G R PLAZMA KES M NDE UZUN YILLAR BOYUNCA ED N LEN DENEY M BU PROSES N ENDÜSTR DE VER ML B R EK LDE KULLANILAB LECE N GÖSTERM T R. GEREKEN D KKAT VE ÖZENLE KULLANILDI I TAKT RDE BU PROSES TÜM UYGULAMALARDA GÜVENL D R. ANCAK, BU KONUDA A A IDA YER ALAN PROSEDÜRLERE HARF YEN R AYET ED LMES ÖNER L R. D KKAT ED LMES GEREKEN GENEL KONULAR PLAZMA ARK KES M LEMLER NDE OPERATÖRÜN YARALANMASINI ÖNLEMEK Ç N ÖNLEM ALINMASINI GEREKT REN DÜZEYLERDE DUMAN, SES VE ULTRAV YOLE RADYASYONU MEYDANA GEL R. YANIKLARIN ÖNLENMES PLAZMA ARKI ÇOK DDETL ULTRAV YOLE RADYASYONU ÜRET R VE BU RADYASYON T P K YÜKSEK AKIMLI KAYNAK ARKLARIYLA AYNI DDETTED R. BU RADYASYON GÖZLERE VE C LDE ZARAR VEREB L R. OPERATÖR TORÇA YAKLA TIKÇA, MARUZ KALMA DÜZEY HIZLA ARTAR. OPERATÖRÜN VE ARKIN YAKININDA ÇALI AN HERKES N UYGUN KORUYUCU G YS LER G YMES VE KORUYUCU EK PMANLAR KULLANMASI GEREK R. KORUNMAK Ç N KAYNAK LEMLER SIRASINDA KULLANIM AMACYLA TASARLANMI UZUN ELD VENLER, EMN YET AYAKKABILARI VE B R KASK GEREKL D R. VÜCUDUN AÇIKTA KALAN YERLER N KAPATAN YANMAZ G YS LER VE KIVILCIM YA DA CÜRUF G RMES N ÖNLEYECEK PAÇALARI AÇIK OLMAYAN PANTOLON G Y LMES ÖNER L R. OPERATÖRÜN GÖZLER N N RADYASYONDAN VE UÇU AN KIVILCIMLAR YA DA SICAK METAL PARÇALARINDAN KORUNMASI Ç N YANLARI KAPALI KAYNAK GÖZLÜKLER TAKILMALIDIR. KES M ALANININ ULTRAV YOLE RADYASYONUNUN YANSIMASINI YA DA LET M N AZALTACAK EK LDE HAZIRLANMASI ÖNER L R. YANSIMAYI AZALTMAK Ç N DUVARLAR VE D ER YÜZEYLER KOYU RENKLERE BOYANMALIDIR. GEREKS Z ULTRAV YOLE LET M N ÖNLEMEK Ç N KORUYUCU EKRANLAR VEYA PERDELER MONTE ED LEB L R. ZEH RL DUMANLAR OPERATÖRÜN VE ÇEVREDEK D ER K LER N PLAZMA ARK KES M SIRASINDA ORTAYA ÇIKMASI MUHTEMEL ZEH RL DUMANLARA MARUZ KALMAMASI Ç N GEREKL ÖNLEMLER ALINMALIDIR. BAZI KLORLU SOLVENTLER ULTRAV YOLE RADYASYONU ALTINDA DEKOMPOZE OLARAK FOSGEN GAZI ÜRET R. BU SOLVENTLER N PLAZMA ARK KES M EK PMANI LE KES LEN MALZEMELER ÜZER NDE KULLANILMAMASINA D KKAT ED LMEL D R. BU SOLVENTLERE A T KAPLAR VE GRES ÇIKARMADA KULLANILAN D ER MADDELER PLAZMA ARK LEM N N YAPILDI I ALANDAN UZAKLA TIRILMALIDIR. KUR UN, KADM YUM, Ç NKO, CIVA VE BER LYUM KAPLI YA DA BU MADDELER ÇEREN METALLER PLAZMA ARKI LE KES LD NDE ZARARLI KONSANTRASYONLARDA ZEH RL DUMAN ÜRETEB L R. ÇALI MA ALANINDAK HAVANIN DI ARI ATILMASI Ç N GEREKL TERT BAT SA LANMALI YA DA OPERATÖR B R SOLUNUM C HAZI YA DA HAVA BESLEMEL B R BA LIK G B TAZE HAVA SA LAYACAK ÖZEL B R TEÇH ZAT G YMEL D R. ZEH RL DUMAN ÜRETEN MADDELERLE KAPLI METALLER: 1) KES M LEM NDEN ÖNCE KAPLAMA ÇIKARILMADI I, 2) ÇALI MA ORTAMI YETERL DÜZEYDE HAVALANDIRILMADI I, VEYA
3) OPERATÖRE TEM Z HAVA SA LAYAN TEÇH ZAT VER LMED SÜRECE KES LMEMEL D R. YETERL HAVALANDIRMA YA DA SOLUNUM C HAZI SA LANMAMI KAPALI MEKANLARDA ÇALI MAYIN. YANGINDAN KORUNMA PLAZMA ARK KES M LEM NDE SICAK METAL, KIVILCIM VE CÜRUF OLU TU UNDAN, MEYDANA GELEB LECEK HERHANG B R YANGINI VE/VEYA PATLAMAYI ÖNLEMEK Ç N GEREKL ÖNLEMLER ALINMALIDIR. KES M ALANINDA BULUNAN TÜM YANICI MALZEMELER EN AZ 10 M UZA A GÖTÜRÜLMEL D R. KES M LEM N N YAPILACA I ALANDA UYGUN YANGIN SÖNDÜRME C HAZLARININ BULUNMASI GEREK R. Ç NDE DAHA ÖNCE ZEH RL VEYA POTANS YEL PATLAYICI MADDELER BULUNAN BO KAPLARI KES NL KLE PLAZMA LE KESMEY N. TOZ, YANICI GAZ YA DA YANICI SIVI BUHARLARININ (BENZ N G B ) YO UN OLARAK BULUNDU U ATMOSFERDE KES NL KLE PLAZMA KES M YAPMAYIN. BASINÇLI GAZ EK PMANLARI BASINÇLI GAZ EK PMANLARI VE TÜPLER LE LEM ÖNLEMLER ALINMALIDIR. YAPILIRKEN GEREKL A. BASINÇ REGÜLATÖRLER PLAZMA EK