THE INVESTIGATIONS OF SURFACE ACCURACIES OBTAINED FROM DIFFERENT DISTANCES WITH OPTECH ILRIS 3D LASER SCANNER

Benzer belgeler
THE EFFECT TO GEOREFERENCING ACCURACY OF CONTROL TARGETS IN TERRESTRIAL LASER SCANNING APPLICATIONS

Yersel Lazer Tarama Ölçmelerinde Doğruluk Analizi

MÜHENDİSLİK ÖLÇMELERİ UYGULAMASI (HRT4362) 8. Yarıyıl

OBJE YÜZEY RENKLERİNİN YERSEL LAZER TARAYICILARINA ETKİSİ THE EFFECT OF OBJECT SURFACE COLORS ON THE TERRESTRIAL LASER SCANNERS

YERSEL LAZER TARAYICILARIN TARAMA AÇISI VE MESAFESİNE BAĞLI OLARAK KONUM DOĞRULUĞUNUN ARAŞTIRILMASI

LAZER TARAMA YÖNTEMİ İLE ELDE EDİLEN ÜÇ BOYUTLU İÇ MEKÂN MODELLERİNİN COĞRAFİ BİLGİ SİSTEMLERİNDE KULLANIM OLANAKLARI

OBJE YÜZEY EĞİMLERİNİN YERSEL LAZER TARAYICILARIN KONUM DOĞRULUĞUNA ETKİLERİ

ÇATI KAFES SİSTEMLERİNİN LAZER TARAYICI YARDIMI İLE MODELLENMESİ

HACİM HESAPLAMALARINDA LASER TARAMA VE YERSEL FOTOGRAMETRİNİN KULLANILMASI

YÜZEYLERİN PÜRÜZLÜLÜK AÇILARININ LAZER TARAYICILAR YARDIMIYLA BELİRLENMESİ

INVESTIGATION OF ELEVATION CHANGE WITH DIFFERENT GEODETIC MEASUREMENT METHODS

YERSEL FOTOGRAMETRİK YÖNTEM İLE YERSEL LAZER TARAMANIN KARŞILAŞTIRILMASI VE DOĞRULUK ANALİZİ

YERSEL LAZER TARAMA VERİLERİNDE ÇEVRESEL VE OBJESEL NEDENLERDEN KAYNAKLANAN HATALAR

ARAZİ ÇALIŞMASI -1 DERSİ ELEKTRONİK ALETLERİN KONTROL VE KALİBRASYONU UYGULAMALARI

ÇELİK YAPILARDA DIŞ CEPHE GİYDİRMEYE YÖNELİK RÖLÖVE ÇALIŞMALARI SURVEY STUDIES FOR OUTSIDE FACING ON STEEL CONSTRUCTIONS

Onarge Teknoloji Medikal Sistemler Sanayi Ticaret Limited Þirketi Onarge Technology Medical Systems Industry Comm. Co. Ltd.

ARAZİ ÇALIŞMASI -1 DERSİ ELEKTRONİK ALETLERİN KONTROL VE KALİBRASYONU UYGULAMALARI

SPS ZOOM D Lazer Tarayıcı SPS ZOOM 300

Ölçme Bilgisi Jeofizik Mühendisliği Bölümü

TMMOB Harita ve Kadastro Mühendisleri Odası 12. Türkiye Harita Bilimsel ve Teknik Kurultayı Mayıs 2009, Ankara

Research On Using a Mobile Terrestrial Photogrammetric Mapping System For The Determination Of Object Volumes

MÜHENDİSLİK ÖLÇMELERİ UYGULAMASI (HRT4362) 8. Yarıyıl

5 İki Boyutlu Algılayıcılar

ÖZGEÇMİŞ. 1. Adı Soyadı : Halil ERKAYA. : Yenişehir Mah. Cumhuriyet Bulvarı, Orkide sok. No:1 Alibey Konakları F Blok D: PENDİK / İSTANBUL

YERSEL LAZER TARAMA YÖNTEMİNİN MİMARİ BELGELEMEDE KULLANILMASI

Bu proje Avrupa Birliği ve Türkiye Cumhuriyeti tarafından finanse edilmektedir. İLERİ ÖLÇME TEKNİKLERİ (CMM) EĞİTİMİ DERS NOTU

