches) /2 3/4 /4 /2 2 NÇ OLARAK ÖLÇÜLER UZUNLUK MAX. ÇAP 3/8 /8 /6 3/8 /2 3/4 7/8 2 3/8 7/8 2 2 /6 3 /2 Applicable Third Party UL Standard:4B NEMA : FB- For IMC & Threadless Rigid Conduit Set-Screw Coupling 806 Zamak Vidal Tip IMC - RMC Boru Rakoru: IMC-RMC borular n pano, buat, armatür ve benzeri yerlere ba lant s nda kullan l r. Material/Finish: Zinc Die Cast Catalog Number 806 807 808 809 Trade Size (inches) 2 /2 3 3 /2 4 Insulated Throat Catalog Dimensions in Inches Number A B C 86 87 88 89 3.0.07 3.27 3.3.60 3.9 3.6.03 4. 3.76. 4.97 Set-screw type connectors are used to secure and terminate steel or aluminum, EMT, rigid or IMC conduits to knockouts in concretetight or dry location applications. Concretetight when taped. UL Listed: E2067 CSA Certified:LR792 Applicable Third Party UL Standard: 4B CSA Standard: C22.2 No. 8 NEMA: FB- Fed. Spec: W-F-408E, Type 2, Class 2, Kind L, Style Compression Style Coupling Catalog Number Trade Size (inches) Insulated Throat Catalog Dimensions in Inches Number A B C 846 847 848 849 2 /2 3 3 /2 4 86 87 88 89 2.86 0.99 3.29 2.90.0 3.89 2.9.0 4.39 2.73.00 4.9 846 Compression type connectors are used to secure and terminate steel or aluminum, EMT, rigid or IMC conduits to knockouts in concretetight box, dry, or damp location applications. Concretetight. Material/Finish: Zinc Die Cast UL Listed: E20498 CSA Certified:LR792 Applicable Third Party UL Standard: 4B CSA Standard: C22.2 No. 8 NEMA: FB- Fed. Spec: W-F-408E, Type 2, Class 2, Kind L, Style Zamak S kmal Tip IMC - RMC Boru Rakoru: IMC-RMC borular n pano, buat, armatür ve benzeri yerlere ba lant s nda kullan l r. B
IMC - RMC Conduit Fittings / IMC - RMC Boru Aksesuarlar CONDUIT HUB Threaded Die Cast Zinc Catalog # Unit Standard Weight Lbs. Number Size Quantity Package Per 00 8490 3/8 2 20 2 849 /2 2 37 20 8492 3/4 2 20 32 8493 2 20 40 8494 /4 0 00 60 849 /2 0 00 70 8496 2 0 60 90 8497 2 /2 0 200 8498 3 2 30 20 8499 3 /2 2 2 300 800 4 2 2 30 80 8 600 802 6 8 800 * not supplied with insulator. Applications: Ideal for pharmaceutical, chemical and food processing, pulp/paper and nuclear industries. Resistant to a variety of chemicals, including acetic, citric and salt water. The O-ring is a special and has excellent chemical resistance. Hub is provided with a steel ground nut. Diflli Zamak Rakor: Ucu diflli borular n pano, kutu, buat girifllerinde sonland r lmas nda kullan l r. laç ve g da sanayiinde, ka t ve nükleer enerji tesislerinde kullan m için uygundur. Contas tuzlu su ve kimyasallara dayan kl d r. UL Listed: E20498 CSA Certified:LR792 CONDUIT GROUND HUB Threaded Die Cast Zinc Max. Copper Catalog # Unit Std. Weight Lbs. Grd.Wire Size Number Size Quantity Pkg. Per 00 CSA UL 8480 /2 2 32 20 #8 #8 848 3/4 2 22 30 #8 #8 8482 2 0 43 #8 #8 8483 /4 0 00 #8 #8 8484 /2 0 90 73 #6 #8 848 2 0 60 9 #4 #8 8486 2 /2 3 90 #2 #8 8487 3 2 26 263 /0 #6 8488 3 /2 2 2 300 2/0 #6 8499 4 2 2 30 2/0 #4 8490* 8 62 2/0 #2 849* 6 8 70 3/0 # * Not supplied with insulator. Applications: Ideal for pharmaceutical, chemical and food processing, pulp/paper and nuclear industries. Resistant to a variety of chemicals, including acetic, citric and salt water. The O-ring is a special and has excellent chemical resistance. Hub is provided with a steel ground nut. Diflli Zamak Rakor: Ucu diflli borular n pano, kutu, buat girifllerinde sonland r lmas nda kullan l r. laç ve g da sanayiinde, ka t ve nükleer enerji tesislerinde kullan m için uygundur. Contas tuzlu su ve kimyasallara dayan kl d r. UL Listed: E20498 CSA Certified:LR792 B 6
IMC - RMC Conduit Fittings / IMC - RMC Boru Aksesuarlar Compression Connectors Number 0-387 Size A B C Unit Qty/Qty Wt. Compression type connectors are used to secure and terminate threadless Rigid or IMC Conduits toa steel outlet box or metal enclosure. Concrete-Tight Steel 9280 09280-9 /2".3.3 0.0-20/200 23.4 928 0928-6 3/4".48.37 0.2-0/00 8. 9282 09282-3 ".3.69 0.64 - /0 8.0 9283 09283-0 /4".70 2.07 0.68 - /0 2.0 9284 09284-7 /2".96 2.28 0.72-2 3.0 928 0928-0 2" 2.07 2.79 0.72-2 0.2 Çelik S kmal Tip IMC - RMC Boru Rakoru: IMC-RMC borular n pano, buat, armatür ve benzeri yerlere ba lant s nda kullan l r. UL Listed: E4 CSA Certified:LR792 Compression Couplings Number 0-387 Size A B C Unit Qty/Qty Wt. Compression type couplings are used to join wo lengths of threadless Rigid or IMC Conduits. Concrete-Tight Steel 9290 09290-8 /2".64.3 0.8-0/00 30. 929 0929-3/4".80.37.07-0/00 2. 9292 09292-2 ".88.69.29 - /0 22.0 9293 09293-9 /4" 2.09 2.07.6 - /0 33.0 9294 09294-6 /2" 2.40 2.28.8-2 0.0 929 0929-3 2" 2.33 2.78 2.33-2 2.0 Çelik S kmal Tip IMC - RMC Ek Mufu: IMC-RMC borular n birbirlerine ba lant s nda kullan l r. UL Listed: E4 CSA Certified:LR792 Three Piece Couplings Used to connect two lenghts of threaded rigid conduit or IMC,when neither conduit can be turned. Cast of high strength malleable iron and zinc plated. Concrete-Tight Malleable Iron Number 0-387 Size A B C Unit Qty/Qty Wt. 920 0920-6 /2".64.3 0.8-0/00 20.4 92 092-3 3/4".80.37.07 - /0 2.9 922 0922-0 ".88.69.29 - /0 2.2 923 0923-7 /4" 2.09 2.07.6 - /2 22.3 924 0924-4 /2" 2.40 2.28.8 - /2 30.7 92 092-2" 2.33 2.78 2.33-20 36.8 926 0926-8 2 /2" 2.09 2.07.6-0 3.0 927 0927-3" 2.40 2.28.8-6.0 928 0928-2 3 /2" 2.33 2.78 2.33-29.8 929 0929-9 4" 2.33 2.78 2.33-2. Döküm S kmal Tip IMC - RMC Boru Rakoru: Diflli borular n hareket imkan bulunmad UL Listed: E4 CSA Certified:LR792 durumlarda borular birlefltirmek için kullan l r. B 7
IMC - RMC Conduit Fittings / IMC - RMC Boru Aksesuarlar Compression Rigid Connectors Number 0-387 Size A B C Qty/Qty Wt. Compression type connectors are used to secure and terminate threadless Rigid or IMC Conduits to a steel outlet box or metal enclosure. Concrete-Tight Malleable Iron Döküm S kmal Tip IMC - RMC Boru Rakoru: IMC-RMC borular n pano, buat girifllerinde kullan l r. UL Listed: E4 CSA Certified:LR792 960 0960-4 /2" /2" /2" /2" 2/20 0.8 96 096-3/4" /2" /2" /8" 2/20.8 962 0962-8 " /6" 9/6" 2" 2/00 33.7 963 0963- /4" 2" /6" 2 3/8" /0 26.0 964 0964-2 /2" 2 /6" /6" 2 /8" /0 32.7 96 096-0 2" 2 /4" 7/8" 3 /6" 20 2.4 966 0966-6 2 /2" 2 /6" /4" 3 3/4" 2. 967 0967-3 3" 3 /8" 3/8" 4 /4" 3 8.9 968 0968-0 3 /2" 3 /8" 3/8" 4 3/4" 2 7.7 969 0969-7 4" 3 3/8" /2" /6" 2 9.4 w/ insulated throat 970 0970-3 /2" 9/6" 9/6" /2" 2/20.3 97 097-0 3/4" 9/6" 9/6" /8" 2/20 6. 972 0972-7 " 3/4" /8" 2" 2/00 34. 973 0973-4 /4" 2" /6" 2 3/8" /0 26.3 974 0974- /2" 2 /8" 3/4" 2 /8" /0 33.0 97 097-8 2" 2 /6" 3/6" 3 /6" 20 22.7 976 0976-2 /2" 3" /6" 3 3/4" 2.3 977 0977-2 3" 3 /8" 7/6" 4 /4" 3 9.0 978 0978-0 3 /2" 3 3/6" /2" 4 3/4" 2 7.8 979 0979-6 4" 3 7/6" 9/6" /6" 2 9.4 Compression Rigid Coupling Compression type couplings are used to join two lengths of threadless Rigid or IMC Conduit. Concrete-Tight Malleable Iron Döküm S kmal Tip IMC - RMC Boru Mufu: IMC-RMC borular n birlefltirilmesinde kullan l r. UL Listed: E4 CSA Certified:LR792 Number 0-387 Size A B C Qty/Qty Wt. 980 0980-2 /2" 3/6" /2" /2" 0/00 30.0 98 098-0 3/4" 7/8" /2" /8" 0/00 32.0 982 0982-6 " 2 3/6" 9/6" 2" /0 2.9 983 0983-3 /4" 2 /8" 3/4" 2 3/8" /0 38.8 984 0984-0 /2" 2 /6" /6" 2 /8" 2.2 98 098-7 2" 3 /6" /6" 3 /6" 8.0 986 0986-4 2 /2" 4 /2" 2" 3 3/4" 3.8 987 0987-3" 4 /6" 2 /4" 4 /4" 3.8 988 0988-8 3 /2" " 2 /4" 4 3/4" 2 0.9 989 0989-4" /6" 2 7/6" /6" 2 2. Rigid to Rigid Pull Elbows Number 0-87 Size A B C Qty/Qty Wt. Pull elbows are used to facilitate pulling conductors through a 90 bend in a run of Rigid or IMC conduit. The removable cover gives ample access so that wire pulling can be achieved without any obstructions. Removable Aluminum Cover Kapakl Döküm 90º Dönüfl: IMC ve Rigid borular n 90 dönüflünde kullan l r, vidal kapa sayesinde kabloya kolayca müdahale edilebilmesini sa lar. W/O Gasket 834 0834-6 /2".3.02 0.96 0/00 8.8 8346 08346-3 3/4".37.28.26 /0 3.3 With Gasket 834-G 0839-3 /2".3.02 0.96 0/00 9.6 8346-G 08349-4 3/4".37.28.26 /0 3.7 8347-G 08347-0 ".9..2 2.6 8348-G 08348-7 /4" 2.32.92.88 20 8.8 UL Listed: E4 CSA Certified:LR792 Materials Neoprene Gasket Standards UL4B CSA C22.2 No. 8 NEMA FB- NEC Article 34 & 346 B 8
IMC - RMC Conduit Fittings / IMC - RMC Boru Aksesuarlar Rigid to Box Pull Elbows Number 0-87 Size A B C Qty/Qty Wt. Pull elbows are used to facilitate pulling conductors through a 90 bend in a run of Rigid or IMC conduit. The removable cover gives ample access so that wire pulling can be achieved without any obstructions. Removable Aluminum Cover Kapakl Döküm 90º Dönüfl: IMC ve Rigid borular n kutu ve panolara giriflinde 90 aç yla sabitlenmesini sa lar. Threaded Couplings Threaded couplings are used to join two lengths of threaded Rigid or IMC Conduit. Çelik Diflli Ek Mufu: IMC ve Rigid borular n birlefltirilmesinde kullan l r. W/O Gasket 833 0833-7 /2".3.02 0.96 0/00 8.3 8336 08336-4 3/4".37.28.8 /0 3.0 With Gasket 833-G 0840-7 /2".3.02 0.96 0/00 9.2 8336-G 0844-9 3/4".37.28.8 /0 3.3 UL Listed: E4 CSA Certified:LR792 Materials Neoprene Gasket Standards UL4B CSA C22.2 No. 8 NEMA FB- NEC Article 34 & 346 Number 0-87 Size A B Qty/Qty Wt. 9000 09000-3 /2" /8" " 00 2.6 900 0900-0 3/4" /8" /4" 0 8.0 9002 09002-7 " 2" /2" 30 8.3 9003 09003-4 /4" 2 /6" 7/8" 2 8.3 9004 09004- /2" 2 /8" 2 /8" 2.0 900 0900-0 2" 2 3/6" 2 /8" 20 4. 9006 09006-2 /2" 3 3/6" 3 3/6" 2 20.4 9007 09007-2 3" 3 /4" 3 3/6" 8 6.4 9008 09008-9 3 /2" 3 7/6" 4 /2" 4 0.6 9009 09009-6 4" 3 /2" 4 3/6" 4 3.9 UL Listed: E4 CSA Certified:LR792 Materials Steel Standards UL6 NEC Article 34 & 346 Box Spacers Number 0-87 Size A B C Qty/Qty Wt. 8202 08202-2 /2".2 0.40 0.62 0/00 38.6 Box spacers are used for providing a raceway between two steel outlet boxes or metal enclosures by connecting either side by side or back to back. Locknut not Included Zamak Kutu Ba lant Parças : Kutular n ve panolar n yanyana ya da arka arkaya ba lant s nda kullan l r. Materials UL Listed: E4 CSA Certified:LR792 Standards UL4B CSA C22.2 No. 8 NEMA FB- NEC Article 34 & 346 B 9