PMANININ ÇALI TIRILMASINDA KULLANILAN TÜM REGÜLATÖRLER Y ÇALI IR DURUMDA TUTULMALIDIR. HATALI EK PMAN C HAZLARDA HASARA YA DA OPERATÖRÜN YARALANMASINA NEDEN OLAB L R. HATALI EK PMAN MALATÇININ TES SLER NDE, E T ML ONARIM TEKN SYENLER TARAFINDAN ONARILMALIDIR. ASLA REGÜLATÖRÜ, KULLANIMI Ç N AMAÇLANAN GAZDAN BA KA B R GAZ Ç N KULLANMAYIN. ASLA SIZDIRAN, A IRI SÜNME GÖSTEREN VEYA HERHANG B R EK LDE F Z KSEL HASAR GÖRMÜ OLAN REGÜLATÖRLER KULLANMAYIN. ASLA B R REGÜLATÖRÜ YA VEYA GRES LE YA LAMAYA ÇALI MAYIN. B. TÜPLER BASINÇLI GAZ TÜPLER EMN YET STANDARTLARINA GÖRE TA INMALI VE KULLANILMALIDIR. ASLA F Z KSEL HASARI BULUNAN VEYA SIZDIRAN TÜPLER KULLANILMAMALIDIR. ASLA D K DURMAYAN VE YER NE TESP T ED LMEM OLAN TÜPLER KULLANILMAMALIDIR. ASLA KORUYUCU VANA KAPA I TAKILI OLMAYAN TÜPLER YER NDEN ALINMAMALI VEYA TA INMAMALIDIR. ASLA TÜPÜ VEYA Ç NDEK MADDEY ESAS AMACINDAN BA KA B R AMAÇLA KULLANMAYIN. ASLA B R TÜPÜ YA VEYA GRES LE YA LAMAYA ÇALI MAYIN. ASLA KAYNAK VEYA KES M ARKLARI G B ELEKTR K KAYNAKLARINI TÜPLE TEMAS ETT RMEY N. ASLA TÜPLER A IRI ISIYA, KIVILCIMA, CÜRUF VEYA AÇIK ALEVE MARUZ BIRAKMAYIN, AKS TAKT RDE TÜPLER YIRTILAB L R. ASLA ARIZALI VANALARI ONARMAYA ÇALI MAYIN. BU TÜPLER TEDAR KÇ YE GER GÖNDER N. C. HORTUM PLAZMA ARK KES M S STEMLER NDE KULLANILAN GAZ HORTUMLARINDA A A IDA BEL RT LEN RENK KODLARI GEÇERL D R:
YE L OKS JEN S YAH NERT GAZLAR VE HAVA ASLA YE L RENKL OKS JEN HORTUMUNU BA KA B R GAZ Ç N KULLANILMAYIN. HATALI KULLANIM YA DA KIVILCIM VEYA AÇIK ALEV NEDEN YLE ZARAR GÖRMÜ OLAN HORTUMLARI DE T R N. HORTUMLARI KIRILMAYACAK EK LDE SER N. FAZLA HORTUMU KANGAL HAL NE GET R N VE ZARARA YOL AÇMAMASI VEYA ÇALI ANLARIN TAKILMAMASI Ç N KENARA ÇEK N. HORTUMU DÜZENL OLARAK KAÇAK, A INMA, GEV EK BA LANTI YA DA D ER HASARLAR AÇISINDAN KONTROL ED N. HASARI ÖNLEMEK, BASINÇ DÜ MES N ENGELLEMEK VE AKI HACM N KISITLAMAMAK Ç N HORTUM UZUNLUKLARINI M N MUM DÜZEYDE TUTUN. ELEKTR K OKUNUN ÖNLENMES PLAZMA ARK KESME EK PMANI PLAZMA ARKINI BA LATMAK Ç N YÜKSEK AÇIK DEVRE GER L M KULLANIR. NORMAL YÜK GER L MLER D ER TÜR KAYNAK EK PMANLARINDAN DAHA YÜKSEKT R. BU EK PMANI ÇALI TIRIRKEN YA DA SERV S YAPARKEN D KKATL OLUNMALIDIR. A. G R BA LANTILARI EK LDE GÖSTER LD G B S GORTALANMI, DUVARA MONTEL B R AYIRMA ALTER TEM N ED LMEL D R. ELEKTR K KABLOSU, KILIFINDA HASAR VEYA ÇATLAMA OLUP OLMADI I AÇISINDAN SIK SIK MUAYENE ED LMEL VE HASARLANMI SE DERHAL DE T R LMEL D R. B. TOPRAKLAMA B.1 G R GÜCÜ: ANA KABLO DONANIMININ TOPRAK KABLOSUNU (SARI/YE L) ETK NL N KONTROL EDEREK S STEM TOPRAK HATTINA BA LAYIN. D RENÇ NEDEN YLE ISI OLU MASINI ÖNLEMEK Ç N TÜM BA LANTILARIN SIKI OLMASINA D KKAT ED N. B.2 ÇIKI : S STEM TOPRAK MANDALI YAPILAN E YA DA TEZGAHA TAKILIR. TÜM BA LANTILARIN SIKI OLMASINA D KKAT ED LMEL D R. TEZGAH Y B R YER ALTI TOPRAK HATTINA BA LANMALIDIR. C. K SEL KORUNMA OPERATÖRÜN VÜCUDU VE G YS LER KURU TUTULMALIDIR. BU EK PMAN KULLANILIRKEN YA YÜZEYLERDE DURULMAMALI, BU YÜZEYLERE OTURULMAMALI YA DA YATILMAMALIDIR. ASLA ELEKTR K OKUNA KAR I GEREKL ÖNLEMLER ALINMADAN NEML YA DA ISLAK ALANLARDA ÇALI ILMAMALIDIR. TORÇA, KÜÇ KAYNA INA VEYA S STEME SERV S BA LANTILARINA SERV S YAPMADAN ÖNCE ELEKTR KES N. ELEKTR K KABLOLARI, TORÇ YA DA TORÇ KABLOLARI HASARLI SE, S STEM ASLA ÇALI TIRMAYIN. EMN YET C HAZLARI - EK PMANA YA DA OPERATÖRE ZARAR GELMES N ÖNLEYEN UYGUN EMN YET TEÇH ZATI LE DONATILMI TIR. - EMN YET C HAZLARININ BA LANTILARINI KISA DEVRE YA YAPARAK YA DA KESEREK BU C HAZLARA HATALI TEMASTAN KAÇININ.