PİEZOELEKTRİK YAMALARIN AKILLI BİR KİRİŞİN TİTREŞİM ÖZELLİKLERİNİN BULUNMASINDA ALGILAYICI OLARAK KULLANILMASI ABSTRACT

A UNIFIED APPROACH IN GPS ACCURACY DETERMINATION STUDIES

COMPARISION OF CLASSIC RTK, NETWORK RTK AND TOTAL STATION TECHNIQUES IN DETERMINATION OF POINT POSITIONS

Yıldız Teknik Üniversitesi İnşaat Fakültesi Harita Mühendisliği Bölümü TOPOGRAFYA (HRT3351) Yrd. Doç. Dr. Ercenk ATA

MEVCUT GPS/NİVELMAN VERİ KÜMESİNİN JEOİT MODELLEME AÇISINDAN DEĞERLENDİRİLMESİ

ARAZİ ÖLÇMELERİ. Koordinat sistemleri. Kartezyen koordinat sistemi

3 DIMENSIONAL MODELLING OF LARGE OBJECTS IN OPEN-SPACE: A COMPARISON OF RECENT METHODOLOGIES IN GEOMATICS ENGINEERING

HİDROGRAFİK ÖLÇMELERDE ÇOK BİMLİ İSKANDİL VERİLERİNİN HATA ANALİZİ ERROR BUDGET OF MULTIBEAM ECHOSOUNDER DATA IN HYDROGRAPHIC SURVEYING

JEODEZİK VERİLERİN İSTATİSTİK ANALİZİ (Ölçüler Yöntemleri) Prof. Dr. Mualla YALÇINKAYA

YÜKSEKLİK ÖLÇÜMÜ. Ölçme Bilgisi Ders Notları

Veri toplama- Yersel Yöntemler Donanım

İnşaat Mühendisliğine Giriş İNŞ-101. Yrd.Doç.Dr. Özgür Lütfi Ertuğrul

THE INVESTIGATION ON A LOW COST TWO -DIMENSIONAL SEMI-AUTOMATIC LASER SCANNING SYSTEM

Dijital Fotogrametri

LIDAR VE YERSEL LAZER TARAYICI SİSTEMLERİ. Yersel Lazer Tarayıcı Hakkında Genel Bilgi

Dijital (Sayısal) Fotogrametri

Yükseklik Ölçme (Nivelman) Prof.Dr.Mustafa KARAŞAHİN

EĞİTİM - ÖĞRETİM YILI MÜHENDİSLİK FAKÜLTESİ / HARİTA MÜHENDİSLİĞİ EĞİTİM PLANI

Yersel Lazer Tarayıcılar ile 3 Boyutlu Modelleme

MAK 309 Ölçme Tekniği ve Değerlendirme. Temel Kavramlar

TMMOB Harita ve Kadastro Mühendisleri Odası Ulusal Coğrafi Bilgi Sistemleri Kongresi 30 Ekim 02 Kasım 2007, KTÜ, Trabzon

Bilgisayarla Fotogrametrik Görme

STATIC POSITIONING PERFORMED FROM DIFFERENT GNSS NETWORKS AND STATIONS INVESTIGATION IN ISTANBUL SCALE

PROJE RAPORU. - Prof. Dr. İrfan ŞİAP - Doç. Dr. Ünal UFUKTEPE

LCD 4 Fantomu Üzerinde Sayım ve Görüntüleme Dedektörleri Kullanılarak Yapılan Kontrast Ölçümlerinin Karşılaştırılması

Hakan AKÇIN* SUNU Ali ihsan ŞEKERTEKİN

ARAZİ ÖLÇMELERİ. Koordinat sistemleri. Kartezyen koordinat sistemi

ÖZET OTOMATİK KÖKLENDİRME SİSTEMİNDE ORTAM NEMİNİN SENSÖRLERLE HASSAS KONTROLÜ. Murat ÇAĞLAR

ARAZİ ÖLÇMELERİ. Temel Ödev I: Koordinatları belirli iki nokta arasında ki yatay mesafenin

SIVI YOĞUNLUKLARININ BİRİNCİL SEVİYEDE BELİRLENMESİNİ SAĞLAYAN ÖLÇÜM DÜZENEĞİ

OBRUK BARAJI DEFORMASYON ÖLÇMELERİ DEFORMATION MEASUREMENTS ON OBRUK DAM

ARAZİ ÖLÇMELERİ. Doğrultuya dik inme veya dik çıkma (Yan Nokta Hesabı) Dik İnmek. A Dik Çıkmak

