EPSTEIN-BARR VİRUS VİRAL KAPSİD ANTİKORLARININ SAPTANMASINDA İMMÜNOBLOT YÖNTEMİNİN DEĞERLENDİRİLMESİ

Benzer belgeler
EPSTEIN-BARR VİRUS ENFEKSİYONLARI TANISINDA ELISA VE İMMUNOBLOT TESTLERİNİN KARŞILAŞTIRILMASI

FLORA 2018;23(3): doi: /flora.66867

EBV Serolojik Tanısında Atipik Profil Sorunu

Soylu M Zeytinoğlu A Altuğlu İ Ege Üniversitesi Tıp Fakültesi, Tıbbi Mikrobiyoloji Anabilim Dalı, İzmir, Türkiye

VİRUS HASTALIKLARINDA TANI YÖNTEMLERİ

Epstein-Barr Virüs İnfeksiyonunun Tanısında İndirekt İmmünoflöresan ve ELİSA Tanı Metodlarının Karşılaştırılması

HIV TANISINDA YENİLİKLER

Epstein-Barr Virus Enfeksiyonlarının Tanısında PCR Sonuçlarının Değerlendirilmesi*

IV. KLİMUD Kongresi, Kasım 2017, Antalya

Ekinokokkozis. E. granulosus Kistik Ekinokokkozis. E. multilocularis Alveoler Ekinokokkozis. E. vogeli ve E. oligoarthrus Polikistik Ekinokokkozis

GİRİŞ. Kan dolaşımı enfeksiyonları (KDE) önemli morbidite ve mortalite sebebi. ABD de yılda KDE, mortalite % 35-60

Rekombinant Antijenler Kullanan Bir Enzim Immunassay Testinin Sifiliz Taraması İçin Değerlendirilmesi

TÜBERKÜLOZUN MOLEKÜLER TANISINDA GÜNCEL DURUM

KISA BİLDİRİ: KAN DONÖRLERİNDE HBsAg, ANTİ-HCV VE ANTİ-HIV ARAŞTIRILMASINDA İKİ FARKLI YÖNTEMİN KARŞILAŞTIRILMASI

Kocaeli Üniversitesi Tıp Fakültesi Çocuk Sağlığı ve Hastalıkları Anabilim Dalı. Çocuk Hematoloji BD Olgu Sunumu 4 Ocak 2018 Perşembe. Dr.

Serum ALT Düzeyleri, HCV RNA Ve Anti-HCV Arasındaki İlişki #

*Epstein-Barr Virus Antikorlar n n Araflt r lmas nda Kullan lan Paul-Bunnel Testi ve mmünblot Yönteminin Karfl laflt r lmas

Epstein-Barr virüs enfeksiyonlarında trombosit parametrelerinin değerlendirilmesi

TLERDE SEROLOJİK/MOLEK HANGİ İNCELEME?) SAPTANMASI

SİFİLİZ TANISINDA KULLANILAN SEROLOJİK TESTLER İÇİN AKIŞ ŞEMASININ OLUŞTURULMASI

Anti-HIV Pozitif Bulunan Hastada Kesin Tanı Algoritması. Doç. Dr. Kenan Midilli İ.Ü. Cerrahpaşa Tıp Fakültesi Tıbbi Mikrobiyoloji Anabilim Dalı

KISA BİLDİRİ: HEPATİT D VİRUS (HDV) RNA POZİTİFLİĞİ İLE HDV ANTİKORLARI ARASINDAKİ İLİŞKİNİN DEĞERLENDİRİLMESİ

Taramada Treponemal Test Kullanan Bir Sifiliz Tanı Algoritmasının Değerlendirilmesi

OTO-ANTİKORLARIN TANISINDA YENİ YÖNTEMLER

Yöntem ve Test Seçimine Yaklaşım. Dr. Alpay Özbek Mikrobiyoloji ve Klinik Mikrobiyoloji AD. Dokuz Eylül Üni. Tıp Fak. İZMİR

HIV TANISINDA YENİLİKLER

IV. KLİMUD Kongresi, Kasım 2017, Antalya

VİRAL MARKER PROGRAMI EKİM-2013 DÖNEMİ DEĞERLENDİRMESİ

CLOSTRIDIUM DIFFICILE ENFEKSİYONUNDA GLUTAMAT DEHİDROGENAZ VE TOKSİN A/B TESTLERİNİN TANI DEĞERİ VE MALİYET ETKİNLİĞİ

HIV/AIDS ve Diğer Retrovirus İnfeksiyonları,laboratuvar tanısı ve epidemiyolojisi

ve KARŞILAŞILAN SORUNLAR

SINIR DEĞERLER NE ÖNERİLİR? Düzen Laboratuvarlar Grubu

Hepatit C Virüsü: Tanıda Serolojik ve Moleküler Yöntemlerin Yeri. Üner Kayabaş İnönü Üniversitesi Tıp Fakültesi Malatya

