Yeditepe Üniversitesi Diş Hekimliği Fakültesi Dergisi. 7tepe Klinik Dergisi. 7tepeklinik. Sahibi. Yayın Kurulu. Editör. Yardımcı Editörler



Benzer belgeler
DOKTORA TEZİ PROTETİK DİŞ TEDAVİSİ ANABİLİM DALI

SERVİKAL YETMEZİĞİNDE MCDONALDS VE MODDIFIYE ŞIRODKAR SERKLAJ YÖNTEMLERININ KARŞILAŞTIRILMASI

First Stage of an Automated Content-Based Citation Analysis Study: Detection of Citation Sentences

7tepeklinik ÖZGÜN ARAŞTIRMA

ÖZGEÇMİŞ. Derece Alan Üniversite Yıl. Pedodonti Anabilim Dalı

Görevler: Görev Unvanı Görev Yeri Yıl Dok. Öğr. Gazi Üniversitesi Diş Hekimliği Fakültesi

ÖZGEÇMİŞ VE ESERLER LİSTESİ

I N D E X. vii. Yücel Yılmaz, İlknur Tosun. Acta Odontol Turc 2013;30(3):123-7 (32 ref) TK

A UNIFIED APPROACH IN GPS ACCURACY DETERMINATION STUDIES

ÖZGEÇMİŞ. Derece Alan Üniversite Yıl

ÖZGEÇMİŞ. 3. AN Dincer, O Er, BC Canakci: Evaluation of apically extruded debris during root canal. 1. Adı Soyadı : Asiye Nur Dinçer

daha çok göz önünde bulundurulabilir. Öğrencilerin dile karşı daha olumlu bir tutum geliştirmeleri ve daha homojen gruplar ile dersler yürütülebilir.

Postlar endodontik tedavi sonrası dişlerde görülen aşırı madde kaybının

THE IMPACT OF AUTONOMOUS LEARNING ON GRADUATE STUDENTS PROFICIENCY LEVEL IN FOREIGN LANGUAGE LEARNING ABSTRACT

ÇİNKO KATKILI ANTİBAKTERİYEL ÖZELLİKTE HİDROKSİAPATİT ÜRETİMİ VE KARAKTERİZASYONU

KANSER HASTALARINDA ANKSİYETE VE DEPRESYON BELİRTİLERİNİN DEĞERLENDİRİLMESİ UZMANLIK TEZİ. Dr. Levent ŞAHİN

Yüz Tanımaya Dayalı Uygulamalar. (Özet)

Epiphany nin Farklı Kanal Dolgu Materyalleri ile Kök Kanalına Bağlanma Dayanımı

T.C. SÜLEYMAN DEMİREL ÜNİVERSİTESİ FEN BİLİMLERİ ENSTİTÜSÜ ISPARTA İLİ KİRAZ İHRACATININ ANALİZİ

A4. Özsezer E, Inan U, Aydın U. In vivo evaluation of ProPex electronic apex locator. J Endod 2007; 33(8):

Farklı irrigasyon solüsyonlarının MTA Fillapex kanal patının bağlanma dayanımı üzerine etkisi

Postmenopozal Kadınlarda Vücut Kitle İndeksinin Kemik Mineral Yoğunluğuna Etkisi

ULUSLARARASI HAKEMLİ DERGİLERDE YAYIMLANAN MAKALELER. 1- Guler AU, Kurt S, Kulunk T. Effects of various finishing procedures on the staining of

T.C. TRAKYA ÜNİVERSİTESİ FEN BİLİMLERİ ENSTİTÜSÜ AŞIRI PLASTİK DEFORMASYON METOTLARININ ALÜMİNYUM ALAŞIMLARININ MEKANİK ÖZELLİKLERİNE ETKİSİ

PRELIMINARY REPORT. 19/09/2012 KAHRAMANMARAŞ PAZARCIK EARTHQUAKE (SOUTHEAST TURKEY) Ml=5.1.

İŞLETMELERDE KURUMSAL İMAJ VE OLUŞUMUNDAKİ ANA ETKENLER

zeytinist

ELDAŞ Elektrik Elektronik Sanayi ve Tic.A.Ş.

NANO KURġUN ÜRETĠMĠ VE KARAKTERĠZASYONU

KANAL DENTİNİ VE FİBERLE GÜÇLENDİRİLMİŞ KOMPOZİT POST YÜZEYİNE UYGULANAN FARKLI YÜZEY İŞLEMLERİNİN POST- DENTİN BAĞLANTISINA ETKİSİNİN İNCELENMESİ

Tekirdağ&Ziraat&Fakültesi&Dergisi&

Derece Alan Üniversite Yıl Lisans Diş Hekimliği Ankara Üniversitesi 1979 Y. Lisans Doktora Protez Ankara Üniversitesi 1983

TÜRKiYE'DEKi ÖZEL SAGLIK VE SPOR MERKEZLERiNDE ÇALIŞAN PERSONELiN

g Na2HPO4.12H2O alınır, 500mL lik balonjojede hacim tamamlanır.

ÇEVRESEL TEST HİZMETLERİ 2.ENVIRONMENTAL TESTS

KOCAELİ ÜNİVERSİTESİ Ford Otosan İhsaniye Otomotiv MYO

Performans Tabloları Yalınkat Camlar

: Fulya Sokak Mehmetçik Cad. Gündüz Apt. No. 29 D5 Şişli İstanbul. : : eeliguzeloglu@hotmail.com

Unlike analytical solutions, numerical methods have an error range. In addition to this

LANDE DYNAcenter Server Cabinet W600 X D1000 MECHANICAL TESTS REPORT

BOĞAZİÇİ UNIVERSITY KANDİLLİ OBSERVATORY and EARTHQUAKE RESEARCH INSTITUTE GEOMAGNETISM LABORATORY

FiberSite ve RelyX Fiber Post Sistemlerinin Kök Kanal Dentinine Push-out Bağlantı Dayanımlarının Karşılaştırılması

Selçuk Üniversitesi Ziraat Fakultesi Bahçe Bitkileri Bolumu Selçuklu/KONYA (Sorumlu Yazar)

Arýza Giderme. Troubleshooting

ÖZGEÇMİŞ Adı Soyadı: Ünvanı: Öğrenim Durumu: Derece Alan Üniversite Yıl

T.C. Hitit Üniversitesi. Sosyal Bilimler Enstitüsü. İşletme Anabilim Dalı

SBR331 Egzersiz Biyomekaniği

FİBER POST SİMANTASYONUNDA KULLANILAN SELF-ADEZİV REZİN SİMANLARIN MİKROSIZINTILARININ KARŞILAŞTIRILMASI

WEEK 11 CME323 NUMERIC ANALYSIS. Lect. Yasin ORTAKCI.

Argumentative Essay Nasıl Yazılır?

Dr.Dt. Ankara Üniversitesi Diş Hekimliği Fakültesi Endodonti Anabilim Dalı, Ankara, Türkiye **

Derece Bölüm Üniversite Yıl. Lisans Y. Lisans Diş Hekimliği Marmara Üniversitesi 2008

SELF-ETCH ADEZİVİN TEK KAT VEYA ÇOK KAT UYGULAMASININ MAKASLAMA DİRENCİ ÜZERİNE ETKİSİ

YRD. DOÇ. DR. EBRU HAZAR BODRUMLU

FIBER POST SIMANTASYONUNDA TÜKÜRÜK KONTAMINASYONUNUN BAĞLANMA DEĞERLERI ÜZERINE ETKISI

H48.33b FILTER DRIER SHELLS KARTUŞ KOVANLARI. H48.33b.54.1

Derece Alan Üniversite Yıl Lisans Yüksek Lisans Diş Hekimliği Fakültesi Ege Üniversitesi 2004 Doktora

MOZAİK SANATI ANTAKYA VE ZEUGMA MOZAİKLERİNİN RESİM ANALİZLERİ MEHMET ŞAHİN. YÜKSEK LİSANS TEZİ Resim Ana Sanat Dalı Danışman: Doç.

Prof.Dr. SENEM GÖKÇEN YİĞİT ÖZER

KULLANILAN MADDE TÜRÜNE GÖRE BAĞIMLILIK PROFİLİ DEĞİŞİKLİK GÖSTERİYOR MU? Kültegin Ögel, Figen Karadağ, Cüneyt Evren, Defne Tamar Gürol

ÖZGEÇMİŞ VE ESERLER LİSTESİ

A. ULUSLARARASI HAKEMLİ DERGİLERDE YAYINLANAN MAKALELER : SCI-Expanded, SSCI, AHCI indekslerine giren dergilerde yayınlanan makaleler:

ÖNSÖZ. Bayram NCE 2009 / Diyarbak r

ESERLER LİSTESİ. A2. Tunga, U. ve E. Bodrumlu, Assessment of the sealing ability of a new root canal obturation material, J Endod, 32, (2006).