IMC - RMC Conduit Fittings / IMC - RMC Boru Aksesuarlar Conduit Locknuts Use Conduit locknuts are used for securing Rigid and IMC Conduits and other threaded connectors to a steel outlet box or metal enclosure. Çelik Kilitleme Somunu: Ucu diflli borular n ve rakorlar n buat, kutu, pano ve benzeri yerlere tak ld ktan sonra kilitlenip sabitlenmesini sa lar. Number 0-87 Size A B C Qty/Qty Wt. 3 7080-2 3/8.2 0.09.00 00/000. 32 7080-6 /2.37 0.0.2 00/000.4 33 708-3/4.7 0.2.6 00/000 6.2 34 70820-2.2 0.2.9 00/000 27.2 49 7082-0 /4 2.43 0.2 2.6 0/00 8.9 0 70830-4 /2 2.93 0.2 2.68 0/00 2.2 7083-9 2 3.6 0.7 3.2 40/400 29.3 2 70840-3 2 /2 4.8 0.7 3.9 30/300 44.4 3 7084-8 3.37 0.7.00 2/20 43.0 4 7080-2 3 /2 2.93 0.2 2.68 2/2 8.3 708-7 4 3.6 0.7 3.2 20/00 26.0 6 70860-4.8 0.7 3.9 0/30 23. 7 7086-6 6.37 0.7.00 0/30 26. Certification E4 LR792 Materials Steel Finish Zinc Plated Die-Cast Locknuts Conduit locknuts are used for securing Rigid and IMC Conduits and other threaded connectors to a steel outlet box or metal enclosure. Single Cast Thread Fully Reversible Creates a 360 Ground path UL Listed Stand Alone for Rigid Conduit Number 0-87 Size A B C Qty/Qty Wt. 840 0840-2 /2.0 0.4 0.98 00/000 2.0 84 084-9 3/4.3 0.4.24 00/000.0 842 0842-6.68 0.8. 00/000 22.0 843 0843-3 /4 2.06 0.2.88 0/00.0 844 0844-0 /2 2.38 0.2 2.2 20/200.0 84 084-7 2 2.92 0.2 2.7 2/20.0 846 0846-4 2 /2 3.2 0.29 3.24 0/00 6.0 Certification E4 LR792 Materials Standards UL4B CSA C22.2 No. 8 NEMA FB- NEC Article 34 & 346 Zamak Kilitleme Somunu: Ucu diflli borular n ve rakorlar n buat, kutu, pano ve benzeri yerlere tak ld ktan sonra kilitlenip sabitlenmesini sa lar. Plastic Insulating Bushings Number 0-87 Size A B C Qty/Qty Wt. Plastic insulating bushings are used on the end of Rigid and IMC Conduits and other threaded connectors to provide a smooth well rounded bearing surface to protect wires or cables. Rated 0ºC Flame Retardant zoleli Plastik Sonlama: Polypropilenden imal edilen plastik bushingler diflli borular n direk olarak yada rakor ile sonland r lmas nda kullan l r. Kablolar n zedelenmeden çekilmesini sa lar 0º ya kadar güvenle kullan labilir. zolesi sayesinde s zd rmazl k sa lar. 7 09003-4 /2.04 0.39 0.60 00/000 7.4 72 7070-9 3/4.27 0.4 0.78 00/000 9.7 73 707-4. 0.6.00 0/00 9.6 74 70720-8 /4.90 0.7.33 2/20 7.4 7 7072-3 /2 2.8 0.7.4 0.9 76 70730-7 2 3.7 0.73 2.36 0 2.3 77 7073-2 2 /2 3.7 0.73 2.36 2 2.0 78 70740-6 3 3.80 0.76 3.00 2 2.4 79 7074-3 /2 3.80 0.76 3.00 2 2.4 70 7070-4 3.80 0.76 3.00 2 2.4 Certification E4 LR792 Materials Thermoplastic Standards UL 4B CSA C22.2 No. 8 NEMA FB- B 20
IMC - RMC Conduit Fittings / IMC - RMC Boru Aksesuarlar Insulated Metallic Conduit Bushings Number 0-87 Size A B C Qty/Qty Wt. Insulated Metallic Conduit bushings are used on the end of Rigid and IMC Conduits and other threaded connectors to provide a smooth well rounded bearing surface to protect wires or cables. Thermoplastic Liner Rated 0 C Materials zoleli Zamak Sonlama: zoleli bushingler diflli borular n direk olarak yada rakor ile sonland r lmas nda kullan l r. Kablolar n zedelenmeden çekilmesini sa lar, 0º ya kadar güvenle kullan labilir. zolesi sayesinde s zd rmazl k sa lar. Certification E4 LR792 8260 08260-2 /2".28 0.42 0.4 00/000 29.9 826 0826-9 3/4".3 0.42 0.74 0/00 2.9 8262 08262-6 ".86 0. 0.96 2/20.4 8263 08263-3 /4" 2.6 0..27 2/20 24.7 8264 08264-0 /2" 2.63 0.2.49 0/00.9 826 0826-0 2" 2.72 0..9 0/00 4.9 8266 08266-4 2 /2" 3.22 0.83 2.32 0 4. 8267 08267-3" 3.8 0.83 2.92 0 4.8 8268 08268-8 3 /2" 3.22 0.83 2.32 0 4. 8269 08269-4" 3.8 0.83 2.92 0 4.8 w/insulated throat 820 0820-3 /2".28 0.42 0.4 00/000 29.9 82 082-0 3/4".3 0.42 0.74 0/00 2.9 822 0822-7 ".86 0. 0.96 2/20.4 823 0823-4 /4" 2.6 0..27 2/20 24.7 824 0824-0 /2" 2.63 0.2.49 0/00.9 82 082-0 2" 2.72 0..9 0/00 4.9 826 0826-2 /2" 3.22 0.83 2.32 0 4. 827 0827-2 3" 3.8 0.83 2.92 0 4.8 828 0828-9 3 /2" 3.22 0.83 2.32 0 4. 829 0829-6 4" 3.8 0.83 2.92 0 4.8 Standards UL 4B CSA C22.2 No. 8 NEMA FB- NEC Article 34 & 346 Bushings w/lug Catalog UPC No Trade Nominal Dimensions Pcs Ctn/Case Case Insulated metallic grounding bushings are used on the end of Rigid and IMC Conduits and other threaded connectors to provide a smooth well rounded bearing surface to protect wires or cables as well as providing a means to connect a grounding conductor. Nylon Liner Rated 0ºC 90ºC Dual Rated Feed Through Aluminum Lug Materials 8270 08270- /2".04 0.0 0.4-00/00 6.2 827 0827-8 3/4".28 0.0 0.74-0/20 2. 8272 08272- ".2 0.9 0.96-0/20 27.2 8273 08273-2 /4".87 0.6.27-2/2 3. 8274 08274-9 /2" 2.6 0.60.49-2/2 7.9 827 0827-6 2" 2.67 0.60.9-0/0 22.9 8276 08276-3 2 /2".2 0.9 0.96-0 27.2 8277 08277-0 3".87 0.6.27 - /2 3. 8278 08278-7 3 /2" 2.6 0.60.49-0 7.9 8279 08279-4 4" 2.67 0.60.9-0 22.9 Certification E88878 LR792 Standards UL 4B CSA C22.2 No. 8 NEMA FB- NEC Article 34 & 346 zoleli Zamak Sonlama: zoleli bushingler diflli borular n direk olarak yada rakor ile sonland r lmas nda kullan l r. Kablolar n zedelenmeden çekilmesini sa lar, 0º ya kadar güvenle kullan labilir. zolesi sayesinde s zd rmazl k sa lar. Vidal aparat sayesinde topraklaman n devam n sa lar. B 2
IMC - RMC Conduit Fittings / IMC - RMC Boru Aksesuarlar Conduit Nipples Conduit nipples are used to terminate threaded conduit to a knock-out, outlet box or metal enclosure where room is limited, or with a locknut to connect two outlet boxes or metal enclosures side by side or back to back. Materials Zamak Nipel : Döküm nipel diflli borular n kutu ya da panolarda sonland r lmas nda kullan l r. Kilitleme somunu ile kullan larak da kutular n ve metal panolar n yan veya arka yüzeylerinden birlefltirilmelerini sa lar. Catalog UPC No Trade Nominal Dimensions Pcs Ctn/Case Case 8220 08220-6 /2" 0.93 0.9 0.44-00/000 32.0 822 0822-3 3/4".9 0.7 0.0-0/00 29. 8222 08222-0 ".39 0.84 0.63-2/20 20.2 8223 08223-7 /4".7 0.87 0.63-2/20 30.3 8224 08224-4 /2" 2.3 0.90 0.63-2/00 2.0 822 0822-2" 2.6.0 0.72-0/40 9.4 8226 08226-8 2 /2" 3.28.43.04-0/40.3 8227 08227-3" 2.3 0.90 0.63-0/40 2.0 8228 08228-2 3 /2" 2.6.0 0.72-0/40 9.4 8229 08229-9 4" 3.28.43.04 - /20.3 w/insulated throat 8230 08230- /2" 0.93 0.9 0.44-00/000 32.0 823 0823-2 3/4".9 0.7 0.0-0/00 29. 8232 08232-9 ".39 0.84 0.63-2/20 20.2 8233 08233-6 /4".7 0.87 0.63-2/20 30.3 8234 08234-3 /2" 2.3 0.90 0.63-2/00 2.0 823 0823-0 2" 2.6.0 0.72-0/40 9.4 8236 08236-7 2 /2" 3.28.43.04-0/40.3 8237 08237-4 3" 2.3 0.90 0.63-0/40 2.0 8238 08238-3 /2" 2.6.0 0.72-0/40 9.4 8239 08239-8 4" 3.28.43.04 - /20.3 Certification Standards E88878 LR792 UL 4B CSA C22.2 No. 8 NEMA FB- NEC Article 34 & 346 Reducing Washers Reducing washers are used to reduce the size of a knock-out in a steel outlet box or metal enclosure. Two reducing washers are required for each knock-out Rust Proof Embossed for Self-Centering Materials Steel Çelik Redüksiyon : Çelik redüksiyonlar metal kutular ve panolarda bulunan ç k fl deliklerinde kullan l r. Her delik için iki adet redüksiyon gereklidir. Certification E2487 E8788 LR0469 Standards UL 4B CSA C22.2 No. 8 NEMA FB- NEC Article 34 & 346 Number 0-87 Size A B C Qty/Qty Wt. 9200 09200-7 3/4"- /2" 0.87.44 0.04 00/000.9 920 0920-4 "- /2" 0.87.7 0.04 20/200 2.9 9202 09202- "- 3/4"..7 0.04 00/000 2.9 9203 09203-8 /4"- /2" 0.87 2.8 0.04 0/00 6.9 9204 09204- /4"- 3/4". 2.8 0.04 00/000 6.9 920 0920-0 /4"- ".37 2.8 0.04 0/00.9 9206 09206-9 /2"- /2" 0.87 2.44 0.04 0/00 26.9 9207 09207-6 /2"- 3/4". 2.44 0.03 00/000 26.9 9208 09208-3 /2"- ".37 2.44 0.04 00/000 39.4 9209 09209-0 /2"- /4".72 2.44 0.04 00/000 39.4 920 0920-6 2"- /2" 0.87 3.00 0.03 2/20 2.9 92 092-6 2"- 3/4". 3.00 0.04 2/20 2.9 922 0922-0 2"- ".37 3.00 0.04 2/20 9.4 923 0923-7 2"- /4".72 3.00 0.04 2/20 9.4 924 0924-4 2"- /2".98 3.00 0.04 2/20 6.9 92 092-2 /2"- /2" 0.87 3.0 0.04 2/20 2.9 926 0926-8 2 /2"- 3/4". 3.0 0.04 2/20 2.9 927 0927-2 /2"- ".37 3.0 0.04 2/20 9.4 928 0928-0 2 /2"- /4".73 3.0 0.04 2/20 6.9 929 0929-9 2 /2"- /2".98 3.0 0.04 2/20 4.4 9220 09220-2 /2"- 2" 2.46 3.0 0.04 2/20.9 922 0922-0 3"- /2" 0.88 4.3 0.04 2.9 9222 09222-9 3"- 3/4". 4.3 0.04 2 2.9 9223 09223-6 3"- ".37 4.3 0.04 2 2.9 9224 09224-3 3"- /4".73 4.3 0.04 2 6.9 922 0922-0 3"- /2".98 4.3 0.04 2 6.9 9226 09226-7 3"- 2" 2.47 4.3 0.04 2.9 9227 09227-4 3"- 2 /2" 2.97 4.3 0.04 2 26.9 9228 09228-3 /2"- /2" 0.88 4.63 0.06 0 26.9 9229 09229-8 3 /2"- 3/4". 4.63 0.06 0 39.4 9230 09230-3 3 /2"- ".37 4.63 0.06 0 39.4 923 0923-9 3 /2" - /4".73 4.63 0.06 0 2.9 9232 09232-3 /2" - /2".98 4.63 0.06 0 2.9 9233 09233-3 /2" - 2" 2.47 4.63 0.06 0 9.4 9234 09234-4 3 /2" - 2 /2" 2.97 4.63 0.06 0 9.4 923 0923-0 3 /2" - 3" 3.9 4.63 0.06 0 6.9 9236 09236-6 4" - /2" 0.88. 0.06 0 2.9 9237 09237-2 4" - 3/4".. 0.06 0 2.9 9238 09238-8 4" - ".37. 0.06 0 9.4 9239 09239-4 4" - /4".73. 0.06 0 6.9 9240 09240-9 4" - /2".98. 0.06 0 4.4 924 0924-4" - 2" 2.47. 0.06 0.9 9242 09242-4" - 2 /2" 2.97. 0.06 0 6.9 9243 09243-7 4" - 3" 3.9. 0.06 0 4.4 9244 09244-0 4" - 3 /2" 4.3. 0.06 0.9 B 22