Brusellozun serolojik tanısında yeni bir yöntem: İmmuncapture aglutinasyon testi

KISA BİLDİRİ: SALT ANTİ-HBc POZİTİF ÖRNEKLERDE OTOANTİKOR, ANTİ-HCV VE ANTİ-HIV SEROPOZİTİFLİĞİNİN ARAŞTIRILMASI*

Epstein-Barr Virüs (EBV) Enfeksiyonlarının Laboratuvar Tanısı. Dr.Saliha Sanem Geçgel

Gebelerde Anti HIV Sonuçlarının Değerlendirilmesi

Klinik Mikrobiyoloji de Enzimli İmmün Deney Enzyme Immuno Assay. Dr. Dilek Çolak

TRANSFÜZYON MERKEZİ HASTALARDA KULLANILAN MİKROBİYOLOJİK TARAMA TESTLERİ TALİMATI

MİKROBİYOLOJİK TARAMA TEST ÇALIŞILMA ESASLARI VE BAĞIŞÇI POZİTİFLİĞİNE YAKLAŞIM

Enterobacteriaceae Ġzolatlarında Karbapenemazların Saptanmasında Modifiye Hodge Testi ve Carba NP Testlerinin Karşılaştırılması

Klinik Mikrobiyoloji Laboratuarında Validasyon ve Verifikasyon Kursu 12 Kasım 2011 Cumartesi Salon C (BUNIN SALONU) Kursun Amacı:

SERVİKAL YETMEZİĞİNDE MCDONALDS VE MODDIFIYE ŞIRODKAR SERKLAJ YÖNTEMLERININ KARŞILAŞTIRILMASI

İMMUNOLOJİK TANI YÖNTEMLERİ

HCV İNFEKSİYONUNUNDA ELISA, RIBA VE b-dna YÖNTEMLERİNİN KARŞILAŞTIRILMASI

Ege Üniversitesi Tıp Fakültesi, Tıbbi Mikrobiyoloji Anabilim Dalı, İzmir, Türkiye

Uzamış Lenfadenopatili Çocuklarda EBV- DNA Saptanması

Yrd. Doç. Dr. Koray Ergünay MD PhD Hacettepe Üniversitesi Tıp Fakültesi Tıbbi Mikrobiyoloji AD. Viroloji Ünitesi

OLGULARLA KLİNİK VİROLOJİ (NORMAL İMMÜNİTE)

İNFEKSİYÖZ MONONÜKLEOZİS

Viral Hepatitler. Hepatit A Virus. Viral Hepatitler- Tarihsel Bakış. Hepatit Tipleri. Hepatit A Klinik Özellikler

KISA BİLDİRİ: BRUSELLOZUN TANISINDA BRUCELLACAPT TESTİNİN DEĞERİNİN ARAŞTIRILMASI

IFA TESTLERİNDE KALİTE VE GÜVENİLİRLİK. Dr. Derya Mutlu Akdeniz Üniversitesi Tıp Fakültesi Tıbbi Mikrobiyoloji Anabilim Dalı

Q HUMMASI İÇİN RİSK GRUPLARINDA COXIELLA BURNETII YE KARŞI OLUŞAN ANTİKORLARIN ELISA VE IFA TESTLERİ İLE SAPTANMASI

Prediktör Testler ve Sıradışı Serolojik Profiller. Dr. Dilara İnan Isparta

TANIMLAR. Dr. Neriman AYDIN. Adnan Menderes Üniversitesi Tıp Fakültesi Tıbbi Mikrobiyoloji Anabilim Dalı

Halis Akalın, Nesrin Kebabcı, Bekir Çelebi, Selçuk Kılıç, Mustafa Vural, Ülkü Tırpan, Sibel Yorulmaz Göktaş, Melda Sınırtaş, Güher Göral

Doç. Dr. Ahmet ALACACIOĞLU

VİRAL TANI KİTLERİ (GFJ-480)

Laboratuvar sonuçları ve sorunlar: IFA. Dr. Derya Mutlu Akdeniz Üniversitesi Tıp Fakültesi Tıbbi Mikrobiyoloji Anabilim Dalı

KENE KAYNAKLI ENSEFALİTLERDE LABORATUVAR TANI

HPV Moleküler Tanısında Güncel Durum. DNA bazlı Testler KORAY ERGÜNAY 1.ULUSAL KLİNİK MİKROBİYOLOJİ KONGRESİ

CMV lab.tanı Hangi test, ne zaman, laboratuvar sonucunun klinik anlamı?