- GEREK OPERATÖR GEREKSE D ER K LER Ç N ÇOK TEHL KEL OLACA INDAN, GÜÇ KAYNA INI EMN YET C HAZLARI OLMADAN KULLANMAYIN. TÜM ELEKTR K BA LANTILARI UYGUN ZOLASYON MADDELER LE KORUNMALIDIR. D KKAT: TÜM EMN YET C HAZLARI PER YOD K OLARAK KONTROL ED LMEL VE ARIZA DURUMUNDA DERHAL DE T R LMEL D R. KULLANICIYLA LG L EMN YET KURALLARI ELEKTR K ARKI I IK VE ISI EKL NDE B R D Z ELEKTROMANYET K DALGADAN OLU MAKTADIR. BU EM SYONLAR AYNI ZAMANDA NSAN GÖZÜ TARAFINDAN GÖRÜLMEMEKLE B RL KTE, NSAN Ç N ZARARLI OLAN MORÖTES VE KIZILÖTES DALGALAR EKL NDE DE OLMAKTADIR. BU EM SYONLARLA TEMAS ETMEMEK Ç N A A IDA YER ALAN KES N KURALLARA R AYET ED LMES GEREK R: MORÖTES VE KIZILÖTES EM SYONLARINA EN ÇOK MARUZ KALAN GÖZLERDE KONJONKT V T, RET NA YANIKLARI YA DA, DAHA DA KÖTÜSÜ GÖRME KAPAS TES NDE AZALMA MEYDANA GELEB L R. AYRICA, BU EM SYONLARA MARUZ KALAN C LT AZ YA DA ÇOK C DD YANIKLARDAN ETK LENEB L R. DOLAYISIYLA, ARK KAYNA I YAPMADAN ÖNCE, BU TEHL KELERDEN KAÇINAB LECEK YETERL DONANIMA SAH P OLUNMASI GEREK R. BU ÇALI MA Ç N UYGUN DONANIM A A IDAK ELEMANLARDAN OLU MAKTADIR: 1) DER ELD VEN 2) DER ÖNLÜK 3) TOZLUK (GET R) 4) EMN YET AYAKKABISI 5) TÜM YÜZÜ KAPLAYAN, RADYASYONU F LTRE EDEN VE I IK DDET N AZALTAN KORUMA CAMLI (AD AKT N K CAM) KORUYUCU MASKE. AD AKT N K CAMI GÖRÜ ALANINI KISITLAYAN NKANDESEN PART KÜLLERDEN KORUMAK Ç N AD AKT N K CAMIN ÖNÜNE EFFAF B R CAM KONULMASI YARARLI OLUR. CAMLAR TEM Z TUTULMALI VE KIRILDI I YA DA ÇATLADI I TAKT RDE DERHAL DE T R LMEL D R. ELEKTR K ARKINA ASLA MASKES Z OLARAK BAKMAYIN. EMN YET PROBLEMLER ELEKTR K ARKI LE SINIRLI DE LD R. BA KA PROBLEMLER HEM B Z HEM DE BA KALARI Ç N TEHL KEL OLAB L R. ÖRNE N: A) MONTAJ, FIRÇALAMA VE ÇEK ÇLEME LEMLER SIRASINDA GÖZLER Ç N ÇOK TEHL KEL OLAN PARÇALAR KOPAB L R. BU DURUMDAN KAÇINMAK Ç N DA MA GÖZLÜK YA DA EFFAF KORUYUCULAR TAKILMALIDIR. ELEKTR K ARKINDAN ÇIKAN RADYASYONUN AYNI ALANDA ÇALI AN BA KALARINI ETK LEMEMES Ç N KAYNAK YAPILAN ALANI ANT -REFLEKS PERDELER LE ÇEV R N. B) NEML ALANLARDA KAYNAK YAPMAYIN. C) KAYNAK TELLER NDEK LETKEN N AÇI A ÇIKIP ÇIKMADI INI KONTROL ED N. ÇIKMI SA DE T R N. D) KISA DEVRE OLU MASI YA DA ARKIN KAZAYLA DEVREYE G RMES R SK N ÖNLEMEK Ç N, ELEKTROD MANDALLARINI YA DA TORÇU DO RUDAN KAYNAK TEZGAHINA YA DA GÜÇ KAYNA INA BA LI METAL YÜZEYLER ÜZER NE KOYMAYIN. E) KAYNAK SIRASINDA Y HAVALANDIRILMI ORTAMLARDA ÇALI ILMASI VEYA DUMAN ASP RATÖRLER KULLANILMASI TAVS YE ED L R. F) BOYALI, GRESL VEYA YA LI PARÇALAR ÜZER NDE KAYNAK LEM YAPMAYIN. G) YEN KAYNAKLANMI PARÇALARI TUTARKEN D KKATL DAVRANIN. KAYNAK LEM SIRASINDA A IRI ISINAN PARÇALARIN YANI A NEDEN OLMAMASI Ç N BU PARÇALARI UYGUN MANDALLARLA TUTUN.