KANSER HASTALARINDA PALYATİF BAKIM VE DESTEK SERVİSİNDE NARKOTİK ANALJEZİK KULLANIMI

24kV,630A Outdoor Switch Disconnector with Arc Quenching Chamber (ELBI) IEC IEC IEC 60129

ÖZGEÇMİŞ VE ESERLER LİSTESİ

YARASA VE ÇİFTLİK GÜBRESİNİN BAZI TOPRAK ÖZELLİKLERİ ve BUĞDAY BİTKİSİNİN VERİM PARAMETRELERİ ÜZERİNE ETKİSİ

ÖZET OTOMATİK KÖKLENDİRME SİSTEMİNDE ORTAM NEMİNİN SENSÖRLERLE HASSAS KONTROLÜ. Murat ÇAĞLAR

Güneş enerjisi kullanılarak sulama sistemleri için yeni bilgi tabanlı model

EGE UNIVERSITY ELECTRICAL AND ELECTRONICS ENGINEERING COMMUNICATION SYSTEM LABORATORY

Marble / Granite / Concrete / Asphalt

ÖZGEÇMİŞ. 1. Adı Soyadı: AYGÜL SEVDA ATALAY ONUR. İletişim Bilgileri:

ISSN: Yıl /Year: 2017 Cilt(Sayı)/Vol.(Issue): 1(Özel) Sayfa/Page: Araştırma Makalesi Research Article

4. HAFTA BLM323 SAYISAL ANALİZ. Okt. Yasin ORTAKCI.

T.C. İSTANBUL AYDIN ÜNİVERSİTESİ SOSYAL BİLİMLER ENSTİTÜSÜ BİREYSEL DEĞERLER İLE GİRİŞİMCİLİK EĞİLİMİ İLİŞKİSİ: İSTANBUL İLİNDE BİR ARAŞTIRMA

ÖZGEÇMİŞ VE ESERLER LİSTESİ

ESERLER A. ULUSLARARASI HAKEMLİ DERGİLERDE YAYIMLANAN MAKALELER. 1. Guler AU, Ceylan G, Özkoç O, Aydın M, Cengiz N. Prosthetic treatment of a

Prof.Dr. MUSA ŞAMİL AKYIL

Random Biopsilerin Kolposkopi Uygulamasında Yeri Vardır / Yoktur

Determinants of Education-Job Mismatch among University Graduates

Teşekkür. BOĞAZİÇİ UNIVERSITY KANDİLLİ OBSERVATORY and EARTHQUAKE RESEARCH INSTITUTE GEOMAGNETISM LABORATORY

Mitsubishi Electric Corporation. Number of Items

Okul Öncesi (5-6 Yaş) Cimnastik Çalışmasının Esneklik, Denge Ve Koordinasyon Üzerine Etkisi

PROPSET AYARLANABİLİR DİKME SİSTEMİ PROPSET ADJUSTABLE PROP SYSTEM

THE EFFECTS OF RAW MATERIAL, WEFT SETTING AND WEAVE ON THE BREAKING STRENGTH, ELONGATION AT BREAK AND TEAR STRENGTH OF UPHOLSTERY DOUBLE FABRICS

Diyabetik Ayakta Hiperbarik Oksijen Tedavisi

ÖZGEÇMİŞ. Derece Alan Üniversite Yıl

WEEK 4 BLM323 NUMERIC ANALYSIS. Okt. Yasin ORTAKCI.

Farklı post boylarının ve farklı siman kullanımının kron ile restore edilmiş dişlerin kırılma dayanımına etkisi *

PCC 6505 PROFILE CUTTING LINE

7tepeklinik. Lazer kullanımının kök kanal dentini üzerine uygulanan adezivlerin bağlanma dayanımı üzerine etkilerinin incelenmesi

KÖK KANAL TEDAVİSİNDE ER:YAG LAZERİN SMEAR TABAKASI ÜZERİNE ETKİSİ: SEM ÇALIŞMASI

ANALYSIS OF THE RELATIONSHIP BETWEEN LIFE SATISFACTION AND VALUE PREFERENCES OF THE INSTRUCTORS

ISSN: Yıl /Year: 2017 Cilt(Sayı)/Vol.(Issue): 1(Özel) Sayfa/Page: Araştırma Makalesi Research Article. Özet.

SICAKLIK VE ENTALP KONTROLLÜ SERBEST SO UTMA UYGULAMALARININ KAR ILA TIRILMASI

DOKUZ EYLUL UNIVERSITY FACULTY OF ENGINEERING OFFICE OF THE DEAN COURSE / MODULE / BLOCK DETAILS ACADEMIC YEAR / SEMESTER. Course Code: MAK 2029

Cases in the Turkish Language

HSS High Speed Steel SAW BLADES DAİRESEL TESTERELER

Sıcak Kesim ve Friksiyon Daire Testereler. Hot and Friction Circular Saw Blade

Transkript:

1 Yeditepe Üniversitesi Diş Hekimliği Fakültesi Dergisi 7tepe Klinik Dergisi Sahibi Yeditepe Üniversitesi Diş Hekimliği Fakültesi Adına Prof. Dr. R. Figen Kaptan, Dekan Editör Prof. Dr. İdil Dikbaş Yardımcı Editörler Doç. Dr. Ceyda Özçakır Tomruk Doç. Dr. Zeynep Özkurt Kayahan Doç. Dr. Hare Gürsoy Yayın Kurulu Prof. Dr. Bahar Eren Kuru (Yeditepe Üniversitesi) Prof. Dr. Bahar Sezer (Ege Üniversitesi) Prof. Dr. Baybora Kayahan (Okan Üniversitesi) Prof. Dr. Buket Aybar (İstanbul Üniversitesi) Prof. Dr. Cenk Haytaç (Çukurova Üniversitesi) Prof. Dr. Dilhan İlgüy (Yeditepe Üniversitesi) Prof. Dr. Ender Kazazoğlu (Yeditepe Üniversitesi) Prof. Dr. Fulya Özdemir (Yeditepe Üniversitesi) Prof. Dr. Gonca Çayır Keleş (Ondokuz Mayıs Üniversitesi) Prof. Dr. Jale Tanalp (Yeditepe Üniversitesi) Prof. Dr. Leyla Kuru (Marmara Üniversitesi) Prof. Dr. Mübin Soyman (Yeditepe Üniversitesi) Prof. Dr. Tamer Erdem (Okan Üniversitesi) Doç. Dr. Berkay Tolga Süer (GATA Haydarpaşa Eğitim Hastanesi) Doç. Dr. Didem Özdemir Özenen (Yeditepe Üniversitesi) Doç. Dr. Emre Özel (Kocaeli Üniversitesi) Doç. Dr. Hakan Akın (Cumhuriyet Üniversitesi) Doç. Dr. Hanefi Kurt (Medipol Üniversitesi) Doç. Dr. S. İlhan Ramoğlu (Bezmialem Vakıf Üniversitesi) Doç. Dr. Tamer Tüzüner (Karadeniz Teknik Üniversitesi) Yrd. Doç. Dr. Çiğdem Kaspar (Yeditepe Üniversitesi) ISSN: 1307-8593 BASKI: Ulusal Dijital Baskı Kopyalama Merkezi Kayışdağı Mh. Kayışdağı Cd. No: 225 34755 Ataşehir - İstanbul Pleksus Türk Medline veritabanında indeksli

2

3 İÇİNDEKİLER ÖZGÜN ARAŞTIRMALAR Özkurt-Kayahan Z, Yurdagüven H, Dikbaş İ, Kayahan MB, Kazazoğlu E, Soyman M. The short-term effect of sodium ascorbate irrigation on push-out bond strengths of fiber posts Sodyum askorbat irrigasyonunun fiber postların bağlanma kuvveti üzerindeki kısa süreli etkisi... 5 Aydoğdu A, Ballı U, Keskiner İ, Sağır S. Erbium-Doped Yttrium Aluminum Garnet (Er:Yag) lazerin periodontitisli kök yüzeylerinde neden olduğu morfolojik değişikliklerin taramalı elektron mikroskobu ile değerlendirilmesi Effect of Erbium-Doped Yttrium Aluminum Garnet (Er:Yag) laser on the morphology of periodontally diseased root surfaces with scanning electron microscopy... 15 DERLEMELER Abbasoğlu Z, Gürdoğan EB, Selvi Kuvvetli S. Süt azı hipomineralizasyonu Deciduous molar hypomineralization... 21 Barut G. Kök kanallarından kalsiyum hidroksit uzaklaştırılmasında kullanılan yıkama solüsyonu aktivasyon yöntemleri Different activation techniques for removal of calcium hydroxide paste from root canals... 27 OLGU SUNUMLARI Açikgöz M, Günbatan M, Yurtseven A, Ak G. Alveolar bone preservation by using highly porous bioabsorbable device before implantation: A case report İmplant öncesi yüksek poröziteli rezorbe olabilen aygıt kullanımı ile alveolar kemiği koruma: Bir olgu sunumu... 33 Cansız E, Atalay B, Akbaş E. Inferior alveolar nerve lateralization: A case report İnferior alveolar sinir lateralizasyonu: Bir olgu sunumu... 37 Yalçın GM, Yılmaz A, Cabbar F. Inferior alveolar nerve paresthesia related with a complex odontoma in the posterior mandible: A case report Posterior mandibuladaki kompleks odontomaya bağlı inferior alveolar sinir parestezisi: Bir olgu sunumu... 41