Gebelikte İnfeksiyonların Değerlendirilmesi

Mardin Ýlinde Elektif Cerrahi Öncesi Tetkik Edilen Çocuklarda HBV, HCV ve HIV Seroprevalansý

Ege Üniversitesi Tıp Fakültesi Hastanesi ne Başvuran Hastalarda Varisella Zoster Virüs Serolojik Test Sonuçlarının Değerlendirilmesi

WEİL-FELİX TESTİ NEDİR NASIL YAPILIR? Weil Felix testi Riketsiyozların tanısında kullanılır.

İnci TUNCER S.Ü. Selçuklu Tıp Fakültesi Tıbbi Mikrobiyoloji Anabilim Dalı, KONYA

BOS, idrar, doku, diğer doku ve sıvılarda (DDS) Kalitatif testler (pozitif / negatif sonuç) Kantitatif testler (miktar belirten; viral yük)

Hepatit B Virüs Testleri: Hepatit serolojisi, Hepatit markırları

OTOANTİKORLARDA TANISAL METODOLOJİ. Doç. Dr. İlhan Afşar T.C. Sağlık Bakanlığı İzmir Katip Çelebi Üniversitesi Atatürk Eğitim ve Araştırma Hastanesi

Yasemin Budama Kılınç1, Rabia Çakır Koç1, Sevim Meşe2, Selim Badur2,3

P z o itif Nega g ti a f

Brusellozda laboratuvar tanı yöntemleri

Gebelerde Toxoplasma gondii Seropozitifliğinin Değerlendirilmesinde İstenen Testlerin Önerilen Tanı Algoritmasına Uygunluğunun Değerlendirilmesi

İmmünyetmezlikli Konakta Viral Enfeksiyonlar

Olgu Sunumu (İmmünyetmezlikli hastada viral enfeksiyonlar) Dr. A. Arzu Sayıner Dokuz Eylül Üniversitesi Tıp Fakültesi Tıbbi Mikrobiyoloji AD

21 gün. 21 gün. 21 gün. Tüm programlar için kullanılabilir. Tüm programlar için kullanılabilir. Tüm programlar için kullanılabilir.

KRONİK VİRAL HEPATİT C Lİ HASTALARDA IL28B NİN İNTERFERON TEDAVİSİNE YANITLA İLİŞKİSİ. Dr. Gülay ÇEKİÇ MOR

IMMUN FLORESAN TESTİ

İZMİR DEKİ GEBELERDE RUBELLA VE SİTOMEGALOVİRÜS İNFEKSİYONU SEROPREVALANSI RUBELLA AND CYTOMEGALOVIRUS INFECTION IN PREGNANTS IN IZMIR, TURKEY


Gebelik ve Enfeksiyonlar. Prof.Dr. Levent GÖRENEK

TOKSOPLAZMA İNFEKSİYONUNUN LABORATUVAR TANISI UZM.DR.CENGİZ UZUN ALMAN HASTANESİ

Araştırma. Demet Çelebİ*, Özgür Çelebİ**, Ülkü Altoparlak***, Ahmet Nezih Kök**** GİRİŞ

Moleküler Yöntemlerin Klinik Mikrobiyolojide Kullanımı Ne zaman? Nerede? Ne kadar? Klinik Parazitoloji

Postmenopozal Kadınlarda Vücut Kitle İndeksinin Kemik Mineral Yoğunluğuna Etkisi

Kış Sezonunda Görülen İnfluenza Virüsü Tipleri ve Tedavide Oseltamivir in Etkinliği

Gebelerde Rubella (Kızamıkçık) Yrd.Doç.Dr.Çiğdem Kader

Konjenital CMV Enfeksiyonu: Türkiye deki Durum

VİRÜS ENFEKSİYONLARDA LABORATUVAR TANISI

BELGELER. Dr. A. Arzu Sayıner Dokuz Eylül Üniversitesi Tıp Fakültesi Tıbbi Mikrobiyoloji AD

HIV/AIDS OLGULARINDA KIZAMIK, KIZAMIKÇIK, KABAKULAK VE SUÇİÇEĞİ SEROPREVALANSININ DEĞERLENDİRİLMESİ

Kırım Kongo Kanamalı Ateşi Virusunun Tüm Vücut Sıvılarında Saçılım Süresinin ve Serumda Antikor yanıtının moleküler ve serolojik olarak takibi

Kan Hizmetleri Genel Müdürlüğü

ABSTRACT $WWLWXGHV 7RZDUGV )DPLO\ 3ODQQLQJ RI :RPHQ $QG $IIHFWLQJ )DFWRUV

VERİFİKASYON. Dr. Tijen ÖZACAR. Ege Üniversitesi Tıp Fakültesi Tıbbi Mikrobiyoloji AD - İZMİR