H) YANICI VE PARLAYICI MADDELER N YANINDA HERHANG B R LEM YAPMAKTAN KAÇININ. I) DAHA ÖNCE Ç NDE PARLAYICI MADDELER BULUNAN VAR LLERDE, METAL KAPLARIN Ç YÜZEY NDE YA DA HAVALANDIRMASI ZAYIF OLAN YERLERDE KAYNAK LEM YAPARKEN ÖZELL KLE D KKATL OLUN. BU LEMLER YAPILIRKEN DENEY ML PERSONEL DA MA YARDIMCI OLMALIDIR. L) SESTEN KORUNMA SESLE LG L OLARAK, 15 A USTOS 1991 TAR H VE 277 SAYILI KANUN KUVVET NDE KARARNAME HÜKÜMLER LE 80/1107/EEC, 82/65/EEC, 83/477/EEC, 86/188/EEC VE 88/642/EEC SAYILI YÖNETMEL K HÜKÜMLER YÜRÜRLÜKTED R. ARK KAYNA I VE PLAZMA KESME LEMLER NDE KULLANILAN ELEKTRON K EK PMANIN ÜRETT GÜRÜLTÜ NORMAL ARTLARDA 80 DBA DAN FAZLA DE LD R. UYGULANAN PROSESE GÖRE (DO AL YA DA DARBEL EK LDE T J KAYNA I) VE LG L KULLANIM KO ULLARINA GÖRE (KAYNAK VEYA KESME PARAMETRELER N N YO UNLU U, -TORÇ MESAFES, KAPALI YA DA AÇIK ORTAM) SES BU L M TTEN FAZLA OLAB L R. KULLANICILARIN KANUN HÜKÜMLER NE GÖRE HAREKET ETMELER GEREKMEKTED R. TEHL KE ARETLER GENELL KLE GÜÇ KAYNA ININ Ç NE YA DA DI INA YERLE T R LEN BAZI ARETLER MAK NEN N BU BÖLÜMÜNDE MEVCUT OLAB LECEK R SKLER GÖSTER R. BU ARETLER N ANLAMI A A IDA BEL RT LM T R: KULLANIM KILAVUZUNU D KKATLE OKUYUN GENEL ARET: GEREK NSANLAR GEREKSE NESNELER Ç N TEHL KE MEVCUT OLAB LECE N GÖSTER R. D KKAT! BU NOKTAYA DOKUNULMASI LEZYONLARA NEDEN OLAB L R. YANGIN TEHL KES : BU ARET N GÖSTER LD YERDE YANGIN MEYDANA GELEB L R. PATLAYICI MADDE VEYA PATLAMA TEHL KES ÖNSÖZ KÖRLÜK TEHL KES : BU ARET GÖRÜLDÜ ÜNDE KORUYUCU GÖZLÜK TAKILMALIDIR. ÖLÜM TEHL KES : BU ARET N GÖRÜLDÜ Ü YERDE ÇOK D KKATL OLUNMALIDIR. ÖLÜME NEDEN OLAB LEN B R KAZA MEYDANA GELEB LECE NDEN, BU ARET N GÖRÜLDÜ Ü PARÇALARA ASLA DOKUNULMAMALIDIR. BU MANUEL KULLANICIYA GÜÇ KAYNA ININ LET LMES LE LG L BAZI TAL MATLAR VERMEK VE BU KONUDA AÇIKLAMALAR YAPMAK AMACIYLA HAZIRLANMI TIR. BU MANUEL N AMACI GÜÇ KAYNA I LE YAPILAN ÇALI MALARI KOLAYLA TIRMAK OLUP, A A IDAK BÖLÜMLER OKURKEN D KKAT EDECE N Z G B, GÜÇ
KAYNA INA NORMAL USULLERLE BAKIM YAPILMASINA GEREK OLMADI INDAN, BU MANUEL B R BAKIM K TABI N TEL N TA IMAMAKTADIR. ALINACAK YEGANE ÖNLEM ELEKTR KL MAK NELERLE LG L OLANLARDIR (TOPRAKLAMA). AYRICA, GÜÇ KAYNA ININ SERT DARBELERE KAR I KORUNMASI, NAKL YE SIRASINDA OLA AN D KKAT N GÖSTER LMES, HASARA KAR I KORUNMASI VE A IRI SICAKLIKLARA MARUZ BIRAKILMAMASI GEREKMEKTED R. HERHANG B R ARIZA MEYDANA GELD TAKT RDE, YAPILACAK BAKIM SERV SLER VE ONARIMLARLA LG L OLARAK ELEKTRON K MÜHEND SLER N N BULUNDU U B R SERV S VEYA ONARIM MERKEZ NE BA VURULMASINI YA DA D STR BÜTÖRÜMÜZE HABER VER LMES N TAVS YE EDER Z. GÜÇ KAYNA I BA LANTISINI YAPMADAN ÖNCE JENERATÖR BA LANTISINI YAPMADAN VE JENERATÖRÜ AÇMADAN ÖNCE, KULLANIM KILAVUZUNU D KKATLE OKUYUN. BU EK LDE JENERATÖRÜN YANLI MONTE ED LMES VE ARIZALANARAK SATI SONRASI GARANT HAKLARININ KAYBED LMES ÖNLENM OLUR. HER EYDEN ÖNCE, TEM Z HAVA G R N N H ÇB R EK LDE ENGELLENMEM OLMASINA D KKAT ED LMEL D R. 1) GÜÇ KAYNA I AMBALAJINI AÇIN. 2) GÜÇ KAYNA INI DUVARA