4

ORIGINAL ARTICLE 5 The short-term effect of sodium ascorbate irrigation on push-out bond strengths of fiber posts Sodyum askorbat irrigasyonunun fiber postların bağlanma kuvveti üzerindeki kısa süreli etkisi Assoc. Prof. Zeynep Özkurt-Kayahan Department of Prosthodontics, Yeditepe University, Faculty of Dentistry, Istanbul, Turkey. Assoc. Prof. Haktan Yurdagüven Department of Restorative Dentistry, Yeditepe University, Faculty of Dentistry, Istanbul, Turkey. Prof. İdil Dikbaş Department of Prosthodontics, Yeditepe University, Faculty of Dentistry, Istanbul, Turkey. Prof. Mehmet Baybora Kayahan Department of Endodontics, Okan University, Faculty of Dentistry, Istanbul, Turkey. Prof. Ender Kazazoğlu Department of Prosthodontics, Yeditepe University, Faculty of Dentistry, Istanbul, Turkey. Prof. Mübin Soyman Department of Restorative Dentistry, Yeditepe University, Faculty of Dentistry, Istanbul, Turkey. Received : 19 June 2015 Accepted : 20 September 2015 Corresponding author: Zeynep Özkurt-Kayahan Yeditepe University, Faculty of Dentistry Department of Prosthodontics, Bağdat cad. No: 238 34728, Goztepe, Istanbul, Turkey email: zeynepozkurt@hotmail.com SUMMARY Aim: The aim of this study was to evaluate the pushout bond strength of fiber posts to root canal dentin after irrigation of post spaces, prepared shortly after root canal filling. Materials and Methods: Thirty roots of maxillary central incisors and canines were divided into 3 groups (n=10) and irrigated with different solutions after post space preparations. In the first group that served as the control, only distilled water was used for irrigation. In the second group, 5.25% NaOCl, 17% EDTA and distilled water were used subsequently for irrigation. In the third group, 5.25% NaOCl, 17% EDTA and distilled water were used. Then, 10% sodium ascorbate was applied to root canal for 10 minutes. RelyX Fiber Posts were cemented with RelyX Unicem selfadhesive resin cement. Three slices from different root regions (coronal, middle, apical) were sectioned, and totally 90 slices were collected. The push-out test was conducted and the SEM analysis was performed to determine the failure modes. One-way ANOVA and Tukey HDS tests were used to analyze the data (p<0.05). Results: The mean bond strength was found as 8.64±3.73 MPa in the control group, 8.37±2.88 MPa in the second group and 9.94±2.94 MPa in the third group. There were no statistically significant differences between the bond strength values of the groups related to irrigation procedures and root regions (p>0.05). Conclusions: Sodium ascorbate application after post space preparation did not cause higher bond strength of fiber posts to dentin, compared to conventional NaOCl and EDTA irrigation. Keywords: Sodium ascorbate, bond strength, fiber post. ÖZET Amaç: Bu çalışmanın amacı, kanal dolgusunun hemen ardından hazırlanan post boşluklarının irrigasyonundan sonra, fiber postların kök kanal dentinine push-out bağlanma kuvvetinin değerlendirilmesidir. Gereç ve Yöntem: 30 adet tek kanallı üst kesici ve kanin dişleri 3 gruba ayrıldı (n:10). Kanal tedavileri tamamlandıktan ve post boşlukları hazırlandıktan sonra dişler farklı solüsyonlarla yıkandı. 1.gruptaki dişler distile suyla yıkandı ve kontrol grubu olarak belirlendi. 2.gruptaki dişler %5,25 NaOCl, %17 EDTA ve distile suyla yıkandı. 3.gruptaki dişler % 5,25NaOCl, %17 EDTA ve distile suyla yıkandı. Ardından, bu gruptaki dişlere 10 dk boyunca %10 sodyum askorbat solüsyonu uygulandı. RelyX fiber postlar RelyX Unicem self-adeziv rezin simanla yapıştırıldı. Köklerin kuronal, orta ve apikal olmak kaydıyla her bölümünden 3 adet kesit alındı ve toplamda 90 adet kesit elde edildi. Pushout bağlanma dayanımı testi ve kırık tiplerini belirlemek

6 The bond strengths of fiber posts amacıyla SEM analizi yapıldı. İstatistiksel analiz için one-way ANOVA ve Tukey HDS testleri kullanıldı (p<0.05). Bulgular: Ortalama bağlanma dayanımı değerleri kontrol grubunda 8,64±3,73 MPa, 2.grupta 8,37±2,88 MPa ve 3.grupta 9,94±2,94 MPa olarak bulundu. Kök bölgelerine ve kullanılan irrigasyon solüsyonlarına göre bağlanma dayanımı değerleri arasında anlamlı bir farklılık gözlenmedi (p>0.05). Sonuç: Post boşluğu hazırlandıktan sonra uygulanan sodyum askorbat solüsyonu, NaOCl ve EDTA ya kıyasla fiber postların dentine bağlanma kuvvetini arttırmamaktadır. Key words: Sodyum askorbat, bağlanma kuvveti, fiber post. INTRODUCTION Fiber-reinforced composite (FRC) posts have been used successfully in endodontically treated teeth because they have similar elastic modulus to dentin that leads to decrease in the incidence of root fracture (1), they do not cause metallic allergies and they provide good esthetics especially in visible areas (2). On the other hand, removal of a FRC post is easy in retreatment cases (3). FRC posts are cemented with adhesive resin cements. The success of FRC posts depends on the cementing agent and the success of the cementing procedure to root canal dentin (4). Debonding is considered as the main failure mode of FRC posts (5). Many factors may cause debonding. The dentin of endodontically treated teeth is generally contacted by mechanical instrumentation, irrigation, medication and temporary restoration. In a study conducted by Nikaido et al. (6), it was stated that the remnants of irrigation solution such as sodium hypochlorite (NaOCl) or hydrogen peroxide demonstrated negative effect on polymerization of the adhesive system, which caused reduction of bond strength. It has been suggested that this reduction might be caused by the damage of the organic matrix, mainly the collagen, leaving the mineralized surfaces of dentin by application of NaOCl (6). In addition, NaOCl breaks down to sodium chloride and oxygen. Oxygen from the chemical reaction causes strong inhibition of the interfacial polymerization of adhesive materials (7). Otherwise, there might be some reactive residual free-radicals in NaOCl treated dentin which might compete with the vinyl free radicals generated during light activation of the adhesive system. This results in premature chain termination and incomplete polymerization (8). To achieve adequate bond strength, 10% sodium ascorbate was introduced to apply on the NaOCl treated dentin and followed by water rinsing (8, 9). The sodium ascorbate is a reducing agent that interacts with oxygen, which is by-product of NaOCl by redox reaction (9). According to Vongphan et al. (10) application of 10% sodium ascorbate on NaOCl treated dentin (40.5 MPa) significantly increased the bond strength of single bond on etched dentin compared to NaOCl treatment (21 MPa). This finding was in agreement with the other studies (9, 11, 12). They found that additional treatment with ascorbic acid or neutral sodium ascorbate increased bond strengths of resin cements. Immediate restoration of endodontically treated teeth is of great significance both for clinicians and patients. This immediate approach may prevent microleakage (13). In addition, dental patients expect adequate esthetics and function shortly after the root canal treatment (14). Although it was indicated in a few studies (9-12) that sodium ascorbate irrigation restored the bond strength of resin cements, shortterm effect of sodium ascorbate on bond strengths of FRC posts to root canal dentin has not been evaluated yet. Thus, the aim of this study was (i) to evaluate the push-out bond strength of self-adhesive resin cement to dentin surfaces which were treated with different irrigates, (ii) to evaluate the effect of sodium ascorbate irrigate on the bond strength of FRC posts shortly after applying the conventional NaOCl and EDTA (ethylenediaminetetracetic acid) irrigates, and (iii) to determine the bond strength of FRC posts according to regional differences of the root dentin. The hypothesis tested was that, sodium ascorbate irrigation would increase the push-out bond strength of FRC posts shortly after the root canal treatment, reducing the negative effect of NaOCl irrigate used during instrumentation and post space preparation of the roots. MATERIALS AND METHODS Thirty human maxillary central incisors and canines extracted for periodontal reasons, with straight single root canals, free of cracks, caries, and fractures, and fully developed apices, were selected for this study. External debris was removed and they were stored in tymol solution for surface disinfection until use. The crown of each tooth was removed from the cemento-enamel junction with a 0.15 diamond-wafering blade (Buehler Ltd., Lake Bluff, IL, USA) with a slow speed saw (Buehler Ltd., Lake Bluff, IL, USA) under water cooling, to achieve a uniform length of 16 mm. The pulp tissue was removed with a barbed broach. Canal patency was determined by passing a size 10 K-file (Dentsply Maillefer, Ballaigues, Switzerland) through the apical foramen. Canal working lengths were established 1 mm short of the apical foramen and the step-back technique was used for canal instrumentation. The 30 roots were randomly assigned to 3 groups (n=10). In group 1, which served as the control, root