CROSSMATCH ELISA YÖNTEMİ

BELGELER. Dr. A. Arzu Sayıner Dokuz Eylül Üniversitesi Tıp Fakültesi Tıbbi Mikrobiyoloji AD

ANTİ-HCV POZİTİF SERUM ÖRNEKLERİNDE VİREMİ ORANLARININ VE ANTİ-HCV DÜZEYLERİ İLE İLİŞKİSİNİN ARAŞTIRILMASI*

Transkript:

Özgün Çalışma/Original Article Mikrobiyol Bul 2010; 44: 231-236 EPSTEIN-BARR VİRUS VİRAL KAPSİD ANTİKORLARININ SAPTANMASINDA İMMÜNOBLOT YÖNTEMİNİN DEĞERLENDİRİLMESİ EVALUATION OF IMMUNOBLOT-BASED ASSAY FOR DETECTING EPSTEIN-BARR VIRUS VIRAL CAPSID ANTIBODIES İmre ALTUĞLU 1, Ayşegül AKSOY 1, Ayşın ZEYTİNOĞLU 1, Mehmet ORMAN 2 1 Ege Üniversitesi Tıp Fakültesi, Mikrobiyoloji ve Klinik Mikrobiyoloji Anabilim Dalı, İzmir. (imre.altuglu@ege.edu.tr) 2 Ege Üniversitesi Tıp Fakültesi, Tıbbi Bilişim ve Biyoistatistik Anabilim Dalı, İzmir. ÖZET Epstein-Barr virus (EBV) enfeksiyonlarının serolojik tanısında, immünofloresan (IFA) tekniklere alternatif olabilecek, uygulanması daha pratik ve değerlendirmesi daha objektif yeni alternatif yöntemler denenmektedir. Bu çalışmada, EBV viral kapsid antijenine karşı antikor varlığının (anti-vca IgM ve anti-vca IgG) saptanmasında immünoblot (IB) temelli bir testin, serolojik altın standart olarak kabul edilen IFA ile karşılaştırmalı performansının değerlendirilmesi amaçlanmıştır. Çalışmaya, Ege Üniversitesi Hastanesi Seroloji Laboratuvarına EBV enfeksiyonu serolojik durumunun saptanması amacıyla gönderilen yaşları 3 ay ile 89 yıl (ortalama 28 yıl) arasında değişen 104 kadın, 173 erkek hastaya ait 277 serum örneği alınmıştır. Tüm örnekler, IB (Euroline IgM ve IgG; Euroimmun, Almanya) ve IFA (EBV-CA IgG ve IgM, Euroimmun, Almanya) testleri ile çalışılmış ve sonuçlar phi (Φ) ilişki katsayısı kullanılarak karşılaştırılmıştır. IB yöntemiyle VCA IgM pozitif bulunan 216 olgunun sadece 34 (%15.7) ü IFA IgM ile doğrulanırken, 162 (%75) si IFA ile negatif, 20 (%9.3) si ise şüpheli olarak saptanmıştır (Φ= 0.167; düşük ilişki). Buna karşın IB yöntemiyle VCA IgG pozitif bulunan 85 olgunun 82 (%96.5) si IFA IgG ile doğrulanmış, 2 (%2.3) si negatif ve 1 (%1.2) i şüpheli olarak tespit edilmiş; IB ile negatif bulunan olguların %33.3 (6/18) ü IFA IgG ile de negatif sonuç vermiştir (Φ= 0.441; anlamlı ilişki). IFA ile alınan şüpheli sonuçlar değerlendirme dışı bırakıldığında; IB VCA IgG ile IFA IgG sonuçları arasındaki uyum %85.4 (88/103) ve IB VCA IgM ile IFA IgM sonuçları arasındaki uyum %27.3 (69/253) olarak hesaplanmıştır. IB VCA IgM yönteminde bantların reaksiyon şiddeti ile IFA IgM pozitifliği arasındaki ilişki incelendiğinde; IB testinde bant koyuluğu (1+ den 3+ e doğru) arttıkça IFA testindeki pozitiflik oranlarının da arttığı (p19 bandı için %9.9 dan %29.5 e; gp125 bandı için %24 ten %85.7) gözlenmiştir. IB VCA IgM testinde, 165 örnekte tek başına p19 bant pozitifliği belirlenmiş, bunlardan 135 (%81.8) inin IFA ile negatif, 15 (%9.1) inin pozitif ve 15 (%9.1) inin şüpheli sonuç verdiği izlenmiştir. IB temelli testler otomatize platformları ve bir serum örneğinde farklı IgG panellerinin saptanabilmesi gibi özellikleri nedeniyle IFA ya alternatif olmakla beraber, çalışmamızda VCA IgM testinde yalancı pozitiflik oranının oldukça yüksek olduğu (%75) gözlenmiştir. Sonuç olarak, tarama testi olarak IB yönteminin kullanıldığı rutin laboratuvarlarda, VCA IgM testi ile pozitif sonuç (özellikle de tek başına p19 bandı pozitifliği) veren örnekler ile düşük şiddette bant oluşturan örneklerin IFA ile doğrulanması gerektiği kanısına varılmıştır. Anahtar sözcükler: Epstein-Barr virus, immünoblot testi, immünofloresans testi, anti-vca antikorları. Geliş Tarihi: 26.10.2009 Kabul Ediliş Tarihi: 19.03.2010