IMC - RMC Conduit Fittings / IMC - RMC Boru Aksesuarlar Reducing Bushings Reducing bushings are used to reduce the entry size of threaded conduit to allow joining conduits of two different sizes. Materials Offset Nipples Offset nipples are used to provide an offset connection between two outlet boxes or metal enclosures. 3/4" Axis Materials Service Entrance Ells Service entrance ells are used to gain access to the interior of a raceway for wire pulling, inspection and maintenance. Listed for Use in Wet Location Materials Die-Cast Aluminium Catalog UPC No Trade Nominal Dimensions Pcs Ctn/Case Case 846 0846-2 3/4 -/2 0.62 0.80 0.2-0/00 20.2 8462 08462-9 "-/2" 0.70.00 0.3-2/20 27.9 8463 08463-6 "-3/4" 0.70.00 0.3-2/20 32.7 Zamak Redüksiyon : ki farkl ölçüdeki diflli borular n birlefltirilmesinde kullan l r. Catalog UPC No Trade Nominal Dimensions Pcs Ctn/Case Case 8302 08302-8 /2" 2.42 0.94 0.42-0/00 0. 8303 08303-3/4" 2.40.8 0.42-0/00 3.2 8304 08304-2 " 2.72.40 0.60-0/00 2.2 830 0830-9 /4" 2.8.8 0.60 - /0 4.7 8306 08306-6 /2" 3.00 2.00 0.68 - /0 20.2 8307 08307-3 2" 3. 2.6 0.74-2/20.4 Zamak Kutu Ba lant Nipeli : ki farkl ç k fl kutusunun ya da panonun farkl seviyelerden birbirlerine ba lanmas n sa lar. Number 0-87 Size A B C Qty/Qty Wt. 00 700- /2" 3..9.4 38 8.0 0 700-3/4" 3.7.2.77 36 8.0 02 70-0 " 4.8.7.97 2 6.0 03 7020-4 /4".39 2.9 2.44 2. 04 702-9 /2" 6.0 2.36 2.44 0 0.0 0 7030-3 2" 6.6 2.87 2.93 4. 03-XL 703-2 /4" XL 7.83 2.48 2.9 6.0 0-XL 7040-6 2" XL 9.92 3.3 3.8 4.0 *XL Denotes Extra Long Alüminyum Döküm Kondulet : Boru tesisat nda dirsek olarak dönüfllerde, kablo çekmede ve tesisat içindeki kablolardan ek almakta kullan l r. Vidal kapa sayesinde kablo ek yerlerine müdahaleyi kolaylaflt r r. Certification E4 LR792 Standards UL4B CSA C22.2 No. 8 NEMA FB- NEC Article 34 & 346 Certification E4 LR792 Standards UL4B CSA C22.2 No. 8 NEMA FB- NEC Article 34 & 346 Certification E2488 LR792 Standards UL4B CSA C22.2 No. 8 NEMA FB- NEC Article 34 & 346 Mogul Conduit Bodies (Type LB) Mogul conduit bodies are used to gain greater access to the interior of a raceway for wire pulling, inspection and maintenance where the raceway changes direction. Assembled with Cover and Gasket Meets NEC 6x Requirement Listed for Use in Wet Locations Materials Die-Cast Aluminum B 23 Catalog UPC No Trade Nominal Dimensions Pcs Ctn/Case Case 02-28 28-9 /4" 9.6 2. 2.78-2 3.8 02-29 29-6 /2" 4.48 3.24.3-4.9 02-30 30-2 2" 4.48 3.24.34-4. Alüminyum Döküm Kondulet : Boru tesisatlar nda kablo çekmede ve farkl seviyelerden gelen kablolar n birlefltirilmesinde kullan l r. Certification E2488 LR792 Standards UL4B CSA C22.2 No. 8 NEMA FB- NEC Article 34 & 346
IMC - RMC Conduit Fittings / IMC - RMC Boru Aksesuarlar Rigid Threaded Nipples Threaded nipples are used to extend a length of threaded Rigid or IMC Conduit according to the pipe size and length desired. May also be used to connect two steel outlet boxes or metal enclosures together. Materials Galvanized Steel Galvaniz Çelik Nipel : htiyaç duyuldu unda IMC ve Rigid borular n boylar na ek yapmakta kullan l r. Ayr ca metal kutu ve panolar n birlefltirilmesinde kullan labilir. Number 0-87 Size A B Qty/Qty Wt. 9700 424-2 /2" CLOSE 3/6" 2. 970 426-6 /2" /2" 3/6" 2 6.9 9702 427-3 /2" 2" 3/6" 2 8.6 9703 428-0 /2" 2 /2" 3/6" 2 0.4 9704 426-0 /2" 3" 3/6" 2 2.6 970 4264- /2" 3 /2" 3/6" 2 6.4 9706 4266- /2" 4" 3/6". 9707 4267-2 /2" " 3/6" 6.8 9708 4268-9 /2" /2" 3/6" 2 3.4 9709 4270-2 /2" 6" 3/6" 2 4.0 970 4272-6 /2" 8" 3/6" 2.7 97 4280- /2" 0" 3/6" 2 6.4 972 428-8 /2" 2" 3/6" 2 7.4 973 4284-9 3/4" CLOSE /6" 0 6.0 974 4364-8 3/4" 2" /6" 6 6.4 97 4290-0 3/4" 2 /2" /6" 2 9.4 976 436-3/4" 3" /6" 4.2 977 4300-6 3/4" 3 /2" /6" 0 4.9 978 4304-4 3/4" 4" /6" 6 4.7 979 4306-8 3/4" " /6". 9720 4366-2 3/4" 6" /6" 8. 972 4309-9 3/4" 8" /6" 2 4.8 9722 43-6 3/4" 0" /6" 2 6. 9723 436-7 3/4" 2" /6" 4 6.4 9724 4326-6 " CLOSE /6" 2 4.0 972 424-2 " 2" /6" 2. 9726 426-6 " 2 /2" /6" 2 6.9 9727 427-3 " 3" /6" 2 8.6 9728 428-0 " 3 /2" /6" 2 0.4 9729 426-0 " 4" /6" 2 2.6 9730 4264- " " /6" 2 6.4 973 4266- " 6" /6". 9732 4267-2 " 8" /6" 6.8 9733 4268-9 " 0" /6" 2 3.4 9734 4270-2 " 2" /6" 2 4.0 973 4272-6 /4" CLOSE /6" 2.7 9736 4280- /4" 2" /6" 2 6.4 9737 428-8 /4" 2 /2" /6" 2 7.4 9738 4284-9 /4" 3" /6" 0 6.0 9739 4364-8 /4" 3 /2" /6" 6 6.4 9740 4290-0 /4" 4" /6" 2 9.4 974 436- /4" " /6" 4.2 9742 4300-6 /4" 6" /6" 0 4.9 9743 4304-4 /4" 8" /6" 6 4.7 9744 4306-8 /4" 0" /6". 974 4366-2 /4" 2" /6" 8. 9746 4309-9 /2" CLOSE 7/8" 2 4.8 9747 43-6 /2" 2" 7/8" 2 6. 9748 436-7 /2" 2 /2" 7/8" 4 6.4 9749 4326-6 /2" 3" 7/8" 2 4.0 970 4290-0 /2" 3 /2" 7/8" 2 9.4 97 436- /2" 4" 7/8" 4.2 972 4300-6 /2" " 7/8" 0 4.9 973 4304-4 /2" 6" 7/8" 6 4.7 974 4306-8 /2" 8" 7/8". 97 4366-2 /2" 0" 7/8" 8. 976 4309-9 /2" 2" 7/8" 2 4.8 B 24
IMC - RMC Conduit Fittings / IMC - RMC Boru Aksesuarlar Rigid One Hole Straps Catalog UPC No Trade Nominal Dimensions Pcs Ctn/Case Case One hole straps are used for providing support for Rigid or IMC Conduit as required by the National Electrical Code. Click-On Type Tek Delikli Krofle : IMC ve Rigid borular n sabitlenmesinde kullan l r. Materials Stamped Steel Finish Zinc Plated 9320 09320-2 /2".8 0.62 0.90-0/00 7.6 932 0932-9 3/4" 2.20 0.7.3-0/00 29.2 9322 09322-6 " 2.60 0.88.32-0/00 42.4 9323 09323-3 /4" 2.9 0.88.64-2/20 29.6 9324 09324-0 /2" 3.62.02.90-2/20 40. 932 0932-7 2" 4.09.4 2.32-2 6.3 936 09326-2 /2" 4.90.2 3.00-2.7 937 09327-2 3".3.2 3.60-2 2.7 938 09328-9 3 /2" 6.8.2 4.3-2 4.2 939 09329-6 4" 6.68.2 4.63-2.7 Certification E 229278 LR792 Rigid One Hole Straps Catalog UPC No Trade Nominal Dimensions Pcs Ctn/Case Case Two hole straps are used for providing support for Rigid or IMC Conduit as required by the National Electrical Code where higher load bearing supports are desired. Click-On Type Çift Delikli Krofle : IMC ve Rigid borular n sabitlenmesinde kullan l r. Materials Stamped Steel Finish Zinc Plated 9340 09340-0 /2" 2.48 0.62 0.87-0/00.8 934 0934-7 3/4" 2.9 0.69 0.98-0/00 4.9 9342 09342-4 " 3.36 0.7.30-2/20 3.2 9343 09343- /4" 4.09 0.88.6-0 3.7 9344 09344-8 /2" 4.40 0.94.90-0.3 934 0934-2". 2.30-0 6.7 Certification E 229278 LR792 Standards UL2239 CSA C22.2 No. 8 NEC Article 34 & 346 B 2
IMC - RMC Conduit Fittings / IMC - RMC Boru Aksesuarlar Threaded and Set Screw Aluminium Conduit Bodies Catalog UPC No Trade Nominal Dimensions Pcs Ctn/Case Case LB Type LR Type LL Type T Type C Type LB Type D600-CGV 708-9 /2" 4.30.30 2.40-30 3. D60-CGV 74-0 3/4".00.0 2.60-8 4. D602-CGV 720- ".80.80 2.90-6 3. D603-CGV 726-3 /4" 7.80 2.0 3.70-8 2. D604-CGV 732-4 /2" 7.80 2.0 3.90-8 2.7 D60-CGV 738-6 2" 9.80 3.20 4.70-2 4. LR Type D00-CGV 600-6 /2" 4.40 2.0.60-27.6 D0-CGV 606-8 3/4".0 2.30.90-2.4 D02-CGV 62-9 ".80 2.0 2.0-4 3. D03-CGV 68- " /4" 7.80 3.40 2.90-4 3. D04-CGV 624-2 " /2" 7.80 3.40 2.90-4 3.0 D0-CGV 630-3 2" 9.90 4.00 3.70-2 4.9 LL Type D200-CGV 636- /2" 4.40 2.0.60-27.6 D20-CGV 642-6 3/4".0 2.30.90-2.3 D202-CGV 648-8 ".80 2.0 2.0-4 3. D203-CGV 64-9 /4" 7.80 3.40 2.90-4 3.0 D204-CGV 660-0 /2" 7.80 3.40 2.90-4 2.7 D20-CGV 666-2 2" 9.90 4.00 3.70-2 4.8 T Type D700-CGV 744-7 /2" 4.80 2.0.60-6.7 D70-CGV 70-8 3/4".0 2.30.90-2 2.4 D702-CGV 76-0 " 6.20 2.0 2.0-3.2 D703-CGV 762- /4" 8.30 3.40 2.90-2 3.3 D704-CGV 768-3 /2" 8.30 3.40 2.90-2 2.9 D70-CGV 774-4 2" 0.20 4.00 3.70-2 4.9 C Type D300-CGV 672-3 /2" 4.80.30.60 -.6 D30-CGV 678-3/4".0.0.90-2.3 D302-CGV 684-6 " 6.20.80 2.0-3.0 D303-CGV 690-7 /4" 8.30 2.0 2.90-2 2.9 D304-CGV 696-9 /2" 8.30 2.0 2.90-2 2.4 D30-CGV 704-2" 0.20 3.20 3.70-2 4.7 X Type 400-CG 72630-8 /2" 4.7.30.60 -.6 40-CG 7263-3/4".0.0.90-2.3 402-CG 72632-2 " 6.20.80 2.0-3.0 403-CG 72633-9 /4" 8.30 2.0 2.90-2 2.9 404-CG 72634-6 /2" 8.30 2.0 2.90-2 2.4 40-CG 7263-0 2" 0.20 3.20 3.70-2 4.7 X Type Conduit bodies are used to gain access to the interior of a raceway for wire pulling, inspection and maintenance where the raceway changes direction. Assembled with Cover and Gasket Materials Die-Cast Aluminum Certification E2488 LR792 Standards UL 4B CSA C22.2 No. 8 NEMA FB- NEC Article 34 & 346 Alüminyum Döküm Konduletler : Boru tesisatlar nda kablo çekmede, kablolara ek yapmakta, mevcut kablo sisteminden ek almakta kullan l r. Aç labilir kapaklar sayesinde bak m ve kolay müdahale avantajlar vard r. Contalar sayesinde s zd rmazl a sahiptirler. B 26
IMC - RMC Conduit Fittings / IMC - RMC Boru Aksesuarlar Threaded Malleable Iron Conduit Bodies LB Type LR Type LL Type T Type C Type X Type Catalog UPC No Trade Nominal Dimensions Pcs Ctn/Case Case LB Type M600 800-0 /2" 4.30.30 2.40-0 7. M60 80-7 3/4".00.0 2.60-0 9.7 M602 802-4 ".80.80 2.90-0 4.3 M603 803-0 /4" 7.80 2.0 3.70-0 28.7 M604 804-8 /2" 7.80 2.0 3.90-0 33.2 M60 80-0 2" 9.80 3.20 4.70-26.7 LR Type M00 830-6 /2" 4.40 2.0.60-0 7. M0 83-2 3/4".0 2.30.90-0 0.0 M02 832-8 ".80 2.0 2.0-0.7 M03 833-4 " /4" 7.80 3.40 2.90-0 33.2 M04 834-7 " /2" 7.80 3.40 2.90-0 34. M0 83-3 2" 9.90 4.00 3.70-3.3 LL Type M200 820-8 /2" 4.40 2.0.60-0 7.6 M20 82-0 3/4".0 2.30.90-0 9. M202 822-2 ".80 2.0 2.0-0 3.8 M203 823-9 /4" 7.80 3.40 2.90-0 30.9 M204 824-6 /2" 7.80 3.40 2.90-0 33.2 M20 82-3 2" 9.90 4.00 3.70-24.9 T Type M700 840-2 /2" 4.80 2.0.60-0. M70 84-8 3/4".0 2.30.90-0 3.7 M702 842-4 " 6.20 2.0 2.0-0 9.6 M703 843-0 /4" 8.30 3.40 2.90-0 33.2 M704 844-3 /2" 8.30 3.40 2.90-0 36.8 M70 84-9 2" 0.20 4.00 3.70-2 3.3 C Type M300 80-9 /2" 4.80.30.60-0 9.8 M30 8-6 3/4".0.0.90-0.8 M302 82-3 " 6.20.80 2.0-0 7.0 M303 83-0 /4" 8.30 2.0 2.90-0 30.9 M304 84-7 /2" 8.30 2.0 2.90-0 36.8 M30 8-4 2" 0.20 3.20 3.70-27.6 X Type 40-CG 72636-0 /2" 4.7.30.60-0 3.9 4-CG 72637-7 3/4".0.0.90-0 7.2 42-CG 72638-4 " 6.20.80 2.0-0 24.7 43-CG 72639- /4" 8.30 2.0 2.90-0 4.6 44-CG 72640-7 /2" 8.30 2.0 2.90-0 46.3 4-CG 7264-4 2" 0.20 3.20 3.70-2 6.7 *2 /2" - 4" Available upon request except "X" type. Conduit bodies are used to gain access to the interior of a raceway for wire pulling, inspection and maintenance where the raceway changes direction. Assembled with Cover and Gasket Materials Malleable Iron Sfero Döküm Konduletler : Boru tesisatlar nda kablo çekmede, kablolara ek yapmakta, mevcut kablo sisteminden ek almakta kullan l r. Aç labilir kapaklar sayesinde bak m ve kolay müdahale avantajlar vard r. Contalar sayesinde s zd rmazl a sahiptirler. Certification E2488 LR792 Standards UL 4B CSA C22.2 No. 8 NEMA FB- NEC Article 34 & 346 B 27