7 canals were copiously irrigated with distilled water during shaping procedure. In group 2 and group 3, root canals were copiously irrigated with 5.25% NaOCl between the instruments. At the end of shaping procedure, canals were thoroughly rinsed using 17% aqueous EDTA. Distilled water was the final irrigant. Following the irrigation, the canals were completely dried with absorbent paper points (Dentsply Maillefer, Ballaigues, Switzerland). Then the canals were obturated with cold lateral condensation technique. AHPlus (De Trey-Dentsply, Konstanz, Germany) was the sealer. After obturation, all access cavities were sealed with temporary filling material (Coltosol-F, Coltene-Whaledent, Switzerland) and the roots were stored in distilled water at room temperature for 24 hours. Then, the post spaces were all prepared to a depth of 10 mm with preparation drills (size 3, RelyX Fiber Post drill; 3M ESPE, Seefeld, Germany). Five mm of intact gutta-percha was left behind to preserve the apical seal. Post size 3 (RelyX Fiber Post, 3M ESPE, Seefeld, Germany, 0.9-mm diameter apically, 1.9-mm diameter coronally and 0.10 taper) was tried to ensure that the posts would reach the bottom of the post space. Presence of any residual gutta-percha in the walls of post space was checked by radiographic evaluation. Before cementation of the posts, different irrigation procedures were performed. In the first group, only distilled water was used for irrigation (group 1). In the second group, after copious irrigation with 5.25% NaOCl, 17% EDTA and distilled water were used subsequently (group 2). In the third group, 5.25% NaOCl, 17% EDTA and distilled water were used followed by 10% sodium ascorbate irrigation for 10 minutes (group 3). The post spaces were completely dried with absorbent paper points (Dentsply Maillefer, Ballaigues, Switzerland) and the surfaces of the posts were cleaned with alcohol and dried with air. For cementation of fiber posts, the dualpolymerized self adhesive resin luting agent (RelyX Unicem, 3M ESPE, Seefeld, Germany) was prepared according to the manufacturer s instructions. RelyX Unicem Aplicap was mixed for 15 seconds and the special elongation tip was inserted to RelyX Unicem Aplicap. The cement was applied into the orifice of root canals. The posts were inserted into the canal to full depth by using finger pressure, and excess was immediately removed. The light curing was performed for 40 seconds through the posts, the tip of the light unit (Optilux 501, Kerr, USA) directly in contact with the coronal end of the posts. All the post-cemented roots were placed in distilled water at room temperature for 24 hours. Push-out test Then, each root was sectioned perpendicular to the long axis with a low speed saw (Buehler Ltd., Lake Bluff, IL, USA) to create 1.00±0.05-mm-thick slices. For each root, 3 slices from each region (coronal, middle, apical) were sectioned and totally 90 slices were collected. Each slice was marked on its coronal side with an indelible marker. The thickness of the slices were measured with a micro-measuring device in which the minimum reading value was set at ±0.001 mm (Mitutoyo Digimatic Caliper, Mitutoyo Corp., Kawasaki, Japan), and the radius of the canals were measured by using stereomicroscope (Leica MZ16 FA, Houston, TX). The push-out tests were performed at a crosshead speed of 1 mm/min by using a universal testing machine (Instron, 3345, Instron Corp., Norwood, MA, USA). The push-out jig was placed on the test machine. Care was taken to center the push-out pin (1.0 mm in diameter) on the center of the post surface, without stressing the surrounding post space walls. The load was applied to the apical side of the root slice to avoid any limitation of post movement due to post space taper. The peak force at the point of extrusion of the post segment from the slice was taken as point of bond failure, and the values were recorded in Newton (N). To express the bond strength in MPa, the load values recorded in Newton were divided by the area of the bonded interface. It was calculated using this formula: A=2πrh (A: bonded area, r: radius, h: thickness of the slices). Push-out test After testing the push-out bond strengths, all samples were analyzed under a scanning electron microscope (SEM) to determine the type of failure. Failure of fractured specimens were determined and classified in 5 categories, described by Perdigao et al. (15): 1: Adhesive failure between the post and resin cement, there is no cement around the post. 2: Mixed failure between the post and resin cement, there is resin cement 0-50% in percentage around the post. 3: Mixed failure between the post and resin cement, there is resin cement 50-100% in percentage around the post. 4: Adhesive failure between the dentin and resin cement, the post is surrounded with resin cement. 5 : Cohesive failure in dentin. Failure mode analysis After testing the push-out bond strengths, all samples were analyzed under a scanning electron microscope (SEM) to determine the type of failure. Failure of fractured specimens were determined and classified in 5 categories, described by Perdigao et al. (15):

8 The bond strengths of fiber posts 1: Adhesive failure between the post and resin cement, there is no cement around the post. 2: Mixed failure between the post and resin cement, there is resin cement 0-50% in percentage around the post. 3: Mixed failure between the post and resin cement, there is resin cement 50-100% in percentage around the post. 4: Adhesive failure between the dentin and resin cement, the post is surrounded with resin cement. 5: Cohesive failure in dentin. Statistical analysis Statistical analyses were performed to evaluate the differences between bond strengths. One-way analysis of variance (ANOVA) and Tukey HDS tests were used to analyze the data and the significance level was set at p<0.05. RESULTS Push-out bond strength The push-out bond strength values are shown in Table 2. The bond strength for coronal region was found as 10.38±4.11 MPa in control group, 8.04±3.3 MPa in group 2 (NaOCl and EDTA) and 10.35±2.46 MPa in group 3 (NaOCl and EDTA and sodium ascorbate). The bond strength for middle region was found as 7.82±3.63 MPa in control group, 7.50±2.72 MPa in group 2 and 9.58±3.49 MPa in group 3. The bond strength for apical region was found as 7.73±3.12 MPa in control group, 9.57±2.42 MPa in group 2 and 9.89±3.06 MPa in group 3. There were no statistically significant differences between the bond strength values of the groups related to irrigation procedures (p>0.05). In addition, there were no statistically significant differences between the bond strength values of the groups related to different regions of the roots (p>0.05). Material Manufacturer Composition Lot number Parallel oriented and 3M ESPE, equal distributed glass RelyX Seefeld, fibers, embedded into Fiber Post Germany a composite resin 113770907 matrix Powder: glass fillers, silica, calcium RelyX hydroxide, self-cure Unicem initiators, pigments, Aplicap 3M ESPE, light-cure initiators (selfadhesive Germany Seefeld, Liquid: methacrylated phosphoric esters, resin dimethacrylates, cement) acetate, stabilisers, 357281 self-cure initiators Table 1: Materials used in this study Coronal region Middle region Apical region Total Mean (sd) Group 1 (distilled water) 10.38 (4.11) Group 2 (NaOCl and EDTA) 8.04 (3.30) Group 3 (NaOCl and EDTA and 10.35 (2.46) sodium ascorbate) p 0.222 Group 1 (distilled water) 7.83 (3.63) Group 2 (NaOCl and EDTA) 7.50 (2.72) Group 3 (NaOCl and EDTA and 9.58 (3.49) sodium ascorbate) p 0.331 Group 1 (distilled water) 7.73 (3.12) Group 2 (NaOCl and EDTA) 9.57 (2.42) Group 3 (NaOCl and EDTA and 9.89 (3.06) sodium ascorbate) p 0.213 Group 1 (distilled water) 8.64 (3.73) Group 2 (NaOCl and EDTA) 8.37 (2.88) Group 3 (NaOCl and EDTA and 9.94 (2.94) sodium ascorbate) p 0.134 Table 2: Mean push-out bond strength values (sd) in MPa. Failure mode analyses According to the SEM analysis, mixed failure between the post and resin cement which included 50-100% resin cement remaining around the post (failure type 3) was the most frequently observed failure type (45%, n=41). The cohesive failure in dentin (failure type 5) was the least observed failure type (n=2). Other failure types were determined as adhesive failure between the post and resin cement which included no cement around the post (failure type 1, n=7), mixed failure between the post and resin cement which included 0-50% resin cement around the post (failure type 2, n=22) and adhesive failure between the dentin and resin cement in which the post was surrounded with resin cement (failure type 4, n=18) (Table 3). Failure mode Groups Region 1 2 3 4 5 Group 1 Coronal 0 5 5 0 0 Middle 1 2 7 0 0 Apical 2 0 8 0 0 Group 2 Coronal 2 1 2 5 0 Middle 2 0 2 6 0 Apical 0 2 5 3 0 Group 3 Coronal 0 3 5 1 1 Middle 0 3 4 2 1 Apical 0 6 3 1 0 Total 7 22 41 18 2 Table 3: Distribution of the failure modes following the pushout test

9 DISCUSSION The dislocation resistance of the FRC posts is mainly related to the luting agent and the success of the luting procedure to dentin. Although clinical experiences give exact information of bonding effectiveness, laboratory researches provide first-hand information on newly introduced materials (16). For quantitative evaluation of adhesion reliability, bond strength tests suggest that the stronger the bond at the tooth-material interface, the better it will resist undesirable stresses (17). Several bond strength tests have been developed to evaluate clinical performances of dental materials. When FRC posts were first introduced in the 1990s, conventional shear and tensile tests had been criticized by some researchers (18). The bond strengths were entirely depended on experimental conditions and this was a limitation of these methods (19). The microtensile bond strength testing was introduced because it has the ability to reflect the true bond strength, to measure adhesion to small surfaces, to assess local variations and to obtain multiple specimens from a single tooth (20). The push-out test, first used in 1996, is a valid method to investigate the retention of posts. Factors affecting the retention such as root canal treatments, timing of post cementation, type of adhesive and polymerization mode, properties of the luting agent, and thickness of the cement layer have been evaluated with this method (21). Also the degree of bond maturation over time and bond degradation under fatigue loading has been studied with the push-out test (16). This test is involved sectioning the posted root into 1 mm thick slices, and loading the post within each slice with a plunger until failure occurs. It provides a better estimation of the bonding strength than the conventional shear test, because the fracture occurs parallel to the dentin-bonding interface (22). In addition, the push-out test has been considered more dependable than the microtensile test for bonded posts because of the high number of premature failures occurring during specimen preparation and the large data distribution associated with microtensile testing (23). Moreover, the push-out test simulates the clinical conditions more closely (18). The adhesive systems that have been proposed for bonding FRC posts to root canal dentin can be divided into self-etching adhesives and etch-and-rinse systems (24). Recently, self-adhesive resin cement, RelyX Unicem, was introduced. The multifunctional monomers with phosphoric acid groups simultaneously demineralize and infiltrate enamel and dentin. The adhesion obtained with this agent is claimed to rely on micromechanical retention and chemical interaction between monomer acidic groups and hydroxyapatite (25). Self-adhesive cements do not require any pretreatment of dentin and this offers a shorter application time and reduced number of clinical steps (4). In this study, this cement is preferred to eliminate the variability depending on multiple steps. Self-adhesive resin cements react with the hydroxyapatite of the dental hard tissues. However, they have limited capacity to diffuse and decalcify the dentin because of their high viscosity which increases the acid-base reaction (26). They are unable to dissolve the smear layer completely. Despite the initial acidic ph (2.1), RelyX Unicem does not produce any dentin demineralization and hybridization (27, 28). Behr et al (29). revealed that the adhesive interface appeared similar to established dual-cured luting agents. The post space preparation and cementation can be performed immediately or later, after the endodontic treatment. In vitro studies reported less apical leakage in case of immediate post space preparation and post cementation (13, 30), and immediate approach is less time consuming (31). However, the timing of these procedures may affect the retention of the posts. Vano et al. (32) investigated the effect of immediate versus delayed cementation of the FRC posts on the retention and found that push-out bond strength obtained with immediate approach was significantly lower than those obtained with delayed approach (24 h and 1 week). This finding was attributed to poor adhesion caused by contamination of the post space walls with the unset eugenol sealer. In the present study, non-eugenol sealer was used to eliminate this factor. On the other hand, obturated roots were stored in distilled water for 24 hours before post space preparation and post cementation to allow the root canal fillings to set. The preparation of the post space using post drills results in an additional and thicker smear layer, which is composed of both dentin debris and sealer or gutta-percha remnants, which would affect the FRC post adhesion (33). These remnants may decrease the penetration and chemical interaction of the bonding agents. Therefore, achieving a clean dental surface with irrigation the post space after drilling procedures is a critical step for optimal FRC post retention (34). Surface treatments of root dentin with different agents may cause alterations in the chemical and structural