MÜHENDİSLİK UYGULAMALARINDA KULLANILAN YERSEL LAZER TARAYICI SİSTEMLER USING THE TERRESTRIAL LASER SCANNER SYSTEMS FOR ENGINEERING APPLICATIONS

HAVACILIKTA TERSİNE MÜHENDİSLİK UYGULAMALARI. Özgecan YILDIZ 1

COMPARING THE PERFORMANCE OF KINEMATIC PPP AND POST PROCESS KINEMATICS METHODS IN RURAL AND URBAN AREAS

UZAYSAL VE DOLU GÖVDELİ AŞIKLARIN ÇELİK ÇATI AĞIRLIĞINA ETKİSİNİN İNCELENMESİ

HASSAS ORMANCILIK. Prof.Dr. Abdullah E. Akay. BTÜ Orman Fakültesi Orman Mühendisliği Bölümü Osmangazi-Bursa

M. Taner Aktaş, GISP : mtaktas@yahoo.com

KAYAÇ YÜZEYLERİ İÇİN YAKIN RESİM FOTOGRAMETRİSİ VE LAZER TARAMA TEKNİKLERİNİN KARŞILAŞTIRILMASI

Laser LAX 300 G. Kullanma kılavuzu

HASSAS MUTLAK KONUMLAMA TEKNİĞİ (PPP) İLE AĞ RTK KONUMLAMA TEKNİĞİNDEN ELDE EDİLEN YÜKSEKLİK BİLEŞENİNİN DOĞRULUK KARŞILAŞTIRMASI

İKİ BOYUTLU AĞLARDA AĞIRLIK SEÇİMİNİN DENGELEME SONUÇLARINA ETKİSİ VE GPS KOORDİNATLARI İLE KARŞILAŞTIRILMASI

GÖRÜNTÜSÜ ALINAN BİR NESNENİN REFERANS BİR NESNE YARDIMIYLA BOYUTLARININ, ALANININ VE AÇISININ HESAPLANMASI ÖZET ABSTRACT


Dijital (Sayısal) Fotogrametri

Araziye Çıkmadan Önce Mutlaka Bizi Arayınız!

Tanımlar, Geometrik ve Matemetiksel Temeller. Yrd. Doç. Dr. Saygın ABDİKAN Yrd. Doç. Dr. Aycan M. MARANGOZ. JDF329 Fotogrametri I Ders Notu

Yrd. Doç. Dr. Aycan M. MARANGOZ. BEÜ MÜHENDİSLİK FAKÜLTESİ GEOMATİK MÜHENDİSLİĞİ BÖLÜMÜ JDF329 FOTOGRAMETRİ I DERSi NOTLARI

RAYLI SİSTEMLERDE ÖLÇME TEKNİKLERİ VE DONANIMLARI

SULTANHANI KERVANSARAYI FOTOGRAMETRİK RÖLÖVE ALIMI VE ÜÇ BOYUTLU MODELLEME ÇALIŞMASI

4. Hafta. Y. Doç. Dr. Himmet KARAMAN

Genel Bilgiler FLI MAP. Koridor Tipi Çalışmalar. Geniş Alan Çalışmaları

Teşekkür. BOĞAZİÇİ UNIVERSITY KANDİLLİ OBSERVATORY and EARTHQUAKE RESEARCH INSTITUTE GEOMAGNETISM LABORATORY

Yrd. Doç. Dr. Aycan M. MARANGOZ. BEÜ MÜHENDİSLİK FAKÜLTESİ GEOMATİK MÜHENDİSLİĞİ BÖLÜMÜ JDF329 FOTOGRAMETRİ I DERSi NOTLARI

Hava Fotogrametrisi ve Jeodezik Yöntemler ile Sayısal Yükseklik Modeli Üretimi: Erzurum Aksu Köyü Örneği

Dijital (Sayısal) Fotogrametri

Lazer-obje (hedef) etkileşimi-yüzey eğim ve pürüzlülüğü

2. Hafta. Y. Doç. Dr. Himmet KARAMAN

RTK GPS VE YARDIMCI SENSÖR ÖLÇMELERİ İLE YÜKSEK YAPI DAVRANIŞLARININ ANALİZİ

DETERMINATION OF VELOCITY FIELD AND STRAIN ACCUMULATION OF DENSIFICATION NETWORK IN MARMARA REGION

3D INFORMATION EXTRACTION FROM DIGITAL AERIAL IMAGES WITH COMPUTER VISION AND PHOTOGRAMMETRIC SPACE INTERSECTION

We measure it. testo 835 Isıtma-soğutma ve endüstri sektörleri için hızlı, güvenilir infrared ölçüm cihazı.