Epstein-Barr Virus Viral Kapsid Antikorlarının Saptanmasında İmmünoblot Yönteminin Değerlendirilmesi ABSTRACT Various attempts have been made to improve Epstein-Barr virus (EBV) serodiagnosis by developing more practical and objective methods than immunofluorescence-based assays. In the present study, the performance of immunoblot-based assays were evaluated by comparing the results obtained by the gold standard immunofluorescence antibody (IFA) test for the detection of IgM and IgG antibodies against EBV viral capsid antigen (anti-vca). Serum samples of 277 patients admitted to Ege University Hospital for routine EBV diagnosis were included in the study. The age range of the patients was 3 months-89 years (mean 28 years) and 104 of them were females and 173 were males. All the samples were assayed by commercial immunoblot (Euroline IgM and IgG; Euroimmun, Germany) and IFA (EBV-CA IgG and IgM, Euroimmun, Germany) methods. Crosstabulation, chi-square test and phi (Φ) measures in SPSS 16.0 statistical package programme were used for data analysis. Of the 216 samples that were interpreted as positive with immunoblot-based IgM assay, only 34 (15.7%) were confirmed as positive with IFA, whereas 162 (75%) were negative, and 20 (9.3%) were equivocal (Φ= 0.167; low correlation). Of the 85 samples that were anti-vca IgG positive with immunoblot assay, 82 (96.5%) were positive, 2 (2.3%) were negative and 1 (1.2%) were equivocal with IFA (Φ= 0.441; significant correlation). When the indeterminate results obtained by IFA test were excluded from the evaluation, the correlation between immunoblot VCA IgG and IFA IgG was 85.4% (88/103) and between immunoblot VCA IgM and IFA IgM was 27.3% (69/253). When the intensities of bands were evaluated for IgM testing, it was noted that as the intensity of the bands increased (1+ to 3+), IFA VCA IgM reactivity rates increased (from 9.9% to 29.5% for p19 band; from 24% to 85.7% for gp125 band). For immunoblot VCA IgM testing, 165 samples were found to be positive only for VCA p19 band. Of these samples, 135 (81.8%) were negative, 15 (9.1%) were positive and 15 (9.1%) were equivocal with IFA. It is observed that even though immunoblot assays with automated blotting and scanning systems can be a convenient alternative to immunofluorescence assay, the rate of false positivity obtained for VCA IgM was high (75%). It was concluded that in laboratories which apply immunoblotting as a primary screening test for EBV serodiagnosis, the positive VCA IgM results (particularly isolated p19 band positivity) and the presence of low intensity bands, should be confirmed by IFA testing. Key words: Epstein-Barr virus, immunoblot test, immunofluorescence test, anti-vca antibodies. GİRİŞ İnsan Herpesvirus ailesinin üyelerinden biri olan Epstein-Barr virus (EBV) tüm dünyadaki erişkinlerin %95 ini enfekte etmektedir. EBV, akut ve kendini sınırlayan enfeksiyonlardan, Burkitt lenfoma ve nazofarenks karsinomu gibi malign neoplazmalara kadar çok geniş bir klinik hastalık spektrumuna sahiptir. EBV enfeksiyonlarının çoğu, çocukluk döneminde ve asemptomatik olarak geçirilir. Ancak enfeksiyonların semptomatik olduğu durumlarda, benzer semptomları oluşturan pek çok patojen olduğundan, EBV ile ilişkili enfeksiyöz mononükleoz tanısını koymak önemlidir 1,2. Akut enfeksiyöz mononükleozun tanısı, immün sistemi normal hastalarda EBV ye özgül antikorların saptanmasıyla konur 2,3. Antikor testlerinin spektrumu, özgül olmayan ve uzun süredir uygulanan heterofil antikor testlerinden, farklı substratlar, antijenler ve değerlendirme kriterlerine sahip EBV ye özgül yöntemlere kadar değişiklik göstermektedir. EBV enfeksiyonunda serolojik profilin belirlenmesinde özellikle üç serolojik parametrenin; viral kapsid antijeni (VCA) ne özgül IgG, VCA ya özgül IgM ve EBV nüklear antijen 1 (EBNA-1) e özgül IgG nin belirlenmesi önemlidir. EBV enfeksiyonunda oluşan hümoral yanıt, genellikle altın standart olarak kabul edilen indirekt immünofloresan (IFA) veya en- 232