10 The bond strengths of fiber posts composition of dentin, which may change its permeability and solubility (35). These alterations have the potential to affect the bonding of adhesive materials to the treated dentin surfaces (36). In the present study, a conventional irrigation procedure was followed during shaping the root canals. According to this procedure, the canals were irrigated with copious amounts of NaOCl. After shaping procedure, EDTA was used because of its smear-removing efficacy. As it was demonstrated that dental erosion was more evident with final flush of NaOCl (37, 38), distilled water was used for the final irrigation. The presence of the smear layer may be a weak link for self-adhesive cements similar to glass ionomers (28). NaOCl is a nonspecific oxidizing and proteolytic agent which denatures the collagen components of the smear layer (39). The oxidizing properties of the NaOCl cause negative effect on the initiation of polymerization of the adhesive system, leading to lower bond strength (6). Vonghpan et al. (10) suggested that endodontically treated teeth which were irrigated with NaOCl can be acid-etched and bonded immediately, with the use of 10% sodium ascorbate without any adverse effect. They observed rougher surface and more clearly visible collagen fibrils on the intertubular dentine after treating with 10% sodium ascorbate. The increased bonding strength was attributed to this finding. Sodium ascorbate is a salt of ascorbic acid, which is a water-soluble vitamin known as vitamin C. This solution has antioxidant properties. As vitamin C and its salts are non-toxic and are used in food industry, it seems that their use on dentine will create no adverse biological effect. It is reported that sodium ascorbate increases bonding strength of resins to dentin (40). Various results have been reported regarding the positive influence of sodium ascorbate solutions on the bond strengths of resin materials to dentine (9-12). In Morris et al. s study (9), it was stated that irrigation with 5% NaOCl (7.7 MPa) decreased the bond strength of resin to dentin compared to distilled water (23.6 MPa). On the other hand, they applied 10% sodium ascorbate and found that this procedure increased the bond strength (27.7 MPa). Vongphan et al. (10) evaluated the microtensile bond strength of resin to dentin after treated with different irrigates and found that the bond strength of dentin irrigated with 5.25% NaOCl for 10 minutes was significantly lower (21 MPa) than the bond strength of dentin irrigated with 5.25% NaOCl and 10% sodium ascorbate for 10 minutes (40.5 MPa). Weston et al. (11) investigated the effectiveness of sodium ascorbate to increase bond strengths when used for less time (1 to 3 minutes) than recommended by the manufacturer (10 minutes) or at different concentrations (10%, 20%). They stated that there were no significant differences between those canals treated with 10% sodium ascorbate and those treated with 20% sodium ascorbate regardless of treatment time, and 1-min treatment (23.8 MPa) was just as effective as 10-min treatment (29.1 MPa). However, they found statistically significant differences among the all sodium ascorbate groups (22.0 MPa- 29.1 MPa) and 5.25% NaOCl groups (8.3 MPa) (11). Da Cunha et al. (12) compared 3 different irrigation procedures for the evaluation of push-out bond strength of FRC posts to dentin. They reported that application of 5% NaOCl for 10 minutes decreased the bond strength compared to distilled water and irrigation of 10 % sodium ascorbate for 10 minutes restored the bond strength (12). These results can be explained by the antioxidant ability of sodium ascorbate. In the present study, there were no statistically significant differences between the bond strength values of the groups, both related to irrigation procedures and the root regions. However, the mean bond strength values of the sodium ascorbate group (9.94 MPa) were numerically higher than the other groups. Similarly, the bond strength values of the NaOCl and EDTA group (8.37 MPa) were numerically lower than the other groups. A possible explanation for these findings could be that the post space preparations and the adhesive procedures were performed 1 day after the root-canal treatment. In the other studies (9-12), all these procedures were performed 1 week later. Reduction in bond strength may be related to changes in the physical and chemical properties of dentin after application of NaOCl and EDTA (41). EDTA is a chelator agent that reacts with calcium ions in the hydroxyapatite crystals of dentin. It softens dentin especially in the middle and coronal peritubular dentin. It is very effective in smear layer removal. It is considered to improve the retention of the FRC posts by removing the smear layer, opening the dentin tubules and etching the intertubular dentin that leads to better contact between the resin cement and the dentin (42). In the present study, EDTA was used after NaOCl irrigate for the purpose of applying routine clinical irrigation procedure. Higher bond strength values were obtained in group 2 (NaOCl and EDTA) than expected, and this result can be attributed to the irrigation of root canals with EDTA. The secondary aim of this study was to compare the regional differences on the bond strengths of FRC posts for all irrigation procedures. However, a statistically significant difference was not found between the coronal, middle and apical regions of the root canal dentin.

11 According to SEM evaluation of this study, mixed failures between post and resin cement (type 3) were observed frequently (66%) in group 1. Most of the dentinal tubules were closed probably because of the smear layer that could not be dissolved by rinsing distilled water. No hybrid layer or resin tag formation was observed in this group (Figure 1 and Figure 2) Figure 3: : Fe-SEM image of Rely X Unicem and NaOCl, EDTA treated dentin interface. An interaction zone (white arrows) and large funnel shaped resin tags (black arrow) were detected. The interaction zone appeared to have a larger diameter compared to those observed in the control and in the NaOCl-EDTA-Sodium Ascorbat group. (D: Dentin; RU: Rely X Unicem; FP:Fiber post). Figure 1: Fe-SEM image of the Rely X Unicem dentin interface from the control group. At the cement-dentin interface a thin interaction zone with few resin tags were observed. (D: Dentin; RU: Rely X Unicem; FP:Fiber post). Figure 4: Dentin side of a fractured push-out specimen from NaOCl and EDTA treated group showing adhesive failure mode. Most of the resin tags were pulled out of the tubules (black arrow) whereas infiltration into some tubules were not evident (white arrow). Figure 2: Dentin side of a fractured push-out specimen from Rely X Unicem control group showing mixed failure mode with smear layer covered dentin (D) and resin cement (RU). In group 2, it was observed that the smear layer was removed completely from the NaOCl EDTA treated dentin, and an erosive surface occurred with large opened dentinal tubules and resin tags. Although resin tag formation was detected, no hybrid layer was observed in group 2. Adhesive failures between dentin and resin cement (type 4) were observed frequently (46%) and this may be related to lower bonding strength (Figure 3 and Figure 4). In group 3, the application of 10% sodium ascorbate on the NaOCl EDTA treated dentin surface showed no obvious morphology change compared to group 2. Mixed failures between the post and resin cement (type 2 and 3) were detected frequently in this group (80%). Cohesive failures within the dentin were observed in 2 samples (Figure 5 and Figure 6).

12 Figure 5: : Fe-SEM image of Rely X Unicem and NaOCl-EDTA- Sodium Ascorbat treated dentin interface. A thin interaction zone (white arrows) with a lot of resin tags (black arrow) were evident. (D: Dentin; RU: Rely X Unicem; FP:Fiber post). Figure 6: Dentin side of a fractured push-out specimen from NaOCl- EDTA- Sodium Ascorbat treated group showing mixed failure mode with fractured resin tags into the tubules (black arrow) and resin cement (white arrow). CONCLUSIONS The short-term effect of sodium ascorbate irrigation on the push-out bond strengths of FRC posts to root canal dentin was determined in vitro. The use of 10% sodium ascorbate after irrigation the dentin with NaOCl and EDTA improved the bond strengths but this difference was not statistically significant. The surface treatment of dentin with sodium ascorbate requires further investigation to determine appropriate timing or concentration for achieving optimal adhesion at the resin cement-dentin interface after exposure to NaOCl. ACKNOWLEDGEMENT The authors gratefully acknowledge the funding of this work by the Scientic and Technical Research Council of Turkey, REFERENCES The bond strengths of fiber posts TÜBİTAK (Project No: 109S290). 1. Sirimai S, Riis DN, Morgano SM. An in vitro study of the fracture resistance and the incidence of vertical root fracture of pulpless teeth restored with six post-andcore systems. J Prosthet Dent, 1999; 81:262-269. 2. Cheung W. A review of the management of endodontically treated teeth. Post, core and the final restoration. J Am Dent Assoc, 2005; 136: 611-619. 3. Cormier CJ, Burns DR, Moon P. In vitro comparison of fracture resistance and failure mode of fiber, ceramic, and conventional post systems at various stages of restoration. J Prosthodont, 2001; 10:26-36. 4. Radovic I, Mazzitelli C, Chieffi N, Ferrari M. Evaluation of the adhesion of fiber posts cemented using different adhesive approaches. Eur J Oral Sci, 2008; 116:557-563. 5. Cagidiaco MC, Goracci C, Garcia-Godoy F, Ferrari M. Clinical studies of fiber posts: a literature review. Int J Prosthodont, 2008; 21:328-336. 6. Nikaido T, Takano Y, Susafuchi Y, Burrow MF, Tagami J. Bond strengths to endodontically-treated teeth. Am J Dent, 1999; 12:177-180. 7. Rueggeberg FA, Margeson DH. The effect of oxygen inhibition on an unfilled/filled composite system. J Dent Res, 1990; 69:1652-1658. 8. Lai SCN, Mak YF, Cheung GSP, Osorio R, Toledano M, Carvalho RM, et al. Reversal of compromised bonding to oxidized etched dentine. J Dent Res, 2001; 80:1919-1924. 9. Morris MD, Lee KW, Agee KA, Bouillaguet S, Pashley DH. Effects of sodium hypochlorite and RC-prep on bond strengths of resin cement to endodontic surfaces. J Endod, 2001; 27:753-757. 10. Vongphan N, Senawongse P, Somsiri W, Harnirattisai C. Effects of sodium ascorbate on microtensile bond strength of total-etching adhesive system to NaOCl treated dentine. J Dent, 2005; 33:689-695. 11. Weston CH, Ito S, Wadgaonkar B, Pashley DH. Effects of time and concentration of sodium ascorbate on reversal of NaOCl-induced reduction in bond strengths. J Endod, 2007; 33:879-881. 12. Da Cunha LF, Furuse AY, Mondelli RF, Mondelli J. Compromised bond strength after root dentin deproteinization reversed with ascorbic acid. J Endod, 2010; 36:130-134. 13. Karapinar-Kazandağ M, Tanalp J, Bayrak OF, Sunay H, Bayirli G. Microleakage of various root filling systems by glucose filtration analysis. Oral Surg Oral Med Oral Pathol Oral Radiol Endod, 2010;109:96-102. 14. Villat C, Machtou P, Naulin-Ifi C. Multidisciplinary approach to the immediate esthetic repair and longterm treatment of an oblique crown-root fracture. Dent Traumatol, 2004; 20:56-60. 15. Perdigão J, Gomes G, Lee IK. The effect of silane on the