A RESEARCH ON DIFFERENT QUANTITY CHANGES ON GPS MEASUREMENTS IN RESPECT OF MEASUREMENT DURATION

ARAZİ ÖLÇMELERİ. Coğrafik Objenin Alan Bilgisinin Bulunması

2. Basınç ve Akışkanların Statiği

YALOVA ÜNİVERSİTESİ MÜHENDİSLİK FAKÜLTESİ ENERJİ SİSTEMLERİ MÜHENDİSLİĞİ BÖLÜMÜ UYGULAMALI MÜHENDİSLİK MODELLEMESİ

TOPOĞRAFYA Yüksekliklerin Ölçülmesi Nivelman Yöntemleri

YTÜ Makine Mühendisliği Bölümü Mekanik Anabilim Dalı Genel Laboratuvar Dersi Eğilme Deneyi Çalışma Notu

ÜÇ BOYUTLU ŞEHİR MODELLERİNİN VERİ YAPISI VE KULLANIM ÖZELLİKLERİ

TOPOĞRAFYA Yüksekliklerin Ölçülmesi Nivelman Yöntemleri

KOMPOZİT MALZEMELERİN TERMAL ANALİZİ

1. GİRİŞ. Şekil 1. Kızkalesi nin konumu

Akreditasyon Sertifikası Eki (Sayfa 1/20) Akreditasyon Kapsamı

daha çok göz önünde bulundurulabilir. Öğrencilerin dile karşı daha olumlu bir tutum geliştirmeleri ve daha homojen gruplar ile dersler yürütülebilir.

Transkript:

OPTECH ILRIS 3D LAZER TARAYICISI İLE FARKLI MESAFELERDEN ELDE EDİLEN YÜZEYLERİN DOĞRULUKLARININ ARAŞTIRILMASI K. GÜMÜŞ 1, H.ERKAYA 2 1 Niğde Üniversitesi, Mühendislik Fakültesi, Harita Mühendisliği Bölümü, Ölçme Tekniği Anabilim Dalı, Niğde, kgumus@nigde.edu.tr 2 Okan Üniversitesi, Mühendislik Fakültesi, Geomatik Mühendisliği Bölümü, İstanbul, halil.erkaya@okan.edu.tr Özet Mühendislik Ölçmeleri uygulamalarında ve projelerinde, konumun, boyutların, şeklin sayısal ortamda kayıt edilmesi, belgelenmesi ve verilerin analizi temel işlem adımlarıdır. Gelişen üç boyutlu ölçme yöntemleriyle, planın tamamının veya bir bölümünün verileri doğrudan elde edilebilmektedir. 3 boyutlu ölçüm yapabilmek için birçok yöntem vardır. Günümüzde jeodezik ölçüm tekniği olarak kullanılan yersel lazer tarayıcılar üzerine kapsamlı araştırmalarda ciddi gelişmeler görülmüştür. Birçok ölçme çalışmalarında yersel tarayıcıların kullanılması ve bir sektör haline gelmesi, lazer tarayıcıların önemini vurgulamaktadır. Bu çalışmanın amacı, Optech ILRIS 3D lazer tarayıcısı ile farklı mesafelerden elde edilen yüzey doğruluklarının araştırılması üzerinedir. Bu çalışma, YTÜ Davutpaşa Kampüsünde bulunan 300 m uzunluğundaki EDM Kalibrasyon bazında gerçekleşmiştir. EDM Kalibrasyon bazında sırasıyla 40, 120, 220, 280 ve 300 m uzaklıktaki pilye noktalarından yersel lazer tarama ile elde edilen farklı objelere ait yüzey modellerinin doğruluğu, Leica TPS 1201+ Total station ile elde edilen yüzey modelleri ile karşılaştırılmıştır. Yüzey olarak boyutları 104.5*104.5 cm olan kare şeklindeki alüminyum obje ile 1 m çapında çanak şeklindeki bombeli obje kullanılmıştır. Bu objeler, doğrusal hareket sağlayan özel tasarlanan bir aparat üzerine monte edilerek, EDM pilyeleri üzerine merkezlendirilmiştir. Taranan objeye ve farklı mesafelere bağlı yüzey modellerinin doğruluklarının değiştiği belirlenmiştir. Anahtar Kelimeler: Yersel lazer Tarayıcı, yüzey modelleri, doğruluk, karşılaştırma Abstract THE INVESTIGATIONS OF SURFACE ACCURACIES OBTAINED FROM DIFFERENT DISTANCES WITH OPTECH ILRIS 3D LASER SCANNER The position, dimension, recorded in the form of digital media, documentation, and analysis of data are fundamental process steps in the Engineering Surveying applications and projects. The entire plan or a portion of the data can be obtained directly by a developing three-dimensional measuring method. There are many methods to make three-dimensional measurements. Nowadays the extensive research on terrestrial laser scanners used as geodetic measurement technology has seen significant developments. The use of terrestrial scanner and being a sector in many measurement studies emphasize the importance of laser scanners. The aim of this study is to investigate the surface accuracies obtained from different distances with Optech ILRIS 3D laser scanner. This work has been realized on the base of EDM calibration in 300 m length in YTÜ Davutpaşa Campus. The accuracy of the surface model of the different objects obtained by terrestrial laser scanning was compared with the surface model obtained by Leica TPS 1201+ Total station from the bent bar points away from respectively 40, 120, 220, 280 and 300 m in the EDM Calibration Base. Square-shaped aluminum