YASLAYARAK YA DA HAVA AKIMINI ENGELLEYECEK B R POZ SYONDA YERLE T RMEMEYE D KKAT ED N. ÖRNE N, GÜÇ KAYNA INI ÖRTÜ, BEZ, KA IT, NAYLON G B MADDELERLE ÖRTMEY N. 3) HAVA ISISININ 40 DERECEN N ALTINDA VE ÇEVREN N: A) AS T YA DA TUZLA KARI MI TOZLU VE NEML HAVA B) ÇOK M KTARDA DEM R VEYA METAL TOZU ÇEREN HAVA LE A IRI DÜZEYDE K RLENMEM OLMASINA D KKAT ED LMEL D R. 4) EBEKE GER L M N N KULLANILAN JENERATÖR T P LE UYUMLU OLUP OLMADI I KONTROL ED LMEL D R. 5) MEVCUT EBEKE GÜÇ DE ER N N MAK NEN N DÜZGÜN ÇALI MASI Ç N UYGUN OLUP OLMADI INI KONTROL ED N. KU KUNUZ VARSA, TEKN K B LG TABLOSUNA BAKIN. 6) BU GÜÇ KAYNAKLARINDA IP23 KORUMA DÜZEY BULUNMAKTADIR. DOLAYISIYLA, ÇAPI 12 MM.DEN BÜYÜK OLAN HAR C C S MLER VE DÜ EYDE 60 DERECEYE KADAR OLAN SU SIÇRAMALARINA KAR I KORUMA SA LAMAK Ç N BU ARTNAMEYE UYGUN DAVRANILMASI GEREK R. DOLAYISIYLA, A) KAYNAK MAK NELER N N HERHANG B R SIVIYA BATIRILMASINDAN B) KAYNAK MAK NELER N N ÇAMURLU VE ISLAK YÜZEYLERE KONULMASINDAN C) HAVA G R LER NE YABANCI C S M KONULMASINDAN KAÇINILMALIDIR. 7) KAYNAK MAK NES N MAHFAZASI OLMADAN KULLANMAYIN. BU DURUM GEREK MAK NE GEREKSE OPERATÖR Ç N TEHL KEL OLAB L R. GENEL [ ] SPES F K OLARAK HIZLI VE GÜVEN L R LEM YAPILMASININ STEND ENDÜSTR YEL UYGULAMALAR Ç N TASARLANMI B R PLAZMA KESME GÜÇ KAYNA IDIR. GÜÇ KAYNA I BU AMACA YÖNEL K OLARAK MAL ED LM T R. YEN NVERTER TEKN N N UYGULANMASI, ZOLASYONLU YÜZEYLER N KES LEB LMES NE VE BEKLENEN SONUÇLARIN ALINMASINA OLANAK TANIYAN KOMPAKT VE ÇOK HAF F B R C HAZIN MAL ED LEB LMES N MÜMKÜN KILMI TIR. [ ] BU C HAZ KURMA LER, ONARIMLAR VE AC L DURUMLARDAK (DEM RYOLLARI, OTOBÜS, OTOMOB L, TRAMVAY, VS.) UYGULAMALARIN YANI SIRA, AYNI ZAMANDA ÇEL K LEME ENDÜSTR S NDE, MAK NE ATÖLYELER NDE, GEM TERSANELER NDE DE UYGULAMA ALANI BULMU TUR. KES M Ç N YALNIZCA
BASINÇLI HAVANIN GEREKL OLMASI ÇOK ÖNEML B R AVANTAJ OLUP GAZ BULUNMAYAN YERLERDE KES M LEM YAPILAB LMES N SA LAR. [ ] IN ÇALI TI I YÜKSEK FREKANS (30 KHZ N ÜZER NDE) ELEKTROMEKAN K KESME MAK NELER N N T P K GÜRÜLTÜSÜNÜ ORTADAN KALDIRMAKTADIR. AYRICA, KUMANDANIN HIZLI REAKS YONU SAYES NDE, ELEKTR K ARKI KES M LEM N N GEREKS N MLER NE GÖRE HIZLA AYARLANAB L R. EBEKE GER L M NDEK OYNAMALAR VEYA YÜK DE MELER N N KES M AKIMI ÜZER NDE H ÇB R ETK S YOKTUR. [ ] GEL T R L RKEN, YÜKSEK TEKN K KAL TES N N YANI SIRA, UZUN ÖMÜRLÜ, SERV S GEREKS N M AZ OLAN VE YÜKSEK DÜZEYDE GÜVEN L R B R KESME GÜÇ KAYNA I OLU TURMAYA ÖZEN GÖSTER LM T R. [ ] IN VE PARÇALARININ MALATI Ç N GEREK GÜÇ DEVRES NDE GEREKSE KONTROL DEVRES NDE YALNIZCA SOL D ELEKTRON K B LE ENLER KULLANILMI TIR. ÇALI MADA MUTLAK GÜVEN L RL K SON DERECE ÖNEML D R VE BU HEDEFE ULA MAK Ç N B LE ENLER N YÜK ALTINDA T T ZL KLE TEST ED LMES GEREK R. ANCAK BU EK LDE, LER DE GÜÇ KAYNA ININ ARIZALANMASINA YOL AÇAB LECEK ÇOCUK HASTALIKLARI ADI VER LEN PROBLEM G DER LEB L R VE OLASI MALAT HATALARI ÖNLENEB L R. BU DURUMU GÖZ ÖNÜNE ALAN FIMER YALNIZCA GEREKEN DE ER N ÜZER NDE DE ERE SAH P B LE ENLER