13 bond strengths of fiber posts. Dent Mater, 2006; 22:752-758. 16. Goracci C, Grandini S, Bossù M, Bertelli E, Ferrari M. Laboratory assessment of the retentive potential of adhesive posts: a review. J Dent, 2007; 35:827-835. 17. De Munck J, Van Landuyt K, Peumans M, Poitevin A, Lambrechts P, Braem M, et al. A critical review of the durability of adhesion to tooth tissue: methods and results. J Dent Res, 2005; 84:118-132. 18. Sudsangiam S, Van Noort R. Do dentin bond strength tests serve a useful purpose? J Adhes Dent, 1999; 1:57-67. 19. Versluis A, Tantbirojn D, Douglas WH. Why do shear bond tests pull-out dentin? J Dent Res, 1997; 76:1298-1307. 20. Pashley DH, Carvalho RM, Sano H, Nakajima M, Yoshiyama M, Shono Y, et al. The microtensile bond test: a review. J Adhes Dent, 1999; 1:299-309. 21. Patierno JM, Rueggeberg FA, Anderson RW, Weller RN, Pashley DH. Push-out and SEM evaluation of resin composite bonded to internal cervical dentin. J Endod Dent Traumatol, 1996; 12:227-236. 22. Drummond JL, Sakaguchi RL, Racean DC, Wozny J, Steinberg AD. Testing mode and surface treatment effects on dentin bonding. J Biomed Mater Res, 1996; 32:533-541. 23. Goracci C, Tavares AU, Fabianelli A, Monticelli F, Raffaelli O, Cardoso PC, et al. The adhesion between fiber posts and root canal walls: comparison between microtensile and push-out bond strength measurements. Eur J Oral Sci, 2004; 112:353-361. 24. Bitter K, Meyer-Lueckel H, Priehn K, Kanjuparambil JP, Neumann K, Kielbassa AM. Effects of luting agent and thermocycling on bond strengths to root canal dentine. Int Endod J, 2006; 39: 809-818. 25. Radovic I, Monticelli F, Goracci C, Vulicevic ZR, Ferrari M. Self-adhesive resin cements: a literature review. J Adhes Dent, 2008; 10:251-258. 26. De Munck J, Vargas M, Van Landuyt K, Hikita K, Lambrechts P, Van Meerbeek B. Bonding of an autoadhesive luting material to enamel and dentin. Dent Mater, 2004; 20:963-971. 27. Yang B, Ludwig K, Adelung R, Kern M. Micro-tensile bond strength of three luting resins to human regional dentin. Dent Mater, 2006; 22:45-56. 28. Al-Assaf K, Chakmakchi M, Palaghias G, Karanika- Kouma A, Eliades G. Interfacial characteristics of adhesive luting resins and composites with dentine. Dent Mater, 2007; 23:829-839. 29. Behr M, Rosentritt M, Regnet T, Lang R, Handel G. Marginal adaptation in dentin of a self-adhesive universal resin cement compared with well-tried systems. Dent Mater, 2004; 20:191-197. 30. Solano F, Hartwell G, Appelstein C. Comparison of apical leakage between immediate versus delayed post space preparation using AH Plus sealer. J Endod, 2005; 31:752-754. 31. Saunders EM, Saunders WP, Rashid MY. The effect of post space preparation on the apical seal of root fillings using chemically adhesive materials. Int Endod J, 1991; 24:51-57. 32. Vano M, Cury AH, Goracci C, Chieffi N, Gabriele M, Tay FR, Ferrari M. Retention of fiber posts cemented at different time intervals in canals obturated using an epoxy resin sealer. J Dent, 2008; 36:801-817. 33. Goracci C, Sadek FT, Fabianelli A, Tay FR, Ferrari M. Evaluation of the adhesion of fiber posts to intraradicular dentin. Oper Dent, 2005; 30:627-635. 34. Boone KJ, Murchison DF, Schindler WG, Walker WA 3rd. Post retention: the effect of sequence of post-space preparation, cementation time, and different sealers. J Endod, 2001; 27:768-771. 35. Tang W, Wu Y, Smales RJ. Identifying and reducing risks for potential fractures in endodontically treated teeth. J Endod, 2010; 36:609-617. 36. Dogan Buzoglu H, Calt S, Gümüsderelioglu M. Evaluation of the surface free energy on root canal dentine walls treated with chelating agents and NaOCl. Int Endod J, 2007; 40:18-24. 37. Niu W, Yoshioka T, Kobayashi C, Suda H. A scanning electron microscopic study of dentinal erosion by final irrigation with EDTA and NaOCl solutions. Int Endod J, 2002; 35:934-939. 38. Grande CM, Plotino G, Falanga A, Pomponi M, Somma F. Interaction between EDTA and Sodium hypoclorite: Anuclear Magnetic Resonance Analysis. J Endod, 2006; 32:460-464. 39. Zhang K, Kim YK, Cadenaro M, Bryan TE, Sidow SJ, Loushine RJ, Ling JQ, Pashley DH, Tay FR. Effects of different exposure times and concentrations of sodium hypochlorite/ethylenediaminetetraacetic acid on the structural integrity of mineralized dentin. J Endod, 2010; 36:105-109. 40. Soeno K, Taira Y, Jimbo R, Sawase T. Surface treatment with ascorbic acid and ferric chloride improves the micro-tensile bond strength of 4-META/MMA-TBB resin to dentin. J Dent, 2008; 36:940-944. 41. Yiu CK, García-Godoy F, Tay FR, Pashley DH, Imazato S, King NM, Lai SC. A nanoleakage perspective on bonding to oxidized dentin. J Dent Res, 2002; 81:628-632. 42. Rasimick BJ, Shah RP, Musikant BL, Deutsch AS. Effect of EDTA conditioning upon the retention of fibre posts luted with resin cements. Int Endod J, 2008; 41:1101-1106.

14

ÖZGÜN ARAŞTIRMA 15 Erbium-Doped Yttrium Aluminum Garnet (Er:YAG) lazerin periodontitisli kök yüzeylerinde neden olduğu morfolojik değişikliklerin taramalı elektron mikroskobu ile değerlendirilmesi Effect of Erbium-Doped Yttrium Aluminum Garnet (Er: YAG) laser on the morphology of periodontally diseased root surfaces with scanning electron microscopy Dr. Ahmet Aydoğdu Başkent Üniversitesi İstanbul Hastanesi, İstanbul Yrd. Doç. Dr. Umut Ballı Bülent Ecevit Üniversitesi, Diş Hekimliği Fakültesi, Periodontoloji Anabilim Dalı, Zonguldak Yrd. Doç. Dr. İlker Keskiner Ondokuz Mayıs Üniversitesi Diş Hekimliği Fakültesi, Periodontoloji Anabilim Dalı, Samsun Doç. Dr. Seda Sağır Biruni Üniveristesi Diş Hekimliği Fakültesi, Periodontoloji Anabilim Dalı, İstanbul Geliş tarihi: 5 Mayıs 2015 Kabul tarihi: 21 Temmuz 2015 Yazışma adresi: Doç. Dr. Seda Sağır Biruni Üniveristesi Diş Hekimliği Fakültesi Periodontoloji Anabilim Dalı Topkapı, İstanbul, Türkiye E-mail: sozturan@biruni.edu.tr ÖZET Amaç: Bu çalışmanın amacı kök yüzeyi düzleştirilmesi sırasında kullanılan el aletleri, ultrasonik kazıyıcılar ve Erbium-Doped Yttrium Aluminum Garnet (Er:YAG) lazerin kullanılması ile kök yüzeyinde oluşabilecek morfolojik değişiklerin değerlendirilmesidir. Gereç ve yöntem: Periodontal nedenlerle çekimine karar verilmiş 60 adet diş toplanmıştır. Dişlerin çekim sonrası kökleri ve kök uçları elmas frez ile kesilerek uzaklaştırıldı. Her grupta 30 diş olmak üzere 2 grup oluşturuldu. İlk grubta kök yüzey düzleştirilmesi işlemi el aletleri ve ulrasonik aletlerle yapıldı. İkinci grupta kök yüzey düzleştirilmesi el aletleri, ulrasonik aletler ve Er:YAG lazer ile yapıldı. Daha sonra dişler kurutularak taramalı elektron mikroskobu (SEM) ile incelemeye hazır hale getirildi. Bulgular: 500X büyütmede yapılan kök yüzey incelemesinde kök yüzeylerinde erime, karbonizasyon oluşumu gibi ileri morfolojik değişikliklere rastlanmadı. Her iki grupta da kök yüzeylerinde kalkulus uzaklaştırıldı. Ancak lazer uygulanan grupta kök yüzey düzensizlikleri daha fazla izlenmiştir. Sonuç: 160 mj/pulse ile Er:YAG lazerin, el aletlerine ve ultrasonik kazıyıcılara ek olarak kullanılması, kök yüzeylerinde çok ileri hasara neden olmamakla birlikte, kök yüzeylerinde çok daha fazla düzensizliğe neden olmuştur. Anahtar kelimeler: Er:YAG lazer, kök yüzey düzleştirilmesi, taramalı elektron mikroskobu, ultrasonik kazıyıcı SUMMARY Objectives: The purpose of the present study was to evaluate the ultra-structural changes which happened after treatment of the root surfaces with hand and ultrasonic instrumentation followed by Erbium-Doped Yttrium Aluminum Garnet (Er:YAG) laser irradiation. Materials and Methods: A total of 100 freshly extracted periodontally involved single rooted teeth were collected. Crown and apical parts of the root were cut off using a diamond bur. Teeth were randomly divided into 2 groups having 50 teeth in each group. Group1: were treated with hand and ultrasonic scaling samples, group2: were root planed using conventional hand curette, ultrasonic scaler and Er:YAG laser. Furthermore, the teeth were dried, coated and monitored with scanning electron microscope (SEM). Results: Photomicrographs from samples of root surfaces which were taken at magnifications up to 500X revealed that there were not any severe morphologic changes, such as melting and charring, in any group. Both of the groups showed effectiveness in calculus removal. However, the samples treated by laser irradiation showed more irregularities and distortions. Conclusions: Er:YAG laser setting at 160mj/pulse, as an