Altuğlu İ, Aksoy A, Zeytinoğlu A, Orman M. zim immünassay (EIA) formatındaki testler ile değerlendirilir 4. Ancak özellikle IFA, çok fazla miktarda örneğin test edilmesine ve otomasyona olanak vermediğinden ve ayrıca, antijen çeşitliliği ve değerlendirmenin subjektif olmasına bağlı olarak standardizasyona uygun değildir. Bu amaçla, EBV enfeksiyonlarının serolojik tanısında IFA ya alternatif olabilecek yeni yöntemler denenmektedir 5,6. Bu çalışmada, immünoblot temelli bir testin anti-vca IgM ve IgG saptanmasında, serolojik altın standart olarak kabul edilen IFA ile karşılaştırmalı performansının değerlendirilmesi amaçlanmıştır. GEREÇ ve YÖNTEM Çalışmaya, Ege Üniversitesi Hastanesi Seroloji Laboratuvarına EBV enfeksiyonu serolojik durumunun saptanması amacıyla gönderilen, yaşları 3 ay ile 89 yıl (ortalama 28 yıl) arasında değişen 104 kadın, 173 erkek hastaya ait 277 serum örneği alındı. Örneklerde immünoblot (IB) testi, Euroline IgM (Euroimmun, Almanya) ve Euroline IgG (Euroimmun, Almanya) kitleriyle üretici firmanın önerileri doğrultusunda çalışıldı. Euroline IgM kiti ile, iki farklı EBV kapsid antijenine (gp125, p19) özgül IgM antikorları; Euroline IgG ile ise beş farklı EBV antijenine (VCA gp125, VCA p19, EBNA1 p22 ve EA- D) özgül IgG antikorları kalitatif olarak saptandı (Şekil 1). İşlemler Euroblot Master (Euroimmun, Almanya) cihazında gerçekleştirildi ve oluşan bantlar koyuluk şiddetine göre (+/-, +, ++, +++) derecelendirildi. Daha sonra aynı serum örnekleri, IFA temelli ticari bir test (EBV-CA IgG ve IgM, Euroimmun, Almanya) ile yine üretici firmanın önerilerine göre çalışılarak sonuçlar karşılaştı- VCA gp125 VCA p19 EBNA-1 p22 EA-D Kontrol Anti-VCA (gp125, p19) IgM pozitifliği enfeksiyonun erken dönemini; IgG pozitifliği yeni geçirilmiş (düşük aviditeli IgG) ya da önceden geçirilmiş (yüksek aviditeli IgG) enfeksiyonu gösterir. Anti-EBNA-1 pozitifliği, enfeksiyonun geç dönemlerinde saptanır ve önceden geçirilmiş enfeksiyonu gösterir. Nadiren bazı kişilerde sonradan negatifleşebilir (anti-ebna-1 kaybı). Anti-p22, enfeksiyonun geç dönemlerinde ortaya çıkar ve anti-ebna-1 kaybı olan hastalarda geçirilmiş enfeksiyonun ek bir belirleyicisi olarak kullanılır. Anti-EA-D, geçirilmekte olan/yeni geçirilen enfeksiyonu ifade eder. Şekil 1. İmmünoblot EBV-IgG ve EBV-IgM yönteminde kullanılan antijenler ve antikor pozitifliklerinin yorumlanması (Euroline EBV Profile 2, Euroimmun). 233