KULLANMAKLA KALMAMI, AYNI ZAMANDA KAL TE DÜZEY YÜKSEK PARÇALAR SEÇM T R. MONTAJDAN SONRA, NVERTER B RKAÇ GÜN SÜREYLE YÜK ALTINDA SIKI B R TESTE TAB TUTULUR. TEST SIRASINDA YÜK VE A IRI YÜK DURUMLARI S MÜLE ED LEREK OLASI ZAYIF VEYA HATALI KOMPONENTLER SAPTANAB L R VE DE T R LEB L R. MANTI I KULLANICI Ç N LG ÇEK C OLAB LECEK YEN B R MALAT TEKNOLOJ S N N UYGULANMASI [ ] TE BU OLA ANÜSTÜ ÖZELL KLER N TOPLANMASINI SA LAMI TIR. BLOK EMASI BLOK EMASINI TAR F ETMEDEN ÖNCE, [ ] MALATINDA ESAS ALINAN BAZI GENEL KAVRAMLARI AÇIKLAMAK STER Z. GÜÇ KAYNA ININ KALB, YAN [ ] IN TEKN K AÇIDAN EN GEL M KISMI ÜSTÜN KAL TEL ELEKTRON K B LE ENLERDEN YAPILMI OLAN VE ÇALI MA SIRASINDA YÜKSEK DÜZEYDE GÜVEN RL K SA LAYAN NVERTERD R. NVERTER, B R DC KAYNA INDAN BESLENEN VE STENEN FREKANSTA AC AKIM SA LAYAN ÖZEL B R OS LASYON DEVRES D R.
BU FREKANSI DE T REREK AYNI GÜÇ AKTARIMI Ç N DAHA KÜÇÜK VE DAHA HAF F TRAFOLARIN KULLANILMASI VE BURADA KESME AKIMINI FADE EDEN ANLIK ÇIKI DE KL KLER G B AVANTAJLAR SA LANAB L R. BU DURUM PROSES NE ADAPTE ED LEN VE HER AN DE EN B R AKIM VARYASYONU SA LAR. AYRICA, BU FREKANSLARIN UYGULANMASI ELEKTR K EK PMANINDA Y B L NEN VE RAHATSIZ ED C SESLER ORTADAN KALDIRIR. A- AC BESLEME GER L M REDRESÖR GRUBU TARAFINDAN REKT F YE ED L R VE SÜZÜLÜR (1). B- BU EK LDE ELDE ED LEN DC AKIM NVERTERDEN GEÇEREK YÜKSEK FREKANSLI AC AKIMA ÇEVR L R (2). C- BU AC AKIM ÇIKTININ EBEKEDEN GALVAN K OLARAK ZOLE ED LMES AMACIYLA B R ÜN TER ORANLI TRAFOYA (3) BESLEN R. D- TRAFO ÇIKI I YÜKSEK FREKANSLI B R GER L M BESLER VE BU GER L M GRUP (4) TARAFINDAN SÜZÜLEREK DC AKIMA ÇEVR L R. E- EBEKE BESLEME GER L M NOM NAL GER L ME (TR FAZE, 380V, ± %10) UYGUN OLMADI I TAKT RDE, KONTROL KARTI (5) BESLEME AKIMINI KESER. F- TAM OTOMAT K GÜÇ BESLEMES OLAN KONTROL PANEL N N (6) KONTROL VE ANINDA REAKS YON VE DENGELEME LEVLER BULUNMAKTADIR VE BU PANEL ÜZER NDE: 1) KESME AKIMINI KONTROL EDEN B R DÜ ME; 2) GÜÇ KAYNA ININ DURUMUNU GÖSTEREN GÖSTERGE LAMBALARI; 3) HAVA AKIMINI KONTROL EDEN ANAHTAR YER ALMAKTADIR. TEKN K B LG LER NVERTER PLAZMA 40 A G R GER L M FREKANS MAKS MUM PR MER AKIM MAKS MUM G R GÜCÜ GÜÇ KAYNA I 230 V (MONOFAZE) 50/60 HZ 15 AMP 3.2 KVA GÜÇ FAKTÖRÜ ( 1) 0.90 ETK NL K 0.80 KESME AKIMI REGÜLASYON ARALI I P LOT ARK AKIMI KESME 8/40 Amp 15 Amp ÇEVR M %60 40 Amp %100 25 Amp BOYUTLARI (GEN L K X DER NL K X YÜKSEKL K) A IRLIK KORUMA SINIFI 13x29x25 7 KG IP23
ÇEVR M 1) ÇEVR M GRAF N ORD NATINDA AMPER C NS NDEN KAYNAK AKIMI (IOUT) GÖSTER LMEKTED R; ABS S SE KULLANILAN TOPLAM ZAMANIN YÜZDES (%) GÖSTER LMEKTED R. %100 KES NT S Z FONKS YONU, %50 SE AYNI FONKS YON VE DURMA SÜRELER N GÖSTER R. DOLAYISIYLA, BU MAK NE TOPLAM ZAMANIN EN FAZLA %35 N KULLANARAK MAKS MUM AKIMI VEREB L R. BU AKIM KES NT S Z ÇALI MADA 30 A E DÜ ER. PLAZMA 70 100 SIRA NO. AÇIKLAMA 01 02 03 04 05 06 07 08