Liquidtight Conduit Fittings/S v S zd rmaz Spiral Boru Aksesuarlar Straight Liquid-Tight Connectors Straight liquid-tight connectors are used to terminate and seal Liquid -Tight Flexible Nonmetallic Type B Conduit to either an oil-tight, liquid-tight or rain-tight box or enclosure. Connectors can be used with tapered thread female entry or unthreaded knock-out using the provided sealing washer and locknut. Resists Salt Water, Weak Acids, Gasoline, Alcohol, Oil, Grease and Common Solvents No Disassembly Required Reusable Materials Nylon Catalog Number UPC No 0-87 Trade Size Nominal Dimensions A B Ctn/Case Qty/Qty Case Wt. 706 0706-4 3/8.44 2.3 20 2.0 700 0700-2 /2.63 2.0 2/00 0.0 70 070-9 3/4.94 2.8 20 2. 702 0702-6 2.2 3.44 0 2. 703 0703-3 /4 2.69 4.2 /0 2.0 704 0704-0 /2 3.3 4.69 /20 4.0 70 070-0 2 3.63.3 2/20 9.0 PVC Kapl Çelik Spiral Boru Sonland rma Rakoru (Metal olmayan) : S v s zd rmaz PVC kapl çelik spiral borular n kutu, buat, pano vb. girifllerinde sonland r lmas ve sabitlenmesi amac yla kullan l r. S v s zd rmaz özelli i vard r. Contas ve kilitleme somunu ile birlikte sat l r. 90 Liquid-Tight Connectors 90 liquid-tight connectors are used to terminate and seal Liquid-Tight Flexible Nonmetallic Type B Conduits at 90 angles to either an oil-tight, liquid-tight or rain-tight box or enclosure. Connectors can be used with tapered thread female entry or unthreaded knock-out using the provided sealing washer and locknut. Resists Salt Water, Weak Acids, Gasoline, Alcohol, Oil, Grease and Common Solvents No Disassembly Required Reusable Materials Nylon Catalog Number UPC No 0-87 Trade Size Nominal Dimensions A B Ctn/Case Qty/Qty Case Wt. 76 076-3 3/8 2.00.40 20 2.2 70 070- /2 2.00.40 20 2.2 7 07-8 3/4 2..68 20 2.8 72 072-2.2 2.00 0 2. 73 073-2 /4.26.20 2/20 8.0 74 074-9 /2.43.46 2/20 0.0 7 07-6 2.8.78 /0 9.0 PVC Kapl Çelik Spiral Boru Sonland rma Rakoru (Metal olmayan) : S v s zd rmaz PVC kapl çelik spiral borular n kutu, buat, pano vb. girifllerinde 90 ile sonland r lmas ve sabitlenmesi amac yla kullan l r. S v s zd rmaz özelli i vard r. Contas ve kilitleme somunu ile birlikte sat l r. B 28
Straight Liquid-Tight Connectors Straight liquid-tight connectors are used to terminate and seal Liquid-Tight Flexible Metal and Liquid-Tight Flexible Nonmetallic Type B Conduits to either an oil-tight, liquid-tight or rain-tight box or enclosure. Connectors can be used with tapered thread female entry or unthreaded knock-out using the provided sealing washer and locknut. Furnished with Sealing Ring Suitable for Grounding (up to /4") PVC Kapl Çelik Spiral Boru Zamak Sonland rma Rakoru : S v s zd rmaz PVC kapl çelik spiral borular n kutu, buat, pano vb. girifllerde sonland r l p, sabitlenmesi amac yla kullan l r. Ya murun, ya n ve s v lar n tesisat n içerisine girmesini önler. Kilitleme somunu ve tüm aksesuarlar ile birlikte sat l r. Straight Liquid-Tight Connectors (Malleable Iron) Straight liquid-tight connectors are used to terminate and seal Liquid-Tight Flexible Metal and Liquid-Tight Flexible Nonmetallic Type B Conduits to either an oil-tight, liquid-tight or rain-tight box or enclosure. Connectors can be used with tapered thread female entry or unthreaded knock-out using the provided sealing washer and locknut. Tapered threaded male hub - NPT Compact, slim diameter Steel locknut Liquidtight/Raintight/Oiltight Suitable for wet locations Long ferrule prevents pullout & tight bend conduit pop out Materials Malleable Iron PVC Kapl Çelik Spiral Boru Döküm Sonland rma Rakoru : S v s zd rmaz PVC kapl çelik spiral borular n kutu, buat, pano vb. girifllerde sonland r l p, sabitlenmesi amac yla kullan l r. Ya murun, ya n ve s v lar n tesisat n içerisine girmesini önler. Kilitleme somunu ve tüm aksesuarlar ile birlikte sat l r. CONDUIT FITTINGS Liquidtight Conduit Fittings/S v S zd rmaz Spiral Boru Aksesuarlar Number 0-87 Size A B C Qty/Qty Wt. 8248 08248-0 3/8" 2.80 2.9 0.66 2/00 6.8 830 0830-4 /2".0.22 0.0 2/00 3.9 83 083-3/4".60.48 0.0 0/00 20. 832 0832-8 " 2.00.7 0.68 /2 8.3 833 0833- /4" 2.24 2.23 0.68 /2 2.2 834 0834-2 /2" 2.0 2.48 0.66 2/0.9 83 083-9 2" 2.80 2.9 0.66 2/0 7. 836 0836-6 2 /2" 2.00.7 0.68 2.0 837 0837-3 3" 2.24 2.23 0.68 2.4 838 0838-0 3 /2" 2.0 2.48 0.66 3.2 839 0839-7 4" 2.80 2.9 0.66 3.7 w/ insulated throat 8249 08249-7 3/8" 2.80 2.9 0.66 2/00 6.8 8320 08320-3 /2".0.22 0.0 2/00 3.9 832 0832-0 3/4".60.48 0.0 0/00 20. 8322 08322-7 " 2.00.7 0.68 /2 8.3 8323 08323-4 /4" 2.24 2.23 0.68 /2 2.2 8324 08324- /2" 2.0 2.48 0.66 2/0.9 832 0832-8 2" 2.80 2.9 0.66 2/0 7. 8326 08326-2 /2" 2.00.7 0.68 2.0 8327 08327-2 3" 2.24 2.23 0.68 2.4 8328 08328-9 3 /2" 2.0 2.48 0.66 3.2 8329 08329-6 4" 2.80 2.9 0.66 3.7 Standards E4 LR792 UL 4B CSA C22.2 No. 8 NEMA FB- NEC Article 3 Number 0-87 Size A B C Qty/Qty Wt. 9376 09376-9 3/8" /8" /2" /8" 2/00.4 9370 09370-7 /2" /4" /2" /4" 2/00 7.6 937 0937-4 3/4" /4" /2" 9/6" 0/00 28.7 9372 09372- " 7/6" /8" 3/6" /0 9.9 9373 09373-8 /4" /2" /6" 2 /4" /0 27.6 937 0937-0 2" 3/4" 3/4" 3" 2/20 9.8 9427 9427-8 2 /2" 2 3/6" " 4" 3.6 9428 9428-3" 2 /2" /8" 4 3/6" 4.6 9429 09429-0 3 /2" 2 /8" 3/6" /4" 6.7 9430 09430-8 4" 2 3/4" /4" 3/4" 7.9 9374 09374- /2" /8" 3/4" 2 7/6" 2/20 4. w/ insulated throat 9386 09386-8 3/8" /8" 9/6" /8" 2/00.4 9380 09380-6 /2" /4" 9/6" /4" 2/00 7.6 938 0938-3 3/4" /4" 9/6" 9/6" 0/00 28.7 9382 09382-0 " 7/6" /6" 3/6" /0 9.9 9383 09383-7 /4" /2" 3/4" 2 /4" /0 27.6 9384 09384-4 /2" /8" 3/6" 2 7/6" 2/20 4. 938 0938-2" 3/4" 3/6" 3" 2/20 9.8 943 0943-2 /2" 2 3/6" /6" 4" 3.6 9432 09432-0 3" 2 /2" 3/6" 4 3/6" 4.6 9433 09433-9 3 /2" 2 /8" /4" /4" 6.7 9434 09434-6 4" 2 3/4" /6" 3/4" 7.9 * UL Listed liquidtight flexible metal conduit fittings are suitable for use in the following hazardous locations under NEC 0-4(b), 02-4(a)(2); Class I, Div. 2; Class II, Div. and 2; and Class III, Div. and 2. Certification E20787 Standards UL 4B NEMA FB- B 29
Liquidtight Conduit Fittings/S v S zd rmaz Spiral Boru Aksesuarlar 90 Liquid-Tight Connectors 90 liquid-tight connectors are used to terminate and seal Liquid-Tight Flexible Metal and Liquid- Tight Flexible Nonmetallic Type B Conduits at 90 angles to either an oil-tight, liquid-tight or rain-tight box or enclosure. Connectors can be used with tapered thread female entry or unthreaded knockout using the provided sealing washer and locknut. UL Listed Locknut Furnished with Sealing Ring Suitable for Grounding (up to /4 ) Materials Certification E4 LR792 PVC Kapl Çelik Spiral Boru Zamak 90º Sonland rma Rakoru : S v s zd rmaz PVC kapl çelik spiral borular n kutu, buat, pano vb. girifllerde 90 ile sonland r lmas ve sabitlenmesi amac yla kullan l r. S v s zd rmaz özelli i vard. Contas ve kilitleme somunu ile birlikte sat l r. Number 0-87 Size A B C Qty/Qty Wt. 8246 08246-6 3/8.0.2 0.0 0/0.9 8380 08280-0 /2.2.2 0.0 0/0. 838 0828-7 3/4.60.37 0.3 0/0 27. 8382 08282-4 2.00.73 0.69 /2. 8383 08283- /4 2.24 2.3 0.67 /2 9.8 8384 08284-8 /2 2.0 2.44 0.67 2/0 0.3 838 0828-2 2.80.7 0.67 2/0 3.0 8386 08286-2 2 /2 2.00.7 0.68 3.6 8387 08287-9 3 2.24 2.23 0.68.6 8388 08288-6 3 /2 2.0 2.48 0.66 2.7 8389 08289-3 4 2.80 2.9 0.66 3.3 w/ insulated throat 8247 08247-3 3/8 2.80 2.9 0.66 0/0.9 8390 08290-9 /2.0.22 0.0 0/0. 839 0829-6 3/4.60.48 0.0 0/0 27. 8392 08292-3 2.00.7 0.68 /2. 8393 08293-0 /4 2.24 2.23 0.68 /2 9.8 8394 08294-7 /2 2.0 2.48 0.66 2/0 0.3 839 0829-4 2 2.80 2.9 0.66 2/0 3.0 8396 08296-2 /2 2.00.7 0.68 3.6 8397 08297-8 3 2.24 2.23 0.68.6 8398 08298-3 /2 2.0 2.48 0.66 2.7 8399 08299-2 4 2.80 2.9 0.66 3.3 Standards UL 4B CSA C22.2 No. 8 NEMA FB- NEC Article 3 90 Liquid-Tight Connectors LIQUID TIGHT 90 Liquid-Tight Connectors (Malleable Iron) 90 liquid-tight connectors are used to terminate and seal Liquid-Tight Flexible Metal and Liquid- Tight Flexible Nonmetallic Type B Conduits at 90 angles to either an oil-tight, liquid-tight or rain-tight box or enclosure. Connectors can be used with tapered thread female entry or unthreaded knockout using the provided sealing washer and locknut. UL Listed Locknut Furnished with Sealing Ring Suitable for Grounding (up to /4") Materials Malleable Iron PVC Kapl Çelik Spiral Boru Döküm 90º Sonland rma Rakoru : S v s zd rmaz PVC kapl çelik spiral borular n kutu, buat, pano vb. girifllerinde 90 ile sonland r lmas ve sabitlenmesi amac yla kullan l r. S v s zd rmaz özelli i vard. Contas ve kilitleme somunu ile birlikte sat l r. Number 0-87 Size A B C Qty/Qty Wt. 946 09376-9 3/8 /6" /2" /8" 0/00 2.4 940 09370-7 /2 7/6" /2" /4" 0/00 28.9 94 0937-4 3/4 /8" /2" 9/6" 0/00 44. 942 09372-2 /6" /8" 3/6" /0 37.3 943 09373-8 /4" 2 3/8" /6" 2 /4" 2/20 9.2 944 0937-0 /2" 3 /6" 3/4" 27/6" 2/20 24.3 94 9427-8 2" 3 3/6" 3/4" 3" /0 7.6 9478 9428-2 /2" 8 /6" " 4" 8.4 9479 09429-0 3" 9 3/6" /8" 4 3/6" 2.4 9480 09430-8 3 /2" 3/6" 3/6" /4" 9.0 948 09374-4" 3" /4" 3/4" 23.8 w/ insulated throat 9426 0946-2 3/8" /8" 9/6" /8" 0/00 2.7 9420 0940-0 /2" /4" 9/6" /4" 0/00 29.2 932 094-7 3/4" /4" 9/6" 9/6" 0/00 44.6 9322 0942-4 " 7/6" /8" 3/6" /0 37.7 9323 0943- /4" /2" 3/4" 2 /4" 2/20.6 9324 0944-0 /2" /8" 3/6" 2 7/6" 2/20 2.7 932 094-2" 3/4" 3/6" 3" /0 3.3 9482 09478-0 2 /2" 2 3/6" /6" 4" 3.6 9483 09479-7 3" 2 /2" 3/6" 4 3/6".6 9484 09480-3 3 /2" 2 /8" /4" /4" 2.7 948 0948-0 4" 2 3/4" /6" 3/4" 3.3 Certification E20787 Standards UL 4B NEMA FB- B 30