2 objects with dimensions of 104.5 * 104.5 m and curved bowl-shaped object 1 m in diameter is used as a surface. These objects mounted on a specially designed apparatus providing linear motion, it is centered on the EDM bent bars points. The change of accuracy of surface models was determined depending on scanned objects and different distances. Keywords: Terrestrial laser scanner, surface models, accuracy, comparison. 1. Giriş Günümüzde, Yersel lazer tarama (TLS - Terrestrial Laser Scanning / Scanner) uygulamaları, dünyada ön plana çıkmaya ve hızla gelişmeye başlamıştır. Yersel lazer sistemlerinden elde edilen bilgiler gerçek ile uyumludur. 3 boyutlu geometrik ve görsel bilgiler, hızlı olarak lazer tarama sistemleri ile elde edilmektedir. TLS ile ulaşılması zor, tehlikeli obje ve alanlardaki tüm detaylar tek seferde toplanabilmektedir. Teknoloji ve bilgisayarlardaki gelişmeler, bilgi edinimi hızı, menzil doğruluğu ve güvenirliği, boyut ve maliyet azalması vb. etkiler TLS nin kullanımını gittikçe artırmaktadır. Bilimsel amaçlı araştırmalar için yapılan çalışmalar, doğruluk ve duyarlılık üzerine yoğunlaşarak yürütülmektedir. Bu araştırmaların çoğu, tarayıcı obje arasındaki mesafenin etkisi, lazer ışınının geliş açısı, taranan obje veya nesnenin rengi ve malzemenin cinsi, lazer ışınının dönüş yoğunluğu ve ışın uzaklaşması üzerinedir. TLS üzerine yapılan birçok akademik ve bilimsel araştırma, yayın ve bu konu hakkında bilinen birçok kitap vardır. Lazer uzunluk ölçme teknolojisinin teorik temelleri Ready (1978), Hovanessian (1988), Jelalian (1992), Marshall (1985), Hebert ve Krotkov (1985), Resthetyuk (2006) da açıklanmıştır. Uçuş zamanını (TOF-Time Of Flight) içeren, lazer uzunluk ölçme teknikleri üzerine çok iyi ve kapsamlı bir inceleme Reshetyuk (2006) da verilmiştir. Hebert ve Krotkov (1985) de tarayıcıların doğruluk araştırmalarını yapılmış ve kalibrasyon sonuçları rapor edilmiştir. Lazer tarayıcı aletlerinin doğruluğunu etkileyen faktörler hakkındaki bir araştırma, Hancock (1999) da yapılmıştır. Bu çalışmanın amacı, Optech ILRIS 3D lazer tarayıcısı ile farklı mesafelerden elde edilen yüzey doğruluklarının araştırılması üzerinedir. 300 m uzunluğundaki EDM Kalibrasyon bazında sırasıyla 40, 120, 220, 280 ve 300 m uzaklıktaki pilye noktalarından yersel lazer tarama ile elde edilen farklı objelere ait yüzey modellerinin doğruluğu, Leica TPS 1201+ Total station ile elde edilen yüzey modelleri ile karşılaştırılmıştır. Tarana objeye ve mesafeye bağlı yüzey modellerinin doğrulukları araştırılmıştır. 2. Yöntem Bu çalışma, YTÜ Davutpaşa Kampüsü, Fen Edebiyat Fakültesi bahçesinde bulunan 300 m uzunluğundaki EDM Kalibrasyon bazında gerçekleşmiştir. Buradaki noktalar 1. Nolu referans pilyesinden sırasıyla 40, 120, 220, 280 ve 300 m uzaklıkta toplam 6 pilye noktasından oluşmaktadır. Pilyelerin konumları ve aradaki uzaklıklar 1+1.5 ppm lik Leica TPS 1201+ Total station ile hassas bir