1: BU ANAHTAR LE TORÇTAN ARK OLMAKSIZIN HAVA AKIMININ SA LANMASI MÜMKÜNDÜR. ÖRNE N BLÖF ED L RKEN TORÇUN SO UTULMASI VE DEVREDE HAVA VARLI ININ KONTROL ED LMES ÇOK YARARLI OLACAKTIR. TORÇ BA LANTISI TORÇ, GAZ BA LANTISI, TORÇ BUTONU VE TORÇ Ç N ELEKTR K BA LANTISI ÇEREN B R PRAT K KONNEKTÖR LE KOLAYLIKLA BA LANAB L R. KES LECEK E BA LANACAK K TLE Ç N ÖN PANELDEK PARÇAYA B R MANDAL BA LANACAKTIR. KESME GAZI DEVRES PLAZMA KESME LEM NDE GEREK ARK BLÖFLEME GEREKSE TORÇ SO UTMA LEMLER NDE BASINÇLI HAVA KULLANILMAKTADIR. HAVA DEVRES 5 BAR BASINCA KAL BRE ED LM B R BASINÇ REGÜLATÖRÜ ÇER R (KAL BRASYON 5 BAR DAN FAZLA OLDU U TAKT RDE TORÇUN PNÖMAT K EMN YET TERT BATI KIRILIR). KESME ARKI OLU TURULURKEN K NC B R ELEKTROVALF AÇILARAK ANA HAVA AKIMININ GEÇMES N SA LAR. BU VALF YALNIZCA ÖN AKI, ART AKI, KESME LEM SIRASINDA ELEKTRON K MANTIK DEVRELER TARAFINDAN GEREKEN EK LDE YÖNLEND R LMES YA DA KONTROL PANEL ÜZER NDEK GAZ TEST ANAHTARI TARAFINDAN DO RUDAN YÖNLEND R LD TAKT RDE HAVANIN GEÇMES NE Z N VER R. EBEKE BA LANTISI VE ÇALI TIRMA GÜÇ KAYNA INI EBEKEYE BA LAMADAN ÖNCE, BESLEME GER L M N N MAK NE GER L M LE UYUMLU OLUP OLMADI I KONTROL ED LMEL D R. TR FAZE VERS YONDA, EBEKE GER L M 325 VE 440 VAC ARASINDA OLMALIDIR. TOPRAKLI BA LANTI YAPILMASI ZORUNLUDUR KORUMA S STEMLER JENERATÖRLERDE DA MA LEMLER N GEREKEN EK LDE YAPILMASINI SA LAYAN DAH L KORUMA TERT BATLARI BULUNMAKTADIR: A) MAKS MUM EBEKE GER L M KORUMASI. B) TERM K KORUMA. C) DAH L S GORTA. A) BESLEME GER L M N N MAKS MUM DE ER JENERATÖRLER BESLEME HATTINDA ANORMALL KLER OLU MASI HAL NDE MEYDANA GELEB LECEK DÜZENS ZL KLERE KAR I KORUNMU TUR. EBEKE DE ER 440 VAC N N ÜZER NE ÇIKARSA, JENERATÖR BLOKE OLUR VE BU FONKS YON ÖN PANELDEK LED4 LE GÖSTER L R. EBEKE GER L M OLMASI GEREKEN DÜZEYE DÜ ÜNCEYE KADAR LED BU POZ SYONDA KALIR. DAHA SONRA OTOMAT K OLARAK BLOKAJ KALKAR. B) TERM K KORUMA JENERATÖR -20 VE +40 C ARASINDAK ISILARDA ÇALI ACAK EK LDE KORUNMU TUR. KULLANIM YÜZDELER B LG TABLOSUNDA GÖRÜLEB L R. ISININ VEYA ÇEVR M N N BU SAB T L M TLER N ÜZER NE ÇIKMASI HAL NDE,
JENERATÖRÜN STRATEJ K BÖLÜMÜNE YERLE T R LM OLAN TERM K SENSÖRLER DURACAKTIR VE BUNUN SONUCU OLARAK LED (LED 4) YANAR (LED2 VEYA L2). ARTLAR NORMALE DÖNÜNCE JENERATÖR TEKRAR ÇALI MAYA BA LAR. C) DAH L S GORTALAR BU JENERATÖRLERDE PI200 BORDUNA YERLE T R LM 0.5 A DAH L S GORTA BULUNMAKTADIR. NOT: S GORTA DE T R LD KTEN SONRA JENERATÖRE YOL VER LD NDE S GORTA TEKRAR ATTI I TAKT RDE, JENERATÖRÜN Ç NDE B R ARIZA OLAB L R. DOLAYISIYLA, BU DURUMDA DO RUDAN FIMER N RONCO BRIANTINO DAK (MI) GENEL MERKEZ NE VEYA SATI SONRASI SERV S M ZE BA VURMANIZ GEREK R. TORÇ EMN YET [ ] JENERATÖR TORÇUNDA OPERATÖRÜN ELEKTR K ENERJ S YÜKLÜ PARÇALARLA TEMAS ETMES N ÖNLEYECEK EMN YET TERT BATI BULUNMAKTADIR. ELEKTRODA ULA MAK Ç N ZOLASYONLU TERM NAL N V DASI SÖKÜLDÜ ÜNDE LG L DEL KLERDEN DI ARI HAVA ÇIKAR VE BU DA PNÖMAT K EMN YET DEVRES NDE BASINÇ DÜ MES NE YOL AÇAR. BU BASINÇ DÜ MES N ALGILAYAN BASINÇ SENSÖRÜ (BASINÇ SV Ç ) JENERATÖRÜ DURDURUR VE BUNU ÖN PANELDEK LED (LED3) LE GÖSTER R. D KKAT!!! TORÇ LG L KONNEKTÖRE