Flexible Steel Conduit Fittings/ Galvaniz Çelik Spiral Boru Aksesuarlar Screw-In Greenfield Connectors Screw-in type connectors are used to terminate Flexible Metal Conduit to a knock-out in a dry location box or enclosure, where minimum spacing is desired between the conduits. Zamak Spiral Çelik Boru Rakoru: Çelik spiral borular n pano, buat, armatür ve benzeri yerlerde sonland r lmas nda kullan l r. 836 0836-2 3/8".30 0.92 0.4-0/00 24.4 830 0830-0 /2".37 0.92 0.4-0/00 26.24 83 083-7 3/4".63.2 0.43-2/20 20.2 832 0832-4 ".92.3 0.6-2/20 39.7 833 0833- /4" 2.2.7 0.6-0/00 22. 834 0834-8 /2" 2.32 2. 0.62-0/40 4.2 83 083-2" 2. 2.66 0.7-0/40 22.3 w/ Insulated Throat 8360 08360-9 /2".37 0.92 0.4-0/00 26.24 836 0836-6 3/4".63.2 0.43-2/20 20.2 8362 08362-3 ".92.3 0.6-2/20 39.7 8363 08363-0 /4" 2.2.7 0.6-0/00 22. 8364 08364-7 /2" 2.32 2. 0.62-0/40 4.2 836 0836-4 2" 2. 2.66 0.7-0/40 22.3 E4 UL 4B CSA C22.2 No. 8 NEMA FB- NEC Article 30 LR792 Trade Size For Cable Sizes 3/8" For Regular Wall Steel or Aluminum Flexible Metal Conduit. /2" For Regular Wall Steel or Aluminum Flexible Metal Conduit. 3/4" For Regular or Reduced Wall Steel or Aluminum Flexible Metal Conduit. "-2 For Regular Wall Steel or Aluminum Flexible Metal Conduit. Screw-In Greenfield Couplings 8370 08370-8 /2.79 0.97 0.20-0/00 23. 830 0830-0 3/4 2.00.2 0.22-2/20 9.84 Screw-in type couplings are used to join lengths of Flexible Metal Conduit. Zamak Spiral Çelik Boru Ek Mufu: Çelik spiral borular n birbirine eklenmesinde kullan l r. E4 LR792 UL 4B CSA C22.2 No. 8 NEMA FB- NEC Article 308 B 3
Flexible Steel Conduit Fittings/ Galvaniz Çelik Spiral Boru Aksesuarlar 90 Angle Connectors 90 connectors are used to make a 90 termination of Armored Cable, Metal Clad Cable or Flexible Metal Conduit to a knock-out or unthreaded slip hole in a dry location box or enclosure. 90º Zamak Spiral Çelik Boru Rakoru: Çelik spiral borular n ve z rhl kablolar n buat, pano,armatür ve benzeri yerlerde 90º girifl ile sonland r lmas nda kullan l r. Squeeze Type E4 LR792 UL 4B CSA C22.2 No. 8 NEMA FB- NEC Articles 30, 333 & 334 8200 08200-8 3/8".32.30 0.39-0/00 44.8 880 0880-3 /2".64.63 0.43-2/20 3. 88 088-0 3/4".77.89 0.43-0/00 8. 882 0882-7 " 2.3 2.30 0.3-0 3.2 883 0883-0 /4" 3.00 2.69 0.9-0 4.8 884 0884-7 /2" 4.80 3.9 0.70-4 4.4 88 088-4 2" 4.80 3.9 0.70-4 4.6 886 0886-2 /2" 4.80 4.4 0.8-2.9 887 0887-2 3".8.00 0.8-3. 888 0888-9 3 /2" 6.4..02-6.3 889 0889-6 4" 7.22 6.0.06-7.4 w/ insulated throat 820 0820-3/8".32.30 0.39-0/00 44.8 890 0890-2 /2".64.63 0.43-2/20 3. 89 089-9 3/4".77.89 0.43-0/00 8. 892 0892-6 " 2.3 2.30 0.3-0 3.2 893 0893-3 /4" 3.00 2.69 0.9-0 4.8 894 0894-0 /2" 4.80 3.9 0.70-4 4.4 89 089-7 2" 4.80 3.9 0.70-4 4.6 896 0896-4 2 /2" 4.80 4.4 0.8-2.9 897 0897-3".8.00 0.8-3. 898 0898-8 3 /2" 6.4..02-6.3 899 0899-4" 7.22 6.0.06-7.4 Trade Size For Cable Sizes 3/8" For regular Wall Steel or Aluminum Flexible Metal Conduit. For 4-2 through 0-3 Steel or Aluminum Armored Cable. For 4-2 through 0-3 Interlocking Steel or Aluminum Metal clad Cable. /2" For Regular Wall Steel or Aluminum Flexible Metal Conduit. For 8-2 through 8-3 Steel or Aluminum Armored Cable. For 8-2 through 8-3 interlocking Steel or Aluminum Metal clad Cable. 3/4" For regular or Reduced Wall Steel or Aluminum Flexible Metal Conduit. 90 Angle Connectors (Malleable Iron) 90 connectors are used to make a 90 termination of Armored Cable, Metal Clad Cable or Flexible Metal Conduit to a knock-out or unthreaded slip hole in a dry location box or enclosure. 90º Dövme Demir Spiral Çelik Boru Rakoru: Çelik spiral borular n ve z rhl kablolar n buat, pano,armatür ve benzeri yerlerde 90º girifl ile sonland r lmas nda kullan l r. Squeeze Type Malleable Iron E4 LR792 UL 4B CSA C22.2 No. 8 NEMA FB- NEC Articles 30, 333 & 334 930 0930- /2".64.63 0.43-2/20 3. 93 093-2 3/4".77.89 0.43-0/00 8. 932 0932-9 " 2.3 2.30 0.3-0 3.2 933 0933-6 /4" 3.00 2.69 0.9-0 4.8 934 0934-3 /2" 4.80 3.9 0.70-4 4.4 93 093-0 2" 4.80 3.9 0.70-4 4.6 936 0936-7 2 /2" 4.80 4.4 0.8-2.9 937 0937-4 3".8.00 0.8-3. 938 0938-3 /2" 6.4..02-6.3 939 0939-8 4" 7.22 6.0.06-7.4 w/ insulated throat 930I 9930-8 /2".64.63 0.43-2/20 3. 93I 993-3/4".77.89 0.43-0/00 8. 932I 9932-2 " 2.3 2.30 0.3-0 3.2 933I 9933-9 /4" 3.00 2.69 0.9-0 4.8 934I 9934-6 /2" 4.80 3.9 0.70-4 4.4 93I 993-3 2" 4.80 3.9 0.70-4 4.6 936I 9936-0 2 /2" 4.80 4.4 0.8-2.9 937I 9937-7 3".8.00 0.8-3. 938I 9938-4 3 /2" 6.4..02-6.3 939I 9939-4" 7.22 6.0.06-7.4 B 32
Squeeze Connectors CONDUIT FITTINGS Flexible Steel Conduit Fittings/ Galvaniz Çelik Spiral Boru Aksesuarlar Squeeze connectors are used to terminate Flexible Metal Conduit to a knock-out in a dry location box or enclosure. Squeeze Type Zamak Spiral Çelik Boru Rakoru : Çelik spiral borular n ve z rhl kablolar n kutu ve panolara ba lant s nda kullan l r. E4 LR792 UL 4B CSA C22.2 No. 8 NEMA FB- NEC Article 30 837 0837-3 3/8".09 0. 0.62-0/00 32.0 8380 08380-7 /2".0 0. 0.99-2/20 2.6 838 0838-4 3/4".9 0..8-2/20 33.7 8382 08382- ".7 0..4-0/00 2.0 8383 08383-8 /4".90 0.6.73-0/00 28.0 8384 08384- /2" 2.00 0.6 2.00 - /0 8.0 838 0838-2 2" 2.0 0.6 2. - 0/40 8.4 8386 08386-9 2 /2".7 0..4-4. 8387 08387-6 3".90 0.6.73 - / 2.7 8388 08388-3 3 /2" 2.00 0.6 2.00 -.7 8389 08389-0 4" 2.0 0.6 2. - 2. w/ insulated throat 8390 08390-6 /2".0 0. 0.99-2/20 2.6 839 0839-3 3/4".9 0..8-2/20 33.7 8392 08392-0 ".7 0..4-0/00 2.0 8393 08393-7 /4".90 0.6.73-0/00 28.0 8394 08394-4 /2" 2.00 0.6 2.00 - /0 8.0 839 0839-2" 2.0 0.6 2. - 0/40 8.4 8396 08396-8 2 /2".7 0..4-9.0 8397 08397-3".90 0.6.73 - / 2.7 8398 08398-2 3 /2" 2.00 0.6 2.00 -.7 8399 08399-9 4" 2.0 0.6 2. - 2. Trade Size For Cable Sizes 3/8" For Regular or Reduced Wall Steel Flexible Metal Conduit. For 2-2 through 0-3 Steel or Aluminum aromored cable. For 2-2 through 0-3 Interlocking Steel or Aluminum Metal Clad Cable. 3/4" For Regular or Reduced Wall Steel or Aluminum Flexible Metal Conduit. /2" For Regular or Reduced Wall Steel Flexible Metal Conduit. For 6-3 Steel or Aluminum Aromored Cable. For 6-3 Interlocking Steel or Aluminum Metal Clad Cable. Squeeze Connectors (Malleable Iron) Squeeze connectors are used to terminate Flexible Metal Conduit to a knock-out in a dry location box or enclosure. Squeeze Type Malleable Iron Döküm Spiral Çelik Boru Rakoru : Çelik spiral borular n kutu ve panolara ba lant s nda kullan l r. E4 LR792 UL 4B CSA C22.2 No. 8 NEMA FB- NEC Article 30 980 0980-0 /2".0 0. 0.99-2/2 6.6 98 098-7 3/4".9 0..8-20/00 6.7 982 0982-4 ".7 0..4-0/0 3.0 983 0983- /4".90 0.6.73-0/0 20.0 984 0984-8 /2" 2.00 0.6 2.00 - /2.8 98 098-2" 2.0 0.6 2. - 20 2.4 986 0986-2 2 /2".7 0. 2.00-8.6 987 0987-9 3".90 0.6.73-0. 988 0988-6 3 /2" 2.00 0.6 2.00-4.4 989 0989-3 4" 2.0 0.6 2. - 6.6 w/ insulated throat 980I 9980-3 /2".0 0. 0.99-2/2 6.8 98I 998-0 3/4".9 0..8-20/00 6.9 982I 9982-7 ".7 0..4-0/0 3. 983I 9983-4 /4".90 0.6.73-0/0 20. 984I 9984- /2" 2.00 0.6 2.00 - /2.9 98I 998-8 2" 2.0 0.6 2. - 20 2.6 986I 9986-2 /2".7 0..4-8.7 987I 9987-2 3".90 0.6.73-0.2 988I 9988-9 3 /2" 2.00 0.6 2.00-4. 989I 9989-6 4" 2.0 0.6 2. - 6.7 B 33
Flexible Steel Conduit Fittings/ Galvaniz Çelik Spiral Boru Aksesuarlar BX Connectors Number 0-87 Size A B C Qty/Qty Wt. 820 0820-3 3/8" 0.78 0.63 0.36 00/000 46.7 BX connectors are used to terminate steel Armored Cable to a /2 knock-out in a dry location box or enclosure. End Stopped Zamak Z rhl Kablo Kutu Ba lant Rakoru : Z rhl kablolar n kutu ve panolara ba lant s nda kullan l r. Trade Size For Cable Sizes 3/8" For 4-2 (nominal OD.460 ) through 0-2 (nominal OD.98 ) Steel Armored Cable. For 4-2 (nominal OD.469 ) through 0-3 (nominal OD.600 ) Steel Interlocking Metal Clad Cable. E4 LR792 UL 4B CSA C22.2 No. 8 NEMA FB- NEC Articles 333 Set Screw Flex Connectors Number 0-87 Size A B C Qty/Qty Wt. 824 0824-7 /2" 0.9.0 0.40 0/20.7 824 0824-3/4.. 0.49 /60. Set screw flex connectors are used to terminate Regular Wall Steel or Aluminum Flexible Metal Conduit to a Knock-out in a dry location box or enclosure. Set Screw E4 LR792 Zamak Kutu Ba lant Rakoru : Metal borular n ve alüminyum spiral borular n kutu ve panolara ba lant s nda kullan l r. UL 4B CSA C22.2 No. 8 NEMA FB- NEC Articles 333 Combination Connectors Number 0-87 Size A B C Qty/Qty Wt. Clamp type connectors are used to terminate Armored cable, Metal Clad Cable or Flexible Metal Conduit to a /2 knock-out in a dry box or enclosure. Metal Hub Threads NPS End Stopped Zamak Kutu Ba lant Aparat : Spiral metal borular n, z rhl kablolar n kutu ve panolara /2 delik çap nda ba lant s nda kullan l r. 8244 08244-2 3/8" 0.80.7 0.3 00/000 0. Trade Size For Cable Sizes 3/8" For Regular Wall Steel or Aluminum Flexible Metal Conduit. For 4-2 through 0-2 Steel or Aluminum Armored Cable. For 4-2 (nominal OD.600 ) Steel Interlocking Metal Clad Cable. Aluminum Interlocking Metal Clad Cable; 4-2 (nominal OD.469 ) E4 LR792 UL 4B CSA C22.2 No. 8 NEMA FB- NEC Articles 333 B 34