3 şekilde ölçülerek önceden belirlenmiştir. Yüzey karşılaştırılması için, boyutları 104.5*104.5 cm olan kare şeklindeki alüminyum obje ile 1 m çapında çanak şeklindeki bombeli obje hedef olarak kullanılmıştır (Gümüş, 2014). Özel olarak tasarlamış bu hedefler Şekil 1 de gösterilmiştir. Şekil 1: Özel tasarlanmış referans objeler (Gümüş,2014) Yine pilyeler üzerinde bu hedeflerin hassas şekilde doğrusal olarak hareket ettirilmesi için, pilye üzerine monte edilebilen 0.1 mm kaydırma hassasiyetine sahip özel tasarlanmış bir aparat kullanılmıştır (Şekil 2). Yüzey karşılaştırılması amacıyla bu hedefler, pilye üzerine merkezlendirilen aparat üzerine monte edilmiştir. Tablo 1 de tasarlanan aparatın hazırlanmasında kullanılan donanımlar gösterilmiştir (Gümüş, 2014). Tablo 1: Doğrusal hareket sistemin yapımında kullanılan donanımlar 109-5200 Q8 Blok Yatak 910 Mm. Strok MLS305-TTL-2-5M Digital Koordinat Okuma Cetveli 836 Mm ALC94UNİ 220 VAC TTL Girişli Ekran İmalat Parçaları ve Bağlantı Elemanları Modül Akuplasyon Bağlantı Elemanları Şekil 2: Doğrusal Hareket Sistemi Tasarımı (Gümüş, 2014) Farklı mesafelerden yapılan taramaların kendi belirlediğimiz koordinat sistemine (tarama yönü y ekseni olacak şekilde) dönüşümü için hedeflerin kurulu olduğu pilyeler çevresine kontrol noktaları yerleştirilmiştir. Mesafeye bağlı olarak yapılan taramalar bu objeleri ve kontrol noktalarını da içerisine

4 alacak şekilde gerçekleştirilmiştir. Uygulamanın gerçekleştiği kalibrasyon bazının 1 numaralı Pilye noktasına bu referans objeler, nokta üzerine merkezlenecek ve doğrusal yönde tarama yönüne düşey doğrultu oluşturulacak şekilde aparat üzerine hassas bir şekilde konumlandırılmıştır (Şekil 3). Şekil 3: Referans objelerin ve hedeflerin pilye üzerindeki konumları(gümüş, 2014). Aparatın tarama yönüne göre yatay ve düşey yöndeki doğrultusu hassas su terazisi ile kontrol edilmiştir. Optech ILRIS 3D lazer tarayıcısı, bazın pilye1 den itibaren 40 m, 120 m, 220 m, 280 m ve 300 m de bulunan pilye noktalarına kurulmuştur. Referans yüzeyler için Total Station ile EDM bazının 2 nolu pilye noktasında tarama modunda referans objelere ölçüler gerçekleştirilmiştir. Şekil 4: Lazer tarayıcının ve Total Station nın Pilyeye kurulumu (Gümüş, 2014). Çevresel koşulların etkisini yok etmek için aynı ortam koşullarında taramalar yapılmış ve ortamın sıcaklık, basınç ve nem değerleri uygulamalar boyunca kaydedilmiştir. Taranan obje yüzeyi düz ve materyal olarak lazer ışının yayılım ve saçılma etkisine aynı derecede etki etmektedir. Total Station ile Pilye 2 den ölçülen referans obje yüzeyleri ile Farklı mesafelerden tarayıcıdan elde edilen yüzeyler karşılaştırılmıştır. Yüzeylerin karşılaştırma yönü, aynı zamanda noktalar arası uzaklığı gösteren koordinat ekseni yönü (y ekseni) seçilmiştir (Şekil 5).