BA LANMADI I TAKT RDE, JENERATÖR ÇALI MAZ. BASINÇ 7.5 BAR IN ÜZER NDEYSE DEVRE ÇALI MAZ. TORÇ DEVREYE G RD NDE JENERATÖRÜ KAPATIN. ÇALI TIRMA [ ] IN ÇALI TIRILMASI ARK UZUNLU UNDAN BA IMSIZ OLARAK SEÇ LEN DE ERE E T SAB T B R AKIMIN BESLENMES KAVRAMINA DAYANIR. TORÇ BA LANTISI YAPILDIKTAN SONRA GÜÇ KAYNA I AÇILINCA P LOT HAVA AKIMI MEYDANA GEL R; 1 AÇILARAK ANA HAVANIN VARLI ININ KONTROL ED LMES ÖNER L R. BU DURUMDA AKIM DE ER M1 DÜ MES ÇEVR LEREK 20 VE 80 AMP ARASINDA B R DE ERE AYARLANAB L R. KESME LEM NE BA LAMAK Ç N TORÇU HERHANG B R C SME YÖNELTMEMEYE D KKAT EDEREK TORÇ ÜZER NDEK BUTONA BASILMASI YETERL OLACAKTIR. KES M LEM SIRASINDA TORÇ GEREKL HERHANG B R SÜRE Ç N ÇALI MA YÜZEY NDEN YUKARIDA TUTULAB L R. MÜMKÜN OLSA B LE LE D REKT TEMAS ÖNER LMEZ. ARK UZUNLU U 6-7 MM DEN FAZLA OLAMAZ. KESME LEM TAMAMLANDI INDA BUTON SERBEST BIRAKILIR VE ARK KES L R. TORÇUN SO UTULMASI Ç N YAKLA IK 10 SAN YE SÜREYLE ANA HAVA AKIMI VER L R (ARTÇI HAVA AKIMI) VE BU SIRADA P LOT HAVA AKI I DEVAM EDER. KESME HIZI METAL KESME LEMLER NDE UYGULANACAK KESME HIZI A A IDA BEL RT LEN ÇE TL PARAMETRELERE BA LIDIR: A) MALZEMEN N KALINLI I VE B LE M ; B) SEÇ LEN KESME AKIMI; C) KES LECEK HATTIN GEOMETR K ÖZELL (DO RU VEYA E R ).
KESME AKIMININ DE ER TEM Z B R KES M AÇISINDAN BÜYÜK ÖNEME SAH PT R. DOLAYISIYLA, AKIMIN GEREKEN EK LDE AYARLANMASI GEREK R. Y AYARLANMI B R KESME AKIMI ÇOK NET VE TEM Z B R KES M SA LAYACAKTIR. DEAL KES MLER YAPAB LMEK Ç N GEREKL BAZI TEMEL GÖSTERGELER A A IDAK TABLODA YER ALMAKTADIR. TABLODA YER ALAN ÖZELL KLER YUMU AK ÇEL K, ALÜM NYUM VE PASLANMAZ ÇEL KTE Y B R KES M ELDE EDEB LMEK Ç N GEREKL OLAN M N MUM VE MAKS MUM HIZLAR GÖSTER LMEKTED R. BU B LG LER YALNIZCA REHBER AMACIYLA VER LM OLUP [ ] LE ÇALI AN HER OPERATÖR DENEY MLER NE DAYANARAK HT YAÇLARI Ç N EN UYGUN OLAN LETME PARAMETRELER N BEL RLEYECEKT R. NVERTER PLAZMA TP 32 KESME HIZI KALINLIK mm. MALZEME AKIM Amp. KESME HIZI m/dak 0.4 YUMU AK ÇEL K 8 4.10 0.6 YUMU AK ÇEL K 10 3.25 1.5 YUMU AK ÇEL K 20 2.10 3.0 YUMU AK ÇEL K 30 1.05 6.0 YUMU AK ÇEL K 30 0.65 8.0 YUMU AK ÇEL K 40 0.25 0.8 ALÜM NYUM 10 3.60 1.5 ALÜM NYUM 20 2.15 3.0 ALÜM NYUM 30 1.30 6.0 ALÜM NYUM 30 0.45 8.0 ALÜM NYUM 40 0.20 0.4 PASLANMAZ ÇEL K (INOX) 10 3.60 0.6 PASLANMAZ ÇEL K (INOX) 12 2.60 1.5 PASLANMAZ ÇEL K (INOX) 20 1.35 3.0 PASLANMAZ ÇEL K (INOX) 30 0.85 6.0 PASLANMAZ ÇEL K (INOX) 30 0.55 8.0 PASLANMAZ ÇEL K (INOX) 40 0.25
PLAZMA INVERTER TP 32
TORÇ S 74 (00354) POS KOD AÇIKLAMA EURO 043,600,354 TORÇ MERKEZ BA LANTI 500 01 001,499,553 SV Ç 4 02 043,664,161 STANDART NOZÜL 6 03 043,664,160 KORUYUCU BA LIK 20 04 043,664,160L PLAST K ARA PARÇASI 3 05 043,664,151 YAY ARA PARÇASI 3 06 043,664,150 HAVA M L 15 07 043,664,150L STANDART ELEKTROD 6 08 043,662,863 FIRDÖNDÜ B LEZ 26 09 043,662,754 2 P ML ARA PARÇASI 8 10 043,662,875 4 P ML ARA PARÇASI 10 11 043,600,905 KOMPLE K T MASDAR 120 12 043,664,900 AKI ÖLÇER 9 13 043,664,900 ÇARK ARA PARÇASI 16