Saddle Connectorð CONDUIT FITTINGS Flexible Steel Conduit Fittings/ Galvaniz Çelik Spiral Boru Aksesuarlar Saddle connectors are used to terminate Armored and Metal Clad Cables to a /2" knock-out in a dry location box or enclosure. UL Listed Locknut End Stopped Zamak Kutu Ba lant Aparat : Z rhl kablolar n kutu ve panolara /2 delik çap nda ba lant s nda kullan l r. Number 0-87 Size A B C Qty/Qty Wt. 8460 08460-6 3/8" 0.90.6 0.93 0/00 3.4 Trade Size For Cable Sizes 3/8" For 4-2 (nominal OD.46") through 0-3 (nominal OD.00") Steel Armored Cable; For 4-2 (nominal OD.480") through 0-3 (nominal OD.8") Aluminum Armored Cable. For 0.47 through 0.600 Steel Interlocking Metal Clad Cable. For 0.468 through 0.60 Aluminum Interlocking Metal Clad Cable. For 2/2 through 0/3 Oval NMSE Cable. E4 LR792 UL 4B CSA C22.2 No. 8 NEMA FB- NEC Articles 333 Strap Connector Strap Connectors are used to terminate Armored Cable and Metal Clad to a steel outlet box or metal enclosure. Zamak Kutu Ba lant Aparat : Z rhl kablolar n kutu ve panolara /2 delik çap nda ba lant s nda kullan l r. Number 0-87 Size A B C Qty/Qty Wt. 8264 08464-4 /2".40.80 0.40 2/20 2.6 Trade Size For Cable Sizes 3/8" For 8-4 (nominal OD.78") through 8-2 (nominal OD.680") Steel Armored Cable; For 8-4 (nominal OD.780") through 8-2 (nominal OD.680") Aluminum Armored Cable. For 0.680 through 0.780 Steel Interlocking Metal Clad Cable. For 0.67 through 0.780 Aluminum Interlocking Metal Clad Cable. E4 LR792 UL 4B CSA C22.2 No. 8 NEMA FB- NEC Articles 333 Duplex Connectorð Duplex connectors are used to terminate two runs of Armored Cable, Metal Clad Cable or Flexible Metal Conduit to a /2" knock-out in a dry location box or enclosure. Clamp Type Double Screw Zamak kili Kutu Ba lant Aparat : Z rhl kablolar, spiral metal borular n,ikili olarak kutu ve panolara /2 delik çap nda ba lant s nda kullan l r. Catalog UPC No Trade Ctn/Case Case Number 0-87 Size Qty/Qty Wt. 8243 08243-6 3/8" 2/20 26.6 Trade Size For Cable Sizes 3/8" For Regular Wall Steel or Aluminum Flexible Metal Conduit. For 4-2 (nominal OD.460") through 0-3 (nominal OD.00") Steel Armored Cable; For 4-2 (nominal OD.480") through 0-3 (nominal OD.80") Aluminum Armored Cable. For 4-2 (nominal OD.468") through 0-3 (nominal OD.60") Aluminum Interlocking Metal Clad Cable; 4-2 (nominal OD.470") through 0-3 (nominal OD.600") Steel Interlocking Metal Clad Cable. E4 LR792 UL 4B CSA C22.2 No. 8 NEMA FB- NEC Articles 333 B 3
Flexible Steel Conduit Fittings/ Galvaniz Çelik Spiral Boru Aksesuarlar Strap Connector Number 0-87 Size A B C Qty/Qty Wt. Duplex connectors are used to terminate two runs of Armored Cable, Metal Clad Cable or Flexible Metal Conduit to a /2" knock-out in a dry location box or enclosure. Clamp Type Single Screw Zamak kili Kutu Ba lant Aparat : Z rhl kablolar, spiral metal borular n,ikili olarak kutu ve panolara /2 delik çap nda ba lant s nda kullan l r. 8242 08242-8 3/8".60.0 0.42 2/20 26.6 Trade Size For Cable Sizes 3/8" For Regular Wall Steel or Aluminum Flexible Metal Conduit. For 4-2 (nominal OD.460") through 0-3 (nominal OD.00") Steel Armored Cable; For 4-2 (nominal OD.480") through 0-3 (nominal OD.80") Aluminum Armored Cable. For 4-2 (nominal OD.468") through 0-3 (nominal OD.60") Aluminum Interlocking Metal Clad Cable; 4-2 (nominal OD.470") through 0-3 (nominal OD.600") Steel Interlocking Metal Clad Cable. E4 LR792 UL 4B CSA C22.2 No. 8 NEMA FB- NEC Articles 333 EMT To Flex Coupling Number 0-87 Size A B C Qty/Qty Wt. 827 0827-6 /2-3/8" 0.72 0.93.34 0/00 34.3 Combination couplings are used to provide a transition from steel EMT conduit to Flexible Metal Conduit. Set Screw - Clamp Type E20498 LR792 Vidal Zamak EMT-Flex Ba lant Mufu: EMT boru ve çelik spiral borunun birlefltirilmesinde kullan l r. EMT To Flex Coupling Number 0-87 Size A B C Qty/Qty Wt. Combination couplings are used to provide a transition from steel EMT conduit to Flexible Metal Conduit. Set Screw - Clamp Type 828 0828-3 /2 -/2" 0.72 0.93.34 0/00 34.3 829 0829-3 3/4-3/4" 0.72 0.94.62 2/20 2.9 E20498 LR792 Vidal Zamak EMT-Flex Ba lant Mufu: EMT boru ve çelik spiral borunun birlefltirilmesinde kullan l r. B 36
Flexible Steel Conduit Fittings/ Galvaniz Çelik Spiral Boru Aksesuarlar Combination couplings are used to provide a transition from steel EMT conduit to Flexible Metal Conduit. Compression - Screw in Type S kmal Zamak EMT-Flex Ba lant Mufu: EMT boru ve çelik spiral borunun birlefltirilmesinde kullan l r. Number 0-87 Size A B C Qty/Qty Wt. 820 0820-7 /2.40 0.92 0. 0/00 40.9 82 082-4 3/4.2.2 0.20 2/20 30.8 E4 LR792 BX One Hole Strap Number 0-87 Size A B C Qty/Qty Wt. One hole starps are used to provide support for runs of Armored Cable. Galvaniz Çelik Tek Delikli Krofle: Z rhl kablolar sabitlemede kullan l r. 9300 09300-4 3/8".27 0. 0.47 00/000 3.9 930 0930- /2".43 0. 0.47 0/000. Galvanized Steel Zinc Plated Snap-in Flex Number 0-87 Size A B C Qty/Qty Wt. 990 0990-9 /2".44 0.88-0/00 37. 99 099-6 3/4".69.3-2/20 36 Number 0-87 Size A B C Qty/Qty Wt. Snap-in connectors are used to terminate Armored cable. No tools needed Single unit construction eliminates loose component parts, integral green plastic insulated throat bushing provides maximum protection for wire installation. No locknut required Çelik Kablo Sonlama : Z rhl kablolar n sonland r lmas nda kullan l r. Anti-Short Bushing Anti-short bushings are inserted into the end of Armored Cable and Flexible Metal Conduit in order to protect the conductors from the sharp edges of the raceway where cut. Plastic Plastik Kablo ve Spiral Boru Sonlama : Z rhl kablolar n ve spiral çelik borular n sonland r lmas nda kullan l r. 993 0993-0 /2.63.69-20/200 20.4 Steel E238299 Catalog UPC No Trade Ctn/Case Case Number 0-87 Size Qty/Qty Wt. 926 0926-6 0 3/00 9266 09266-3 3/400 2 9267 09267-0 2 3/300 8 9268 09268-7 3 20/200 6 9269 09269-4 4 6/00 9 B 37
Service Entrance Cable Connectors/Kablo Rakorlar ve Aksesuarlar NM / SE Cable Connector NM / SE CABLE Catalog UPC No Trade Wire Ctn/Case Case Number 0-87 Size Size Qty/Qty Wt. Watertight connectors are used for sealing and terminating Oval Type SE or USE Cable to a threaded entry of a watertight box or enclosure. Zamak S v S zd rmaz Diflli Kablo Ba lant Rakoru : UL/NEC tip oval SE ve USE kablolar n pano ve kutu girifllerinde sabitlenmesi ve kablolar n sonland r lmas amac yla kullan l r. 8404 08404-0 3#4 0/00 26 8406 08406-4 3#6 0/00 2 8408 08408-8 3#8 0/00 2 84 084-8 /4 3# 0/0 26 842 0842- /4 3#2 0/0 2 843 0843-2 /4 3#3 0/0 2 840 0840- /2 3#/0 /2 6 8420 08420-0 /2 3#2/0 /2 23 8430 08430-9 2 3#/0 /2 23 843 0843-6 2 3#2/0 /0 4 8432 08432-3 2 3#3/0 /0 4 8440 08440-8 2 3#4/0 /2 23. 8440-L 0847-0 2 3#4/0 /2 23. E40 E23494 LR792 UL 4B, CSA C22.2 No. 8 NEMA FB-, NEC Articles 338 UF Connectors NM / SE CABLE Used to connect underground feeder cable to a weather proof box with threaded hub. For Underground Feeder Cable Only Zamak S v S zd rmaz Diflli Kablo Ba lant Rakoru : UL/NEC tip feeder yeralt kablolar n n pano ve kutu girifllerinde sonland r lmas ve sabitlenmesi amac yla kullan l r. Catalog UPC No Trade Grommet Opening Wire Ctn/Case Case Number 0-87 Size Minimum Maximum Size Qty/Qty Wt. 8376 08376-0 /2".0 x.22.44 x.47 2/2 2/20 24.3 8377 08377-7 3/4".7 x.22.66 x.80 2/3 2/20 38.3 E4 LR792 Mini One Hole Straps NM / SE CABLE Midget one hole straps are used to secure bare solid copper wire to a working surface. Tek Delikli Kablo Sabitleme Kroflesi : Ç plak bak r iletkenlerin sabitlenmesinde kullan l r. One Hole SEU Straps 928 0928-8 3/6 OD 0.69 0.32 0.9-00/000 3.4 929 0929- /4 OD 0.99 0.2 0.23-00/000 6. Stamped Steel Zinc Plated NM / SE CABLE One hole straps are used to secure Type SE or USE Service Entrance Cable. Tek Delikli Kablo Sabitleme Kroflesi : UL/NEC tip SE ve USE kablolar n sabitlenmesi amac yla kullan l r. 920 0920-2 3#8,6,4.39 0.0 0.3-00/000 4.3 92 092-9 3#3,2.69 0.6 0.44-00/000 20.6 922 0922-6 3#,/0,2/0.94 0.6 0.6-2/20 23.6 923 0923-3 3#3/0,4/0 2.0.00 0.84-2/20 22. Stamped Steel Zinc Plated B 38
Service Entrance Cable Connectors/Kablo Rakorlar ve Aksesuarlar Two Hole SEU Straps NM / SE CABLE Two hole straps are used to secure Type SE or USE Service Entrance Cable. Çift Delikli Kablo Sabitleme Kroflesi : UL/NEC tip SE ve USE kablolar n sabitlenmesinde kullan l r. 924 0924-0 #8,6,4 2.38 0.7 0.38-00/000 30.0 92 092-0 #3,2 2.7 0.7 0.0-00/000 34.9 926 0926-4 #,0,/0,2/0 3.9 0.7 0.7-2/20 2.8 927 0927- #3/0-4/0 3.0 0.7 0.8-2/20 3.9 Stamped Steel Zinc Plated Clamp On Service Entrance Heads NM / SE CABLE Service entrance caps are used as a connecting point in an overhead service entrance and can be mounted on threaded or unthreaded Rigid Conduit, IMC or EMT Conduit. Clamp-On Type Phenolic Insulator with Multiple Holes Listed for Use in Wet Locations Aluminum Die-Cast Alüminyum Döküm Vidal Kablo Ba lant Aparat : Havai hat kablolar n n biraraya getirilip bir noktada toplanmas n sa lamak amac yla kullan l r. Diflli borular n ucuna da eklemeye uygundur. 80 7090-9 /2 2.2 2.22.93-0 24 8 7090-3 3/4 2.48 2. 2.20-0 24 82 709-8 2.7 2.8 2. - 2 0 83 70920-2 /4 3.2 2.90 2.98-2 4 84 7092-7 /2 3.7 3.68 3.8-3 8 70930-2 4.34.28 4.6-8 866 7093-6 2 /2.64.2.20-4. 2877 70932-3 6.39 6.2.26-7 2888 7094-3 /2 6.82 6.8 7.6-6. 2899 7090-9 4 7.6 6.8 7.2-6. E2487 LR792 UL 4B CSA C22.2 No. 8 NEC Articles 34, 346 & 348 Threaded Service Entrance Heads NM / SE CABLE Service entrance caps are used as a connecting point in an overhead service entrance and can be mounted on threaded Rigid Conduit and IMC. Threaded Type Phenolic Insulator with Multiple Holes Listed for Use in Wet Locations Alüminyum Döküm Diflli Kablo Ba lant Aparat : Havai hat kablolar n n biraraya getirilip tek bir noktada toplanmas n sa lamak amac yla kullan l r. Diflli borular n ucuna eklemeye de uygundur. 860 0860- /2 0.97 2.9 2.04 - /0 86 086-2 3/4.6 2.4 2.3 - /2 8.8 862 0862-9. 2.83 2.4-0 4.8 863 0863-6 /4.89 2.89 3.00-0.2 8464 0864-3 /2 2.6 3. 3.20-0.2 86 086-0 2 2.70 4.36 4.8-7.7 E2487 LR792 Aluminum Die-Cast UL 4B CSA C22.2 No. 8 NEC Articles 34, 346 & 348 B 39
Service Entrance Cable Connectors/Kablo Rakorlar ve Aksesuarlar Service Entrance Mast Heads NM / SE CABLE Catalog UPC No Pipe Head Nominal Dimensions Pcs/ Ctn/Case Case Number 0-87 Size Size A B C Unit Qty/Qty Wt. Service entrance caps are used as a connecting point in an overhead service entrance and can be mounted on threaded or unthreaded Rigid Conduit, IMC or EMT Conduit. Slip Fit Phenolic Insulator with Multiple Holes Listed for Use in Wet Locations 9366 09366-0 2 /4 2.66 3.72 3.4-4 3 9367 09367-7 2 /2 /4 3.28 4.0 3.08-2 2 9368 09368-4 2 /2 2 3.2 4.7 4.20-2 2 E2487 LR792 UL 4B CSA C22.2 No. 8 NEC Articles 34, 346 & 348 Aluminum Die-Cast Kablo Sabitleme Aparat : Havai hat kablolar n n biraraya getirilip tek bir noktada toplanmas n sa lamak amac yla kullan l r. Diflli borular n ucuna eklemeye de uygundur. Oval Service Cable Heads NM / SE CABLE Die-cast oval service entrance caps are used as a connecting point in an overhead service entrance for SEU Cable. 9364 09364-6 3#8-3# 3.47.90 2.80 -.4 9364 0936-3 3/0-3#4/0 4.90 2.90 4.30-3.3 E40 LR792 UL 4B CSA C22.2 No. 8 NEC Articles 34, 346 & 348 Removable Cap 2-Piece Phenolic Insulator Listed for Use in Wet Locations Aluminum Die-Cast Oval Kablo Sabitleme Kroflesi : UL/NEC tip SEU Havai hat kablolar n n bir noktada düzenlenmesini sa lar. Hareketli kapa sayesinde kullan m kolayl sa lar. B 40