16 Lazer destekli kök yüzey düzleştirilmesi adjunctive to traditional scaling and root planning, did not induce severe damages to root surfaces, although root surface irregularities were more pronounced in laser treated group compare to hand and ultrasonic scaling group. Keywords: Er:YAG lasers, root planning, scanning electron microscopy, ultrasonic scaler. GİRİŞ Son yıllarda lazerlerin kullanım alanlarında meydana gelen ilerleme ile periodontoloji alanında da kullanımı gündeme gelmiştir. Lazer, periodontolojide cerrahi ve cerrahi olmayan periodontal tedavilerde kullanılabilir. CO 2, diode ve Nd:YAG lazerler periodontolojide yumuşak doku tedavilerinde, Erbium lazerler ise hem yumuşak hem de sert dokularda kullanılabilirler. Lazerle tedavi sırasında smear tabakası oluşmadığı ve geleneksel mekanik tedavi ile ulaşılamayan bölgelere bile ulaşılabildiği bildirilmiştir. Bununla birlikte, diştaşı temizliğinde tek başına lazerlerin mekanik tedavi kadar etkili olmadığı da gösterilmiştir (1). Lazerlerin güçlü ablasyon, hemostatik ve bakterisidal etkilerinden yararlanılarak cerrahi olmayan periodontal tedavilerde mekanik tedaviye ek olarak kullanılabilecek en iyi yöntemlerden biri olduğu bildirilmiştir (1,2). Kalıcı ceplerin tedavisinde lazerlerin başarılı sonuçlar sağladığı rapor edilmiştir (1-3). Lazerler cerrahi periodontal tedavide yönlendirilmiş doku rejenerasyonu, flep operasyonları, deepitelizasyon, depigmentasyon, frenektomi, prekanseröz ve malign lezyonların tedavisinde, idame tedavide, peri-implantitis tedavisinde, osteotomi ve/ veya osteoktomide kullanılabililir (1-4). Başlangıç periodontal tedavi sırasında hastalıklı kök yüzeyinin mekanik temizliği genellikle el aletleri ile ya da ultrasonik cihazlar aracılığı ile yapılmaktadır. Ultrasonik cihazlar hekime çalışma kolaylığı sağladığı için tercih edilmektedir. Ancak bu cihazların çalışırken çıkardığı ses ve neden olduğu vibrasyon hastada strese neden olmaktadır. Konvansiyonel el aletleri kullanılarak yapılan tedavi ise hekime el hassasiyeti sağlamakla birlikte hastada ağrıya neden olabilmekte, daha fazla kanamaya ve hastada huzursuzluğa neden olmaktadır. Ayrıca el aletleri kullanılarak yapılan tedavinin başarısı çoğu zaman hekimin el becerisi ile ilişkilidir. Bazı klinisyenler el aletlerinin kök yüzey düzleştirme de çok başarılı olduğunu düşünürken, ultrasonik cihazların ise kök yüzeylerine zarar verebileceğini iddia etmektedirler. Bu nedenlerle son zamanlarda farklı dalga boylarında ki lazerlerin diş hekimliğinde kullanımı çok daha popular hale gelmiştir. Lazerlerin antibakteriyel etkisi olduğu (3), yumuşak doku küretajı ve deepitelizasyon yaptığı (4), düşük enerji seviyelerinde biostimulasyon sağladığı (5), kök yüzey modifikasyonu yaptığı bilinmektedir(6). Erbium ailesi diş ve kök yüzeyinde bulunan kalkulusu uzaklaştırma etkilidir ancak cerrahi olmayan periodontal tedavide tek başına kullanımı önerilmemektedir. Tek başına kullanıldığında kalkulusun uzaklaştırılması için yüksek enerjili kullanımı gerekebilmekte ve dişin fazla ısınması, çatlakların, pitlerin oluşması gibi olumsuz yan etkilere neden olabilmektedir (7). De Mendonca ve ark. yaptıkları çalışmada 120 mj/pulse ile Er:YAG lazeri kök yüzey düzleştirmesi işleminde kullanmış el aletleri kullanılarak yapılan konvansiyonel periodontal tedavi ile karşılaştırdığında kök yüzeyinde düzensizlikler izlemiş ve yeterli kök yüzey düzleştirmesi sağlayamamıştır (8). Bu nedenle araştırmacıların çoğu erime ve diş yüzeyinde bozulmayı önlemek için lazerlerin daha düşük enerji seviyelerinde kullanımını önermektedirler (9). Lazerlerin fibroblast hücrelerinin adezyonunu kolaylaştırıcı etkileri vardır ve bu nedenle, konvansiyonel tedaviye ek olarak cep içerisinde kullanımı bazı araştırmacılar tarafından önerilmektedir (10). Lazer uygulaması ile elde edilen kök yüzey biomodifikasyonu fibroblast hücrelerinin adezyonunu kolaylaştırmaktadır. Erbium lazerlerin kök yüzeylerinde fiziksel ve kimyasal etkileri söz konusudur. Bu yüzey değişiklerinin değerlendirmenin ise iki yolu vardır. 1) kök yüzey düzensizliklerinin kantitatif analizi, 2) taramalı elektron mikroskobu (SEM) ile kök yüzeyinin kalitatif olarak incelenmesi (11). Yayınlanan meta-analizler Erbium lazerlerin tek değil ama periodontal tedaviye destek olarak kullanılmanı önermektedirler (12). Bu çalışmanın amacı periodontitisli hastalarda konvansiyonal olarak uygulanan tedaviye ek olarak kullanılan Er:YAG lazerin kök yüzeyinde neden olduğu olası değişiklikleri SEM analizi ile incelemek ve değerlendirmektir. GEREÇ VE YÖNTEM Çalışma kullanılmak üzere periodontal nedenlerle çekilmesine karar verilmiş 50 adet mandibular ya da maksillar tek köklü dişler toplanmıştır. Dişlerin çekiminden hemen sonra dişlerin kron ve kök uçları kesilerek kalan kökler fosfat yüklü izotonik çözeltide saklandı. Yeterli örnek sayısı sağlandıktan sonra kök yüzeylerinin tedavisinin sağlanabilmesi için kökler akrilik rezin içine gömüldü. Örnekler 2 gruba ayrıldı. Grup 1) kök yüzey düzleştirilmesi el aletleri ve ultrasonik cihazlar ile yapıldı. Grup 2) kök yüzeyi düzleştirilme işlemi el aletleri, ultrasonik cihaz ve Er: YAG lazer (160 mj/pulse, 10 pulses/second, suhava irrigasyonu) ile yapıldı. SEM analizi için örnekler %2,5 gluteraldehit eklenmiş fosfat tamponlu izotonik çözelti içinde fikse edildi. Daha sonra