5 Şekil 5: EDM bazındaki yüzey karşılaştırma yönü (Gümüş, 2014). 3. Sonuç ve Öneriler Yüzey eşleştirmesi yapmak için yersel ölçmelerden ve lazer taramalardan elde edilen veriler kendi belirlediğimiz koordinat sistemine dönüştürülmüştür. Total Station dan elde edilen ölçümlerden her iki referans objesi için yüzey modelleri oluşturulmuştur. Bu yüzeyler referans alınarak taramalardan elde edilen nokta bulutları arasında y ekseni yönünde karşılaştırmalar yapılmıştır. Y ekseni doğrultusu, tarayıcı ve objeler arasındaki uzaklığı belirten EDM bazındaki pilyeler arasındaki ölçme doğrultusudur. Şekil 5 de kare ve bombe şeklindeki obje için total Station dan oluşturulan yüzey modeli ve tarayıcıdan elde edilen nokta bulutları görülmektedir. Burada, referans yüzey ile nokta bulutları x ve z koordinat ekseni yönünde çakıştırılıp, y koordinat ekseni yönündeki farkları belirlenmiştir. Buradaki amaç, faklı mesafelerde elde edilen taramalarda elde edilen uzunluk ölçme doğruluğun mesafeye ve yüzey eşleştirmeye göre değişip değişmediği belirlemektir. Şekil 5: Referans yüzey modelleri ve yüzey eşleştirmeden elde edilen farklar (Gümüş, 2014) Bu şekilde 40 m, 120 m, 220 m, 280 m ve 300 m den Optech ILRIS 3D ye Pilye 1 de bulunan referans objelere taramalar gerçekleştirilmiştir. Yüzey eşleştirme işlemleri yapılarak kare ve bombe objeler için, y koordinat ekseni yönünde farklar bulunmuştur. Farkların istatiksel değerleri, Tablo 2 ve Tablo 3 de verilmiştir (Gümüş, 2014).

6 Tablo 2: Kare obje için mesafeye bağlı bulunan istatiksel değerler (m) Tablo 3: Bombe obje için mesafeye bağlı bulunan istatiksel değerler (m) Şekil 6 da ise mesafeye bağlı elde edilen yüzey farkların standart sapma karşılaştırmaları verilmiştir. Bu karşılaştırmada standart sapma değerlerinin mesafeye bağlı ve taranan obje yüzeyine bağlı olarak değiştiği görülmektedir. Mesafe ile elde edilen standart sapma değişkenleri arasındaki ilişki Şekil 6 da gösterilmiştir (Gümüş, 2014).

7 Teşekkür Şekil 6: Mesafeye bağlı elde edilen yüzey farkların standart sapmaları (m) Bu çalışmaya destek sağlayan YTÜ Bilimsel Araştırma Projeleri Koordinatörlüğüne ve Lazer tarayıcıyı temin ettiğimiz BİMTAŞ AŞ. Genel Müdürlüğüne teşekkür ederiz. Kaynaklar Reshetyuk, Y., (2006), Investigation and calibration of pulsed time-of-flight terrestrial laser scanners, Licentiate thesis in Geodesy Royal Institute of Technology (KTH) Department of Transport and Economics Division of Geodesy. Ready, J.F., (1978), Industrial applications of lasers. Academic Press, New York San Francisco London. Hovanessian, S.A., (1988), Introduction to sensor systems. Artech House, Norwood, MA, USA. Jelalian, A.V., (1992, Laser Radar Systems. Artech House, Boston London Marshall, G.F., (ed) (1985), Laser beam scanning: opto-mechanical devices, systems, and data storage optics. Marcel Dekker, New York. Hebert, M., ve Krotkov, E., (1992). 3D Measurements From Imaging Laser Radars: How Good Are They? Image And Vision Computing, Vol. 10, No. 3, Pp. 170 178. Hancock, J.A., (1999). Laser Intensity-Based Obstacle Detection and Tracking, Doctoral Dissertation, Technical Report CMU-RI-TR-99-01, Robotics Institute, Carnegie Mellon University. Gümüş, K., (2014), Yersel Lazer Tarayıcıların Doğruluk Araştırması ve Mühendislik Yapılarında Kullanılabilirliği: Oymapınar Barajı Örneği, Doktora Tezi, YTÜ- FBE Harita Mühendisliği Anabilim Dalı.