PVC Service Entrance Heads Catalog Number CONDUIT FITTINGS Service Entrance Cable Connectors/Kablo Rakorlar ve Aksesuarlar NM / SE CABLE Nominal Dimension Box Size A B C D E F G* H J Qty. Service entrance caps are used as a connecting point in an overhead service entrance and can be mounted on threaded or unthreaded Rigid, IMC, PVC or EMT Conduit. For Rigid, IMC, PVC & EMT (edeptor sleeve included) Supplied with screw and nut Rigid, weather-resistant design Acts as an insulator of high dielectric strength Meets UL & CSA specifications 7200 /2 2 2.78..968 0.687 0.937 0.8 2.609 0.32 2 720 3/4 2.406 2.296.78 2.234 0.82 0.937.06.2 0.437 2 7202 2.406 2.296.968 2.234 0.82.2.33.32 0.437 20 7203 /4 3.03 4.03 2.343 2.66 0.87.093.67.89 0.3 0 7204 /2 2.406 2.296.968 2.234 0.82.2.33.32 0.437 0 720 2 3.03 4.03 2.343 2.66 0.87.093.67.89 0.3 Plastic E687 Oval Kablo Sabitleme Kroflesi : Havai hat kablolar n n bir noktada düzenlenmesi amac yla kullan l r. Hareketli kapa sayesinde kullan m kolayl sa lar. IMC, Rigid, PVC ve EMT borularla kullanmaya uygundur. *Dimension G conforms to UL specs for metallic conduit. Adapter sleeve included for EMT. PVC Oval Service Cable Heads NM / SE CABLE Catalog Number UPC No Nominal Dimension Box 0-87 Size A B C D E F G Qty. PVC oval service entrance caps are used as a connecting point in an overhead service entrance for SEU Cable. 7206 07206- #8, 6, 4, 2 2 2.78.343.2 0.687 0.3.968 30 7207 07207-8 #0,00 3.03 4.03.7.37.2 0.687 2.87 0 7208 07208- #000, 0000 3.03 4.03 2.2.62.2 0.687 2.87 0 Accommodates 3-conductor No.8 AWG to 3-conductor No. 0000 AWG cables. Supplied with screw and nut Rigid, weather-resistant meterial Galvanized back plate for easy installation Meets UL specifications Plastic E3680 Oval Kablo Sabitleme Kroflesi : Havai hat kablolar n n bir noktada düzenlenmesikablolar n n birbirine eklenmesi amac yla kullan l r. Hareketli kapa sayesinde kullan m kolayl sa lar. B 4
Service Entrance Cable Connectors/Kablo Rakorlar ve Aksesuarlar 2-Piece Connectors NM / SE CABLE Piece clamp type connectors are usedto terminate one or more Nonmetallic Sheathed Cables to a knock-out in a dry location box or enclosure. Also used in old work locations. No Locknut Required Butterfly Style 924 0924-8 /2.32 0.9 0.6-00/000.0 9246 09246-3/4 -.7.2 0.76-0/00 39. 9247 09247-2 /4 2.2.63 0.76-00/000.0 9248 09248-9 /4 2.0.97 0.79-0/00 39. Steel ki Parçal Çelik Sabitleme Kroflesi : PVC kapl kablolar n pano ya da kutu girifllerinde sabitlenmesi için kullan l r. Service Cable Sill Plates NM / SE CABLE Catalog UPC No Nominal Dimension Box Number 0-87 A B C D E F G* H I Qty. 720 0720-8 2.87 0.968 0.70 3.093.406.093 2.968 0.078 2 0/00 Sill plates are used in conjunction with sealing compound to protect service entrance cable and to cover the hole where t enters the dwelling. Covers service cable where it bends to enter the building for an attractive finish May be used on all cable sizes from three #4 to three #0 Unaffected by seasonal temperature extremes Girifl Plakas : fiebeke kablolar n n geçti i deliklerde üzerini kapatmak ve d fl etkenlerden korumak için kullan l r. PVC Service Entrance Ells Type SLB - Aluminum Conduit Entrance Ells Service entrance ells are used to gain access to the interior of a raceway for wire pulling, inspection and maintenance. Listed for Use in Wet Location Aluminum Die-Cast Alüminyum Döküm Kondulet : Kablo çekmede ve kablolardan ek almakta kullan l r. Vidal kapa sayesinde kablo ek yerlerine müdahaleyi ve bak m kolaylaflt r r. Cover, gasket & screw included, for rigid conduit Catalog Number BWF# Unit UPC Conduit Description Case Case 0-87 Size Type Color Qty. Weight 00 700- /2 SLB Threaded Grey 38 8 0 700-3/4 SLB Threaded Grey 36 8 02 70-0 SLB Threaded Grey 2 6 03 7020-4 -/4 SLB Threaded Grey 2. 04 702-9 -/2 SLB Threaded Grey 0 0 0 7030-3 2 SLB Threaded Grey 4. 03-XL 703-2 -/4 XLSLB Threaded Grey 6 0-XL 7040-6 2 XLSLB Threaded Grey 4 E2488 LR792 UL 4B CSA C22.2 No. 8 NEMA FB- NEC Articles 338 B 42
Heavy Duty Porcelain Wireholders NM / SE CABLE CONDUIT FITTINGS Service Entrance Cable Connectors/Kablo Rakorlar ve Aksesuarlar Number 0-387 Size A B C Unit Qty/Qty Wt. 700 0700 0 2 /4 Lag.26.4 2.0-0 3. Porcelain wireholders are used in overhead services to support and secure incoming service entrance wires prior to entrance. Reinforced Porselen Kablo Tutucu : Havai hat kablolar n n sabitlenmesinde, tesisat kablolar n n girifllerinden önce güvenli bir flekilde sabitlenmesinde kullan l r. Porcelain Steel Adjustable Wireholders NM / SE CABLE Catalog UPC No Nominal Dimensions Pcs/ Ctn/Case Case Number 0-387 A B C Unit Qty/Qty Wt. Porcelain wireholders are used in overhead services to support and secure incoming service entrance wires prior to entrance. Clamp-On Mounts Below Service Entrance Cap 703 0703-2.80.70 3.37-20 30.4 Ayanlanabilen Porselen Kablo Tutucu : Kablolar n girifllerden önce rigid hale gelmesi ve hasar görmeden çekilmesini sa lar, kablo kesitlerine göre ayarlanabilir. Porcelain Steel Standard Porcelain Wireholders NM / SE CABLE Porcelain wireholders are used in overhead services to support and secure incoming service entrance wires prior to entrance. Porcelain Steel Universal Conduit Supports Number 0-387 Size A B C Unit Qty/Qty Wt. 70 070-0 -/6 3.88.44 2.3-0/000 28.0 706 0706-2 2-/4 4.80.9 2.64-0 30. Standart Porselen Kablo Tutucu : Havai hat kablolar n n sabitlenmesinde, tesisat kablolar n n girifllerinden önce güvenli bir flekilde sabitlenmesinde kullan l r. NM / SE CABLE Number 0-387 Size A B C Unit Qty/Qty Wt. Conduit supports are used to secure Service Entrance Conduit to the outside surface of a building /2 x 0 Stud Bolt Steel 709 0709-3 /4-3.36 4.0 0. - 20 7.7 Universal Çelik Boru Deste i : Kablolar n boru ile tafl nmas esnas nda borunun yüzeye sabitlenmesinde kullan l r. B 43
Service Entrance Cable Connectors/Kablo Rakorlar ve Aksesuarlar Clamp Type Connectors (NM Sheathed) Clamp Type Connectors (Oval Type SE) NM / SE CABLE 8470 08470-3/8" 0.80.7 0.39-00/000 47.8 847 0847-2 3/4" 0.94.67 0.42-0/00 44. 8472 08472-9 ".2.9 0.44-2/20 34.9 8473 08473-6 /4" 2.2.3 0.60-0/00 28. 8474 08474-3 /2" 2.87.33 0.60 - /0 9.0 847 0847-0 2" 3.0.7 0.74-0/40 2. Clamp type connectors are used to terminate Nonmetallic Sheathed and Oval Type SE or USE Cables to a knock-out in a dry location box or enclosure. UL Listed Locknut Male Hub Threads NPS E23494 / E40 UL 4B CSA C22.2 No. 8 NEMA FB- NEC Articles 336 & 338 LR792 Zamak Kablo Sabitleme Kroflesi : UL/NEC tip NM ve Oval tip SE ya da USE kablolar n n pano ve kutu girifllerinde sabitlenmesinde kullan l r. Trade Size For Cable Sizes 3/8" For one or two 4-2 to 2-2 Nonmetallic Sheathed Cables or one 0.29" to 0.4" diameter Flexible Cord. 3/4" For 0-3 to 8-2 Nonmetallic Sheathed and 8-3 to 4-3 Oval Service Entrance Cable and 8-3 to 6-3 Round Service Entrance Cable. " For 0-3 to 4-3 Nonmetallic Sheathed and 6-3 to 4-3 Oval Service Entrance Cable and 6-3 to 2-3 Round Service Entrance Cable /4" 4-3 to 2-3 Nonmetallic Sheathed and.9 Service Entrance Cable. /2" For.48 Service Entrance Cable. Roof Flashings NM / SE CABLE Catalog UPC No Trade Base Ctn/Case Case Number 0-87 Size Size Qty/Qty Wt. 79* 079-4 /2",2",3" 8 7/8"x 3/4" 0 0.0 720 0720-0 4" 8 7/8"x 3/4" 0 0.0 Roof flashings are used to provide a watertight seal in overhead services where the conduit mast penetrates the roofs surface. *Indicates Combo unit that can be used for all 3 sizes. Neoprene Boru Cephe Girifli : Havai hat kablolar n n boru içerisinde çat yüzeyinden güvenle girifl yapmas n sa lar. Contas sayesinde s v s zd rmazd r. B 44
Service Entrance Cable Connectors/Kablo Rakorlar ve Aksesuarlar Plastic Nonmetallic Cable Connectors NM / SE CABLE Catalog UPC No Trade Ctn/Case Case Number 0-87 Size Qty/Qty Wt. 77 077-0 3/8 -/2 00/000 7.0 Plastic nonmetallic cable connectors are used to terminate Nonmetallic Sheathed Cable to knockout in a dry location box or enclosure. Snap-In One Piece Construction Wide Variety of Cable Configurations Plastic Trade Size One Cable Two Cables 3/8" () 4/2-0/2 (2) 4/2-0/2 () 4/3-0-3 () 4/2 & 2/2 () 4/2 & 0/2 () 2/2 & 0/2 Plastik Kablo Girifl Aparat : Hassas kablolar n pano ve kutularda sonland r lmas nda kullan l r. Plastic Nonmetallic Cable Connectors NM / SE CABLE Number 0-87 Size A B C D E Qty/Qty Wt. 78 078-7 /2.34 2.42.834.883.82 0/20 8. Plastic nonmetallic cable connectors are used to terminate Nonmetallic Sheathed Cable or Flexible Cord to knockout in a dry location box or enclosure. Snap-In One Piece Construction Wide Variety of Cable Configurations Plastic Plastik Kablo Girifl Aparat : Hassas ve flexible kablolar n pano ve kutularda sonland r lmas nda kullan l r. Accommodates one or two 4-2, 4-3 and 2-2 cables, one 2-3, 0-2 and 0-3 cable, and one or two.300 inch or.600 inch diameter cords Push-in design with a captive lock wedge that secures cable with a single squeeze from standard electrician s pliers Excellent insulation, superior strain relief Sized to fit /2 inch (2.70mm) knockout size B 4