Epstein-Barr Virus Viral Kapsid Antikorlarının Saptanmasında İmmünoblot Yönteminin Değerlendirilmesi rıldı. Ayrıca, IgM ve IgG Euroline VCA p19 ve VCA gp125 bantlarının pozitiflik şiddeti ile IFA sonucu arasındaki ilişki değerlendirildi. Veri analizinde SPSS 16.0 programında çapraz tablo, ki-kare testi ve phi (Φ) ilişki katsayısı kullanıldı. BULGULAR Çalışılan serumlarda IB ve IFA yöntemleri ile alınan EBV IgM ve IgG sonuçları Tablo I de gösterilmiştir. IB yöntemiyle anti-vca IgM pozitif bulunan (p19 veya gp125 bandının tek başına veya birlikte pozitifliği) 216 olgunun sadece 34 (%15.7) ü IFA IgM ile de pozitif bulunurken, 162 (%75) si IFA ile negatif, 20 (%9.3) si ise şüpheli olarak saptanmıştır. Buna karşın IB ile anti-vca IgM negatif olarak bulunan 37 örneğin 35 (%94.6) i IFA IgM ile de negatif bulunmuştur (Tablo I). Yapılan değerlendirmede (IFA ile alınan şüpheli sonuçlar değerlendirme dışı bırakıldığında), IB VCA IgM ile IFA IgM sonuçları arasındaki uyum %27.3 (69/253) ve ilişki katsayısı düşük (Φ= 0.167) olarak saptanmıştır (Tablo I). Diğer taraftan, IB yöntemiyle anti-vca IgG pozitif bulunan 85 olgunun 82 (%96.5) si IFA IgG ile de pozitif olarak saptanırken; IB ile negatif bulunan 18 olgunun 6 (%33.3) sı IFA IgG ile de negatif sonuç vermiştir (Tablo I). Buna göre IB VCA IgG ile IFA IgG sonuçları arasındaki uyum %85.4 (88/103), ilişki katsayısı (Φ= 0.441) ise istatistiksel anlamlılık düzeyinde bulunmuştur. IB VCA IgM yönteminde bantların reaksiyon şiddeti ile IFA IgM pozitifliği arasındaki ilişki incelendiğinde; IB testinde bant koyuluğu (1+ den 3+ e doğru) arttıkça IFA testindeki pozitiflik oranlarının da arttığı (p19 bandı için %9.9 dan %29.5 e; gp125 bandı için %24 ten %85.7) gözlenmiştir. Tablo I. İmmünoblot ve IFA Yöntemleri ile Alınan EBV IgM ve IgG Sonuçlarının Karşılaştırılması IFA-IgM Negatif Pozitif Şüpheli* Toplam İmmünoblot VCA IgM Negatif 35 1 1 37 Pozitif 162 34 20 216 Toplam 197 35 21 253 IFA-IgG Negatif Pozitif Şüpheli* Toplam İmmünoblot VCA IgG Negatif 6 12 0 18 Pozitif 2 82 1 85 Toplam 8 94 1 103 * (+/-) olarak değerlendirilen sonuçlardır. 234

Altuğlu İ, Aksoy A, Zeytinoğlu A, Orman M. TARTIŞMA EBV enfeksiyonu serolojik tanısında rutin olarak uygulanan ve farklı teknikleri kullanan pek çok ticari yöntem bulunmaktadır 7-10. Bunlar arasında yer alan geleneksel testler olan IFA ve EIA, iyi tanımlanmış oldukça güvenilir testler olmakla beraber, çalışılan her parametre için ayrı ayrı örnek ve reaktife gereksinim duyulması, uygulanan her test için harcanan zaman ve iş gücünü artırmaktadır 11. IFA sonuçlarının değerlendirmesinin deneyim gerektirmesi ve subjektif olması da, bir başka dezavantaj olarak karşımıza çıkmaktadır. İmmünoblot (IB) yöntemleri ise, oldukça özgül olarak kabul edilen ve genellikle doğrulama amacıyla uygulanan yöntemlerdir 4. Bauer 12, rekombinant antijenlerin kullanıldığı IB yöntemlerinin EBV serolojisinde yeni bir altın standart olarak kabul edilebileceğini öne sürmüştür. Laboratuvarımızda yürütülen ve sınırlı sayıda örnekte yapılan bir başka çalışmada, IFA ve IB testleri arasındaki uyum, anti-ebna ve anti-vca IgM için güçlü, anti-ea ve anti-vca IgG için ise orta düzeyde saptanmıştır 13. Bu çalışmada, IB yöntemi ile VCA IgG pozitif sonuç veren örneklerin çoğunun (82/85; %96.5) IFA ile doğrulandığı görülmüştür. Buna karşın, IB ile VCA IgG negatif bulunan örneklerin %66.7 (12/18) si IFA ile pozitif olarak saptanmış ve alınan sonuçlar arasındaki bu farklılığın, kullanılan antijen sistemlerinin farklılığından kaynaklanabileceği düşünülmüştür. Zira, Euroline test stripleri natif VCA dan saflaştırılmış gp125 ve rekombinant VCA p19 antijenlerini içerirken; VCA IFA test lamlarında, her çukurcukta EBV kapsid antijenini eksprese eden hücreler kullanmaktadır. Dolayısıyla, özellikle IB ile atipik profil saptanan (örn. VCA IgG negatif, EBNA IgG pozitif) örneklerin, IFA ile tekrar çalışılmasının gerekliliği öngörülmüştür. Çalışmamızın bir diğer bulgusu, IB ile VCA IgM pozitif olarak bulunan 216 örneğin büyük çoğunluğunun (%84.3) IFA ile (162 negatif, 20 şüpheli sonuç) doğrulanmamış olmasıdır. IB ile VCA IgM pozitif sonuç veren örneklerin %76.4 (165/216) ünde pozitiflik tek başına p19 bandına bağlıdır. Bir bütün olarak Euroline VCA IgM pozitif olguların %75 (162/216) i ve izole p19 bandı pozitif örneklerin %81.8 (135/165) i, IFA ile tekrar test edildiğinde negatif olarak saptanmıştır. Dolayısıyla, IB ile VCA IgM pozitif olarak bulunan, özellikle de tek başına p19 bandında pozitif sonuç veren örnekler ile düşük şiddette bant oluşturan örneklerin IFA ile doğrulanması uygun olacaktır. Sonuç olarak, IB temelli testler, çok sayıda örneğin çalışılabilmesi, uygulama kolaylığı, otomatize platformları ve bir serum örneğinde farklı IgG panellerinin saptanabilmesi gibi özellikleri nedeniyle IFA ya alternatif oluşturmakla birlikte, çalışmamızda IB yönteminin IFA ile uyumluluk oranı VCA IgG için %85.4, VCA IgM için ise %27.3 olarak hesaplanmıştır. Çalışmamızın sınırlamaları arasında, IB ile alınan VCA IgG ve IgM negatif örnek sayılarının az olması ve örneklerde ELISA gibi bir başka yöntemin daha uygulanamamış olması sayılabilir. Yine de elde ettiğimiz veriler, tarama testi olarak IB yönteminin kullanıldığı rutin laboratuvarlarda, özellikle anti-vca IgM testi ile alınan pozitif sonuçların, yüksek yalancı pozitiflik oranı dikkate alınarak IFA ve/veya ELISA ile doğrulanması gerektiğini vurgulamaktadır. 235