17 yıkandı ve kurutuldu. SEM uygulaması için yüzey kaplama işlemleri yapıldı. Kök yüzeylerinin X500 magnifikasyonda fotografları çekildi. BULGULAR Tedavi işlemleri sonrası kök yüzey morfolojileri SEM ile değerlendirildi. Sonuçlar tedavi yöntemlerinin kalkulusun uzaklaştırılmasında yeterli olduğunu gösterdi (Resim 1, 2). Kök yüzeylerinde erime ya da karbonizasyon gibi termal yan etkiler izlenmedi. Lazer uygulanan grupta kök yüzey düzensizliği diğer gruba göre çok daha fazlaydı ve belirgin yarıklarla adacıklara ayrılmıştı (Resim 2). Genel olarak sementte değişiklik izlenmemekle birlikte açığa çıkmış dentin tübüllerine her iki grupta da birer örnek olmak üzere 2 örnekte rastlandı. TARTIŞMA Periodontal patojenlerle karşılaşan kök yüzeylerinde ciddi kimyasal ve fiziksel değişiklikler izlenmektedir. Yeni bağ dokusu ataşmanı sağlanarak cep derinliğinde azalma ise ekolojik çevrenin değişimi sağlanabilmektedir. Cerrahi olmayan periodontal tedavide amaç kök yüzeyinde yeni ataşmanın tutunabilmesini sağlamaktır (13). Bakteriyel artıkların uzaklaştırılması ve nekrotik sementin uzaklaştırılması için çok çeşitli aletler ve çeşitli tedavi protokolleri uygulanmaktadır. Konvansiyonel tedavide el aletleri ve ultrasonik aletler rutin olarak kullanılmaktadır. Bazı çalışmalarda konvansiyonel tedaviye ek olarak kullanılan Nd:YAG, Er:YAG, Er,Cr:YSGG ve diyod lazer uygulamalarının tedavinin başarısına olumlu etki olduğu savunulurken (14), bazılarında ise etkisiz olduğu savunulmuştur (15). Biz bu çalışmada lazer destekli periodontal tedavi sonrası oluşan kök yüzey değişikleri SEM ile incelemeyi amaçladık. Elde ettiğimiz sonuçlar Oliveire ve ark. ile uyumluydu. Oliveire ve ark. ve arkadaşları yaptığı çalışmada Er,Cr:YSGG lazer kullanmış ve lazer uygulanmış yüzeylerin daha düzensiz olduğunu gözlemlemişlerdir (16). Resim 1: Konvansiyonel tedavi periodontal tedavi sonrası kök yüzeyinin SEM görüntüsü (500X magnifikasyon) Resim 2: Konvansiyonel tedavi ve lazer uygulaması sonrası kök yüzeyinin SEM görüntüsü (500X magnifikasyon) Konvansiyonel tedaviye ek olarak kullanılan lazer uygulamalarında kullanılan lazer parametrelerinin morfolojik değişiklere neden olduğu bilinmektedir. Tin ve ark. Er,Cr:YSGG lazer kullanarak yaptıkları çalışmalarında lazeri farklı ayarlar da (0,5 W, 1 W, 1,5 W, 2 W) kullanmış ve bu değerlerde oluşan morfolojik değişikleri SEM ile incelemişlerdir. Lazer 2 W enerji ile kullanıldığında etkin bir kalkulus uzaklaştırması sağlanmış ancak kök yüzeyinde beraberinde belirgin morfolojik değişiklikler izlenmiştir. Bu nedenle her ne kadar 1 W kalkulus uzaklaştırma da, 2 W kadar başarılı olmasa da kök yüzeyinde değişikliklere neden olmaması nedeniyle daha uygun olduğu sonucuna varmışlardır (17). Hakkı ve ark. (13) yaptıkları çalışmada ise lazer grubunda izlenen kök yüzey değişikliklerinin puls süresine bağlı olabileceğini öne sürmüşlerdir. Ayrıca kök yüzeyinde oluşan morfolojik değişiklikler lazer tipine bağlı olarak da farklılıklar gösterebilmektedir. Kök yüzey düzleştirmesi için en uygun lazerlerden biri olan Er:YAG lazerin kök yüzey morfolojisi üzerine etkisini değerlendirdiğimiz bu çalışmamızda, Er:YAG lazerin, el aletleri ve ultrasonik cihazlar kullanılarak yapılan tedaviye göre daha fazla kök yüzey düzensizliğine yol açtığı sonucuna ulaştık. Ancak elde ettiğimiz bu sonuç kök yüzeyine kan hücrelerinin ya da fibroblast hücrelerinin tutunmasına engel teşkil edeceği anlamına gelmemektedir. Bolortuya ve ark. (18) dentin yüzeylerinde oluşan morfolojik değişiklikleri ve düzensizlikleri ölçerek değerlendirmiş ve 12. ve 24. saatler sonunda Er:YAG lazer uygulanan dentin yüzeylerine diğer gruplara göre daha fazla sayıda fibroblast

18 Lazer destekli kök yüzey düzleştirilmesi hücrelerinin tutunduğunu göstermiştir. Tsurumaki Jdo ve ark. (19) da ultrasonik cihazlar ve Er,Cr:YSGG kullanılarak yapılan tedaviler de küretlerle yapılan tedaviye göre çok daha fazla yüzey düzensizliği rastlanmış olmasına rağmen kan hücre adezyonu açısında gruplar arasında bir fark bulamamışlardır. SONUÇ Çalışmamızda yüzey düzensizliklerinin analizine dair bir değerlendirme olmamasına rağmen, SEM analizleri sonucu gruplar arasında yüzey düzensizliğinde belirgin farklılıklar elde edilmiştir. En az yüzey düzensizliği ve düzgün yüzeyler konvansiyonel tedavi ile elde edilmiş, lazer grubunda ise düzensizlik çok daha fazla olarak izlenmiştir. Konvansiyonel periodontal tedaviye ek olarak Er:YAG lazerin kullanılması ile zarar görmüş kök yüzeylerinin düzleştirilmesin de başlangıca göre kök yüzey düzensizliğinde azalma sağlansa da tek başına konvansiyonel tedavi ile çok daha pürüzsüz kök yüzeyleri elde edilebilmektedir. Bu çalışmada klinik bir öneride bulunabilmek ya da herhangi bir yargıya varabilmek için elde edilen sonuçları hücre adezyon testleri ile desteklememiz gerekmektedir. Çalışılan örnek sayısı yeterli olup, hücre adezyon testlerinin çalışma içinde yer almaması, bu çalışmanın en önemli limitasyonudur.

19 KAYNAKLAR 1. Lopes BM, Theodoro LH, Melo RF, Thompson GM, Marcantonio RA. Clinical and microbiologic follow up evaluations after non-surgical periodontal treatment. Periodontol 2010;81:682-691. 2. Herrero A, García-Kass AI, Gómez C, Sanz M, García- Nuñez JA. Effect of two kinds of Er:YAG laser systems on root surface in comparison to ultrasonic scaling: an in vitro study. Photomed Laser Surg 2010;28:497-504. 3. Tomasi C, Schander K, Dahlén G, Wennström JL. Short-term clinical and microbiologic effects of pocket debridement with an Er:YAG laser during periodontal maintenance. J Periodontol 2006;77:111-118. 4. Schwarz F, Sculean A, Rothamel D, Schwenzer K, Georg T, Becker J. Clinical evaluation of an Er:YAG laser for nonsurgical treatment of peri-implantitis: a pilot study. Clin Oral Implants Res 2005;16:44-52. 5. Pereira AN, Eduardo Cde P, Matson E, Marques MM. Effect of low-power laser irradiation on cell growth and procollagen synthesis of cultured fibroblasts. Lasers Surg Med 2002;31:263-267. 6. Fried D, Zuerlein MJ, Le CQ, Featherstone JD. Thermal and chemical modification of dentin by 9-11-microm CO2 laser pulses of 5-100-micros duration. Lasers Surg Med 2002;31:275-282. 7. Qadri T, Javed F, Poddani P, Tunér J, Gustafsson A. Longterm effects of a single application of a water-cooled pulsed Nd:YAG laser in supplement to scaling and root planing in patients with periodontal inflammation. Lasers Med Sci 2011;26:763-766. 8. De Mendonca AC, Maximo MB, Rodrigues JA, Arrais CA, de Freitas PM, Duarte PM. Er:YAG laser, ultrasonic system, and curette produce different profiles on dentine root surfaces: an in vitro study. Photomed Laser Surg 2008;26:91-97. 9. Theodoro LH, Haypek P, Bachmann L, Garcia VG, Sampaio JE, Zezell DM, et al. Effect of Er:YAG and diode laser irradiation on the root surface: morphological and thermal analysis. J Periodontol 2003;74:838-843. 10. Maruyama H, Aoki A, Sasaki KM, Takasaki AA, Iwasaki K, Ichinos S. The effect of chemical and/or mechanical conditioning on the Er:YAG laser-treated root cementum: analysis of surface morphology and periodontal ligament fibroblast attachment. Lasers Surg Med 2008;40:211-222. 11. Casarin RCV, Pinto FR, Sallum AW, Sallum EA, Nociti-Jr FM, Casati MZ. Assessment of ultrasonic root surface scaling with different power settings. Roughness evaluation. Braz Journal of Oral Sci 2006;17:996-1000. 12. Cobb CM. Laser in periodontics: a review of literature. J Periodontol 2006;77: 545-564. 13. Hakki SS, Korkusuz P, Berk G, Dundar N, Saglam M, Bozkurt B, et al. Comparison of Er,Cr:YSGG laser and hand instrumentation on the attachment of periodontal ligament fibroblasts to periodontally diseased root surfaces: an in vitro study. J Periodontol 2010;81:1216-1225. 14. Ishikawa I, Aoki A, Takasaki AA. Clinical application of Erbium:YAG laser in periodontology. J Int Acad Periodontol 2008;10:22-30. 15. Rotundo R, Nieri M, Cairo F, Franceschi D, Mervelt J, Bonaccini D, et al. Lack of adjunctive benefit of Er:YAG laser in non-surgical periodontal treatment: a randomized split-mouth clinical trial. J Clin Periodontol 2010; 37:526-533. 16. De Oliveira GJ, Sampaio JE, Marcantonio RA. Effects of Er,Cr:YSGG laser irradiation on root surfaces for adhesion of blood components and morphology. Photomed Laser Surg 2010; 28:751-756. 17. Ting CC, Fukuda M, Watanabe T, Aoki T, Sanaoka A, Noguchi T. Effects of Er,Cr:YSGG laser irradiation on the root surface: morphologic analysis and efficiency of calculus removal. J Periodontol 2007;78:2156-2164. 18. Bolortuya G, Ebihara A, Ichinose S, Watanabe S, Anjo T, Kokuzawa C, et al. Effects of dentin surface modifications treated with Er:YAG and Nd:YAG laser irradiation on fibroblast cell adhesion. Photomed Laser Surg 2012;30:63-70. 19. Tsurumaki Jdo N, Souto BH, Oliveira GJ, Sampaio JE, Marcantonio Júnior E, Marcantonio RA. Effect of instrumentation using curettes, piezoelectric ultrasonic scaler and Er,Cr:YSGG laser on the morphology and adhesion of blood components on root surfaces: a SEM study. Braz Dent J 2011;22:185-192.

20