CONDUIT HANGERS Boru Ask Aparatlar Conduit Hanger W / Nut & Bolt Conduit hangers are used to secure and suspend EMT, Rigid, IMC and PVC Conduits from overhead supports. With Carriage Bolt and Nut Attached Stamped Steel Finish: Zinc Plated E86443 W /O Nut & Bolt LR0469 Vidal Boru Kroflesi : Metal ve PVC borular n tijle as lmas nda kullan l r. Civata ve somun dahil veya hariç siparifl edilebilir. 940 0940-6 /2".9 0.7 0.70-0/00 38.6 94 094-3 3/4" 2.2 0.7 0.82-00 8.3 942 0942-0 " 2.3 0.86 0.93-00 0.0 942-E 09428- /4" 2.72 0.86 0.98-00 2.2 943 0943-7 /2" 3.0 0.86.03-00 3. 94 094-2" 3.3 0.96.0-00 8.9 946 0946-8 2 /2" 4.0 0.96.2-0 0.7 947 0947-3" 4.60.8.2-2 7. 948 0948-2 3 /2".3.8.2-0 4.6 949 0949-9 4".3.8.2-0 4.6 9440 09440-7 /2".9 0.7 0.70-0/00 38.6 944 0944-4 3/4" 2.2 0.7 0.82-00 8.3 9442 09442- " 2.3 0.86 0.93-00 0.0 9442-E 09427-8 /4" 2.72 0.86 0.98-00 2.2 9443 09443-8 /2" 3.0 0.86.03-00 3. 944 0944-2 2" 3.3 0.96.0-00 8.9 9446 09446-9 2 /2" 4.0 0.96.2-0 0.7 9447 09447-6 3" 4.60.8.2-2 7. 9448 09448-3 3 /2".3.8.2-0 4.6 9449 09449-0 4".3.8.2-0 4.6 Type UBC Right Angle Type UPC Parallel Type UEC EdgeType Designed to secura rigid, IMC or EMT across, parallel or perpendicular to beam, channel and angle supports. Boru Ask Aparat : Elektrik borular n n sabitlenmesinde ve desteklenmesinde kullan lan çelik ba lant elemanlar d r. Her türlü metal ve plastik borunun tava, kirifl, kablo tavas ve benzeri yap lara montaj nda kullan l r. Features: * Easily installed * Capable of withstanding heavy loads Material All components are Malleable iron except nuts and bolts which are steel, Finish: Clamp - Hot dipped Galvanized Hardware - Mechanically Galvanized Catalog Number 90 UBC-0G UBC-7G UBC-00G UBC-2G UBC-0G UBC-200G UBC-20G UBC-300G UBC-30G UBC-400G UBC-00G UBC-600G Trade Size /2 3 /4 2 2 3 3 4 6 /4 /2 /2 /2 Catalog Number Parallel UPC-0G UPC-7G UPC-00G UPC-2G UPC-0G UPC-200G UPC-20G UPC-300G UPC-30G UPC-400G Note: Edge type UEC used for rigid conduit only. Catalog Number UEC-0G UEC-7G UEC-00G UEC-2G UEC-0G UEC-200G UEC-20G UEC-300G 90º T P UBC-G KÖfiEL T P UEC-G PARALEL T P UPC-G Type U Conduit U-Bolts Catalog Number Trade Size Dimensions ( nches) A B C D Thread Size Features: * 2 hex nuts Material Steel Finish: Mechanically Galvanized Çelik U-Civata : Borular n muhtelif yüzeylere sabitlenmesinde kullan l r. U-0SG U-7SG U-00SG U-2SG U-0SG U-200SG U-20SG U-300SG U-30SG U-400SG U-00SG U-600SG /2 3 /4 /4 /2 2 2 /2 3 3 /2 4 6 /6 3 /6 2 3 /2 /2 /4-20 /8 7 /6 2 /2 /2 /4-20 7 /6 3 /4 2 3 /6 /2 /6-8 2 3 /4 2 /6 2 /6 3 3 /4 /2 /2 /2 /6-8 /6-8 2 /2 2 7 /8 4 3 /4 3 /8-6 3 3 3 /8 4 /2 3 /4 3 /8-6 3 /8 4 /4 3 /4 3 /8-6 4 /8 4 /2 /6 3 /4 3 /8-6 4 /8 6 /4 3 /4 3 /8-6 /8 6 7 3 /8 3 /4 3 /8-6 6 /6 7 /6 8 3 /8 3 /8-6 B A D C B 46
CONDUIT HANGERS Boru Ask Aparatlar Type CTC CABLE TRAY CLAMPS For connecting and grounding rigid conduit, IMC, EMT to trays. Kablo Tavas Ba lant Eleman : Diflli ve diflsiz borular n kablo tavas na ba lant s ve topraklaman n devam n n sa lanmas nda kullan l r. Features: * Fast installation, low product cost * Strength, design, continuity Material/Finish: Malleable Iron/Mechanically Galvanized U - Bolts and Nut: Steel / Mechanically Galvanized Catalog Number CTC-007 CTC-02 CTC-0 CTC-200 CTC-20 CTC-300 CTC-30 CTC-30 Trade Size U-BOLT Nut 3 /2 - /4 /4-20 - /4 /6-8 3 /2 /6-8 3 2 /8-6 3 2 /2 /8-6 3 3 /8-6 3 3 /2 /8-6 3 4 /8-6 Third Party UL Listed:E-24264 W 2 2 3 4 6 /4 7 /8 7 /8 /2 /8 /8 /8 2 2 3 4 4 6 L T U /4 /4 /2 /2 /8 /2 /4 /4 3 /8 3 /8 3 /8 3 /8 3 /8 3 /8 CSA Certified 979 for rigid and EMT only 2 3 3 4 4 6 /2 /4 /2 /2 /4 3 /4 /4 TORK-KG 27 2 2 86 86 86 86 86 CTC-0 & CTC-02 / 2 - / 4 Kablo Tavas na Dik. T L U Type IS BEAM CLAMPS Provides support for conduit hanging systems. Mengene: Borular n ask l olarak tafl nmas nda kullan lan parçad r. Material: Malleable Iron clamp Steel Screw, case hardened Finish: Clamp - Hot Dip Galvanized Screw - Zinc Electroplated Catalog Number IS-00 IS-09 IS-0 IS-02 IS-03 Hole Size A B C D E /4-20 0-24 /6-8 3 /6-6 /2-3 /6 /6 /6 /8 7 /8 7 / /8 3 /8 /6 2 2 /8 /8 3 /6 /6 /4 2 2 /2 /8 MAX. Load Ibs 33 33 2 70 900 D E A - Tapped Holes (2) Load C B - Jaw Opening Strut Provides support for conduit hanging systems. Catalog Number PS-0 0PG-HS PS-20 0PG-HS Dimensions 4 x 22 x 300 mm 4 x 4 x 300 mm C Profil Tij veya farkl desteklerle borular n dikeyde ve yatayda kroflelerle sabitlenerek, tafl nmas nda kullan l r. / 8 3/ 6 7/ 8 4 Gauge / 8 Pipe&Conduit Clamp Provides conduits to fixing struts. Boru Kroflesi Borular C profile sabitlemede kullan l r. Catalog Number STR-00 STR-07 STR-00 STR-2 STR-0 STR-200 STR-20 STR-300 STR-30 STR-400 Trade Size /2 3/4 2 2 3 3 4 /4 /2 /2 /2 Thickness.060.07.07.07.0.0.0.0.2.2 Load. LBS. 400 600 600 600 800 800 800 800 000 000 00 piece Weight (kg) 7 7 9 3 8 2 28 30 A B 47
CONDUIT HANGERS Boru Ask Aparatlar B 3 / 4 " T all 2 Ga. SH Channel 9/ 6 " x 7/ 8 "slots 2" on centers TN Series B2 2 7/ 6 " T all 2 Ga. B22 / 8 " T all 2 Ga. 4 Ga. 6 Ga. B22TH Channel 9/ 6 " holes 7/ 8 " on centers B32 3/ 8 " T all 2 Ga. H 7/ 8 Channel 9/ 6 " holes 7/ 8 " on centers NWO Series HHCS Series LW Series FW Series HN Series B0 B07-22A B0 Basic Channel / 8 " Wide Sections, Combinations & Hole Patter ns B202D B07 B29 B4 B26 Series B2 3 / 6 " T all 2 Ga. 4 Ga. 6 Ga. B844W A Channel KO6 Channel 7/ 8 " dia. knockout 6" on centers STN Series B6, B66 B34 B33 B47-B2 B4 B62-B6 B72 X Channel S Channel 3/ 32 " x 3"slots 4" on centers Plain Channel Dura-Gr een Channel Pr e-galvanized Channel HDGAF Channel Special Painted Channel PVC Coated Channel Aluminum Channel B02 B9 N Series Channel Nuts & Hardware B04 Strut Fittings B272 B0 EZ Twirl B24 ATR Series B32 B-B6 B68 General Information (Channel & Fittings) Applications: B-Line Systems channel is a basic structural member of the channel framing system. Use of the channel along with the appropriate fittings and attachments permit the rapid and economical construction of a virtually unlimited variety of rigid metal support structures. Channel sections are roll for med from strip steel coils while fittings are made from either steel coils or sheet. Refer to page of the B-Line Strut Systems catalog for Channel Selection Table, pages 6-37 for Channel Load Data and pages 4-3 for Technical Data. Other sizing charts for conduit, pipe and tubing as well as threaded rod load charts are shown on pages 207-2 of the Strut Systems catalog. B-Line's standard roll formed channels are made from Pre Galvanized steel conforming to ASTM A63 SS, Grade33 G90 (.4 oz. zinc/ft.2). Plain finish channels are roll formed from hot-rolled, pickled and oiled steel conforming to ASTM A70, Grade 33. Certain sections are available able in Stainless Steel Type 304 & 36 (consult factory). Aluminum alloy 6063-T6 is used to extrude several channel sections and combination sections (consult factory). Finishes:B-Line's standard finishes on channels are Dura-Green Epoxy and Pre Galvanized (as shown above) while standard finishes for fittings are Dura- Green Epoxy and Zinc Plated. Plain finish is also available. (HDGAF) Hot- Dipped Galvanized After Fabrication is available on both channel and fittings (not recommended on threaded items) and conforms to one of the following applicable specifications: ASTMA23 or ASTM A3. Electro Galvanized Zinc (ZNPLT), ASTM B633, is available on most fittings and can be placed on channelsper customer order PVC coated and special paint colors are available on both channel and fittings per customer order (pleaseconsult factory). See B-Line's Strut Systems (SS99) and Pipe Hangers & Supports (PH-00) Engineering Catalogs for more product information. Many products comply with the following: Manufacturers Standardization Society Specifications MSS-SP-8 and MSS- SP-69. Federal Specification WW-H-7e. Underwriters Laboratories Surface Metal Raceways. ASTM B633. ASTM A63 SS, Grade 33 G90 ASTM A70, Grade 33 B 48
CONDUIT HANGERS Boru Ask Aparatlar Strut Fittings B279 B280SQ B28FL B63 B376 B203-B206 B220-B223 B822 Brackets B409 Series B297 Series B494 Series B9 Series B3063 B3064 B3066 Concrete Inserts - Continuous & Spot B22I, B32I, B2I B20 B203 B200 B20-B208 B304 B309 B3020 Beam Clamps B3, B3L B32 B3362 B3036L thru B303-B309, B32 B303-3/8 B3034 B336 Series B3367 B304 B329 thru B3298 B30 B2 B7-J4-J2 B70 Series B44-22, B44-22A Upper Attachments B3087 B3060 B3080 B308 B399 B3062 B3070 B3083 B 49
CONDUIT HANGERS Boru Ask Aparatlar Pipe Clamps & Hangers B2000 Series B2207-B223 B260 B2400 B347A & B B3373 B340 B344 Vibra-Cushion BVT Series Vibra-Clamps B39 B400 B370 B374 B3690 B3690C B3690F B398H B37 B300 B300F B306 & B306V B386 B390 B39 Rollers, Guides & Saddles B28 B379 B34 B37SL B326 B30 B322A B3088 B3090 B3088T B3092 B328 - B3287 B3 B32 B3380 thru B3384 B360 - B36 B389 - B3897 B326 Seismic Fittings B33 Series B633 Series B634 SC228 SC- UB B 0
CONDUIT HANGERS Boru Ask Aparatlar Pipe Hangers & Supports Accessories B320 B320X B3203 B388 B320 B3202 B3234 B323 B3200 Electrical Accessories B66 Series B390S B46 B6S B27, B27P B392 Series B766 B768 Series B79 B4033 Series Maple Clamps B4060 thru B4093 Por celain Clamps Vibraatol Accessories CNP VRP HML T/HMT HSL/HS HESL/HES ANH HMLE/HME B
CONDUIT HANGERS Boru Ask Aparatlar Metal Framing Electrical Applications Lighting Fixture Supports Raceway Systems Trapeze Hangers Pipe & Conduit Supports Cable Tray Supports Beam Adjustments B-Line s Metal Framing system provides an economical solution for electrical, mechanical and industrial supports with an unlimited variety of applications in the construction industry. Metal Framing Mechanical Applications Piping Racks Tunnel Pipe Stanchions Concrete Inserts Beam Attachments Pipe Risers Metal Framing Industrial Applications Racks and Shelving Partitions Production Line Supports Trolley Systems Wall Framing B 2