Epstein-Barr Virus Viral Kapsid Antikorlarının Saptanmasında İmmünoblot Yönteminin Değerlendirilmesi KAYNAKLAR 1. Ooka T, Turenne-Tessier M, Stolzenberg MC. Relationship between antibody production to Epstein-Barr virus (EBV) early antigens and assessment. Springer Semin Immunopathol 1991; 13: 233-47. 2. Linde A. Epstein-Barr virus, pp: 1331-40. In: Murray, PR, Baron EJ, Jorgensen JH, Pfaller MA, Yolken RH (eds), Manual of Clinical Microbiology. 2003, 8 th ed. ASM Press, Washington DC. 3. Haque T, Crawford DH. Epstein-Barr virus, pp: 123-46. In: Zuckerman AJ, Banatvala JE, Schoub BD, Griffiths PD, Mortimer P (eds), Principles and Practice of Clinical Virology. 2009, 6 th ed. John Wiley and Sons Ltd, UK. 4. Hess RD. Routine Epstein-Barr virus diagnostics from the laboratory perspective: still challenging after 35 years. J Clin Microbiol 2004; 42: 3381-7. 5. Binnicker MJ, Jespersen DJ, Harring JA, Rollins LO, Beito EM. Evaluation of flow immunoassay for detection of Epstein-Barr virus specific antibodies. Clin Vaccine Immunol 2008; 15: 1410-3. 6. Farber I, Hinderer W, Rothe M, Lang D, Sonneborn HH, Wutzler P. Serological diagnosis of Epstein-Barr virus infection by novel ELISAs based on recombinant capsid antigens p23 and p18. J Med Virol 2001; 63: 271-6. 7. Buisson M, Fleurent B, Mak M, et al. Novel immunoblot assay using four recombinant antigens for diagnosis of Epstein-Barr virus primary infection and reactivation. J Clin Microbiol 1999; 37: 2709-14. 8. Debyser Z, Reynders M, Goubau P, Desmyter J. Comparative evaluation of three ELISA techniques and an indirect immunofluorescence assay for the serological diagnosis of Epstein-Barr virus infection. Clin Diagn Virol 1997; 8: 71-81. 9. Gartner BC, Fischinger JM, Roemer K, Mak M, Fleurent B, Mueller-Lantzsch N. Evaluation of a recombinant line blot for diagnosis of Epstein-Barr virus compared with ELISA, using immunofluorescence as reference method. J Virol Methods 2001; 93: 89-96. 10. Weber B, Brunner M, Preiser W, Doerr HW. Evaluation of 11 enzyme immunoassays for the detection of immunoglobulin M antibodies to Epstein-Barr virus. J Virol Methods 1996; 57: 87-93. 11. Baetens DG, Van Renterghem LM. Coupled particle light scattering: a new technique for serodiagnosis of Epstein-Barr virus infection. J Med Virol 2001; 64: 519-25. 12. Bauer G. Simplicity through complexity: immunoblot with recombinant antigens as new gold standard in Epstein-Barr virus serology. Clin Lab 2001; 47: 223-30. 13. Altuglu I, Bozkurt H, Samlioglu P, Zeytinoglu A. Evaluation of three different assays for the assessment of Epstein-Barr Virus immunological status. New Microbiologica 2007; 30: 393-8. 236